BS EN 50065-2-1-2003 Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148 5 kHz Immunity requirements for mains communications equipment and systet.pdf
《BS EN 50065-2-1-2003 Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148 5 kHz Immunity requirements for mains communications equipment and systet.pdf》由会员分享,可在线阅读,更多相关《BS EN 50065-2-1-2003 Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148 5 kHz Immunity requirements for mains communications equipment and systet.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS EN 50065-2-1:2003Incorporating Corrigendum No. 1 and Amendment No. 1Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz Part 2-1: Immunity requirements for mains communications equipment and systems operating in the range of frequencies 95
2、kHz to 148,5 kHz and intended for use in residential, commercial and light industrial environmentsThe European Standard EN 50065-2-1:2003, with the incorporation of amendment A1:2005, has the status of a British StandardICS 33.040.30g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g5
3、1g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 50065-2-1:2003This British Standard was published under the authority of the Standards Policy and Strategy Committee on 11 April 2003 BSI 7 March 2006ISBN 0 580
4、41580 5National forewordThis British Standard is the official English language version of EN 50065-2-1:2003, including Corrigendum August 2003 and amendment A1:2005.The start and finish of text introduced or altered by CENELEC amendment is indicated in the text by tags !“. Tags indicating changes to
5、 CENELEC text carry the number of the CENELEC amendment. For example, text altered by CENELEC amendment A1 is indicated in the text by !“.The UK participation in its preparation was entrusted to Technical Committee PEL/205, Mains signalling, which has the responsibility to: A list of organizations r
6、epresented on this committee can be obtained on request to its secretary.Cross-referencesThe British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Inde
7、x”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard does not of itself confer
8、 immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep UK interests informed; monitor related international and European developments and promulgate the
9、m in the UK.Summary of pagesThis document comprises a front cover, an inside front cover, the EN title page, pages 2 to 15 and a back cover.The BSI copyright date displayed in this document indicates when the document was last issued.Amendments issued since publicationAmd. No. Date Comments14800Corr
10、igendum No. 125 November 2003 Correction to Table 2, item b) Units column16002 March 2006 See national forewordEUROPEAN STANDARD EN 50065-2-1 +A1NORME EUROPENNE EUROPISCHE NORM January 2003September 2005 CENELECEuropean Committee for Electrotechnical Standardization Comit Europen de Normalisation El
11、ectrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2003 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50065-2-1:2003 + A1:2005 E ICS 33.040.30 Incorporating
12、 corrigendum August 2003English version Signalling on low-voltage electrical installationsin the frequency range 3 kHz to 148,5 kHz Part 2-1: Immunity requirements for mains communications equipment and systems operating in the range of frequencies 95 kHz to 148,5 kHz and intended for use in residen
13、tial, commercialand light industrial environments (includes amendment A1:2005)Transmission de signaux sur les rseaux lectriques basse tension dans la bande de frquences de 3 kHz 148,5 kHz Partie 2-1: Exigences dimmunitpour les appareils et les systmesde communication sur le rseau lectrique dans la b
14、ande de frquences de 95 kHz 148,5 kHz et destins tre utiliss dans les environnements rsidentiel, commercial et de lindustrie lgre(inclut lamendement A1:2005)Signalbertragung auf elektrischen Niederspannungsnetzenim Frequenzbereich 3 kHz bis 148,5 kHz Teil 2-1 : Strfestigkeitsanforderungenan Netz-Dat
15、enbertragungsgerteund -systeme, die im Frequenzbereich95 kHz bis 148,5 kHz betrieben werdenund fr den Gebrauch in Wohnbereichen, Geschfts- und Gewerbebereichensowie in Kleinbetrieben bestimmt sind (enthlt nderung A1:2005)This European Standard was approved by CENELEC on 2001-12-04; amendment A1:2005
16、 was approved by CENELEC on 2006-07-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning
17、such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its ow
18、n language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlan
19、ds, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United Kingdom. EN 50065-2-1:2003 2 Foreword This European Standard was prepared by SC 205A, Mains communicating systems, of Technical Committee CENELEC TC 205, Home and Building Electronic Systems (HBES). The text of the draft was submi
20、tted to the Unique Acceptance Procedure and was approved by CENELEC as EN 50065-2-1 on 2001-12-04. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2003-10-01 latest date by wh
21、ich the national standards conflicting with the EN have to be withdrawn (dow) 2004-10- 01 This part of this standard defines limits and test methods for the immunity of mains communication equipment and systems (MCES) operating in the range of frequencies from 95 kHz to 148,5 kHz and intended for us
22、e in residential, commercial and light industrial environments. Immunity requirements for similar equipment intended for operation in industrial environments are given in Part 2-2 of this standard. Immunity requirements and tests applicable to Electricity Suppliers equipment and systems operating in
23、 the band 3 kHz to 95 kHz are given in Part 2-3. These tests and limits represent essential electromagnetic compatibility and immunity requirements. Correspondingly not all known disturbances have been included for testing purposes which have been limited to those disturbances known to be critical f
24、or the operation of such equipment including specific MCES disturbances such as conducted narrow band. The immunity requirements have been selected to ensure an adequate level of immunity for MCES in residential, commercial and light industrial environments. The levels do not however cover extreme c
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN50065212003SIGNALLINGONLOWVOLTAGEELECTRICALINSTALLATIONSINTHEFREQUENCYRANGE3KHZTO1485KHZIMMUNITYREQUIREMENTSFORMAINSCOMMUNICATIONSEQUIPMENTANDSYSTETPDF

链接地址:http://www.mydoc123.com/p-574492.html