BS EN 50065-4-2-2002 Signalling on low voltage electrical installations in the frequency range 3 kHz to 148 5 kHz and 1 6 MHz to 30 MHz - Part 4-2 Low voltage decoupling filters - .pdf
《BS EN 50065-4-2-2002 Signalling on low voltage electrical installations in the frequency range 3 kHz to 148 5 kHz and 1 6 MHz to 30 MHz - Part 4-2 Low voltage decoupling filters - .pdf》由会员分享,可在线阅读,更多相关《BS EN 50065-4-2-2002 Signalling on low voltage electrical installations in the frequency range 3 kHz to 148 5 kHz and 1 6 MHz to 30 MHz - Part 4-2 Low voltage decoupling filters - .pdf(34页珍藏版)》请在麦多课文档分享上搜索。
1、 g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58frequency range 3 kHz to 148,5 kHz and 1,6 MHz to 30 MHz Part 4-2: Low voltage decoupling filters S
2、afety requirementsThe European Standard EN 50065-4-2:2001, with the incorporation of amendments A1:2003 and A2:2005, has the status of a British StandardICS 31.160; 33.040.30Signalling on low voltage electrical installations in the BRITISH STANDARDBS EN 50065-4-2:2002Incorporating Amendment Nos. 1 a
3、nd 2BS EN 50065-4-2:2002This British Standard, having been prepared under the direction of the Electrotechnical Sector Policy and Strategy Committee, was published under the authority of the Standards Policy and Strategy Committee on 24 January 2002 BSI 12 December 2005ISBN 0 580 38881 6A list of or
4、ganizations represented on this committee can be obtained on request to its secretary.Cross-referencesThe British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Corres
5、pondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard does not of
6、itself confer immunity from legal obligations.Summary of pagesThis document comprises a front cover, an inside front cover, the EN title page, pages 2 to 31 and a back cover.The BSI copyright date displayed in this document indicates when the document was last issued.Amendments issued since publicat
7、ionAmd. No. Date Comments14440 29 May 2003 See national foreword15775 12 December 2005 Change to title and see national foreword aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep th
8、e UK interests informed; monitor related international and European developments and promulgate them in the UK.National forewordThis British Standard is the official English language version of EN 50065-4-2:2001, including amendments A1:2003 and A2:2005.The start and finish of text introduced or alt
9、ered by amendment is indicated in the text by tags !“. Tags indicating changes to CENELEC text carry the number of the CENELEC amendment. For example, text altered by CENELEC amendment 1 is indicated by !“.The UK participation in its preparation was entrusted to Technical Committee PEL/205, Mains si
10、gnalling, which has the responsibility to: EUROPEAN STANDARD EN 50065-4-2 +A2 NORME EUROPENNE August 2001 April 2005 EUROPISCHE NORM +A1 January 2003 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnisc
11、he Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2001 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50065-4-2:2001 + A1:2003 + A2:2005 E ICS 31.160; 33.040.30 English version Signalling on low voltage electr
12、ical installations in the frequency range 3 kHz to 148,5 kHz and 1,6 MHz to 30 MHz Part 4-2: Low voltage decoupling filters - Safety requirements (includes amendments A1:2003 and A2:2005) Transmission de signaux sur les rseaux lectriques basse tension dans la bande de frquences de 3 kHz 148,5 kHz Pa
13、rtie 4-2: Filtres basse tension de dcouplage - Exigences de scurit (inclut les amendements A1:2003 et A2:2005) Signalbertragung auf elektrischen Niederspannungsnetzen im Frequenzbereich 3 kHz bis 148,5 kHz Teil 4-2: Niederspannungs-Entkopplungsfilter Sicherheitsanforderungen (enthlt nderungen A1:200
14、3 und A2:2005) This European Standard was approved by CENELEC on 2000-11-01. Amendment A1 was approved by CENELEC on 2002-12-01 and amendment A2 was approved by CENELEC on 2005-3-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for givi
15、ng this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official v
16、ersions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees
17、 of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EN 50065-4-2:2001 - 2 -
18、Foreword This European Standard was prepared by SC 205A, Mains communicating systems, of Technical Committee CENELEC TC 205, Home and Building Electronic Systems (HBES). This European Standard has been prepared under a mandate given to CENELEC by the European Commission and covers the essential requ
19、irements of the Low Voltage Directive 73/23/EEC. The text of the draft was submitted to the Unique Acceptance Procedure and was approved by CENELEC as EN 50065-4-2 on 2000-11-01. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an
20、identical national standard or by endorsement (dop) 2002-02-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2003-11-01 EN 50065 consists of the following parts, under the general title: Signalling on low voltage electrical installations in the freque
21、ncy range 3 kHz to 148,5 kHz Part 1 General requirements, frequency bands and electromagnetic disturbances Part 2-1 Immunity requirements for mains communications equipment and systems operating in the range of frequencies 95 kHz to 148,5 kHz and intended for use in residential, commercial and light
22、 industrial environments Part 2-2 Immunity requirements for mains communications equipment and systems operating in the range of frequencies 95 kHz to 148,5 kHz and intended for use in industrial environments Part 2-3 Immunity requirements for mains communications equipment and systems operating in
23、the range of frequencies 3 kHz to 95 kHz and intended for use by electricity suppliers and distributors Part 4-1 Low voltage decoupling filters Generic specification Part 4-2 Low voltage decoupling filters Safety requirements Part 4-3 Low voltage decoupling filters Incoming filter Part 4-4 Low volta
24、ge decoupling filters Impedance filter Part 4-5 Low voltage decoupling filters Segmentation filter Part 4-6 Low voltage decoupling filters Phase coupler Part 7 Equipment impedance #This safety standard EN 50065-4-2 has no frequency dependent content. It was originally conceived as a safety document
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN50065422002SIGNALLINGONLOWVOLTAGEELECTRICALINSTALLATIONSINTHEFREQUENCYRANGE3KHZTO1485KHZAND16MHZTO30MHZPART42LOWVOLTAGEDECOUPLINGFILTERSPDF

链接地址:http://www.mydoc123.com/p-574496.html