BS EN 14884-2005 Air quality - Stationary source emissions - Determination of total mercury automated measuring systems《空气质量 固定源排放 总汞含量的测定 自动测量系统》.pdf
《BS EN 14884-2005 Air quality - Stationary source emissions - Determination of total mercury automated measuring systems《空气质量 固定源排放 总汞含量的测定 自动测量系统》.pdf》由会员分享,可在线阅读,更多相关《BS EN 14884-2005 Air quality - Stationary source emissions - Determination of total mercury automated measuring systems《空气质量 固定源排放 总汞含量的测定 自动测量系统》.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS EN 14884:2005Air quality Stationary source emissions Determination of total mercury: automated measuring systemsThe European Standard EN 14884:2005 has the status of a British StandardICS 13.040.40g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g
2、54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58Licensed Copy: Wang Bin, na, Tue Apr 18 04:14:58 BST 2006, Uncontrolled Copy, (c) BSIBS EN 14884:2005This British Standard was published under the authority of the Standards Policy and
3、 Strategy Committee on 26 January 2006 BSI 26 January 2006ISBN 0 580 47719 3National forewordThis British Standard is the official English language version of EN 14884:2005. The UK participation in its preparation was entrusted by Technical Committee EH/2, Air quality, to Subcommittee EH/2/1, Statio
4、nary source emissions, which has the responsibility to:A list of organizations represented on this subcommittee can be obtained on request to its secretary.The UK, as a member of CEN, is obliged to publish EN 14884:2005 as a British Standard. However, attention is drawn to the fact that during the d
5、evelopment of this European Standard, the UK consistently voted against its approval as a European Standard.Total-mercury monitors commonly include a conversion system to convert all gaseous oxidized mercury into the elemental form. The performance of some of these conversion systems can be less tha
6、n ideal, for example, in sources with high concentrations of acid components (such as stacks with high SO2emissions). It is in the opinion of the UK committee that EN 14884:2005 does not provide sufficient practical guidance on how to deal with such problems. Therefore the UK recommends that EN 1488
7、4:2005 should be used in conjunction with the operator-manual for each Automated Measuring System (AMS) used. The user of EN 14884:2005 should obtain the necessary information from the AMS supplier to ensure a continuing, valid performance of the AMS in the specific stack conditions to which it is a
8、pplied.As identified in the scope, EN 14884:2005 is not applicable as a stand-alone document and is to be used in conjunction with EN 14181. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change,
9、 and keep UK interests informed; monitor related international and European developments and promulgate them in the UK.Summary of pagesThis document comprises a front cover, an inside front cover, page i, a blank page, the EN title page, pages 2 to 18, an inside back cover and a back cover.The BSI c
10、opyright notice displayed in this document indicates when the document was last issued.Amendments issued since publicationAmd. No. Date CommentsLicensed Copy: Wang Bin, na, Tue Apr 18 04:14:58 BST 2006, Uncontrolled Copy, (c) BSIBS EN 14884:2005iCross-referencesThe British Standards which implement
11、international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online.This publication does not
12、purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations.Licensed Copy: Wang Bin, na, Tue Apr 18 04:14:58 BST 2006, Uncontrolled Copy, (c) BSIblankLic
13、ensed Copy: Wang Bin, na, Tue Apr 18 04:14:58 BST 2006, Uncontrolled Copy, (c) BSIEUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 14884December 2005ICS 13.040.40English VersionAir quality - Stationary source emissions - Determination of totalmercury: automated measuring systemsQualit de lair - Emi
14、ssions de sources fixes -Dtermination de la concentration en mercure totale:systmes automatiques de mesureLuftbeschaffenheit - Emissionen aus stationren Quellen -Bestimmung der Gesamtquecksilber-Konzentration:Automatische MesseinrichtungenThis European Standard was approved by CEN on 28 November 200
15、5.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on a
16、pplication to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has
17、 the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovak
18、ia,Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2005 CEN All rights of exploitation in any form and by any means reservedworldwide for C
19、EN national Members.Ref. No. EN 14884:2005: ELicensed Copy: Wang Bin, na, Tue Apr 18 04:14:58 BST 2006, Uncontrolled Copy, (c) BSIEN 14884:2005 (E) 2 Contents Page Foreword 3 Introduction4 1 Scope .5 2 Normative references .5 3 Terms and definitions.5 4 Principle.6 5 AMS performance criteria for QAL
20、 1 .6 6 AMS location .7 7 Calibration and validation of the AMS (QAL2) 7 7.1 General 7 7.2 Calibration procedure.7 7.2.1 Parallel measurements with SRM 7 7.2.2 Automatic recording of AMS output signals.8 7.3 Establishing the calibration function 8 8 Ongoing quality assurance during operation (QAL 3)
21、 .8 9 Annual surveillance test (AST) 8 Annex A (informative) Example of calculation of the calibration function and of the variability test .9 A.1 General 9 A.2 Data evaluation .9 A.2.1 General 9 A.2.2 Calculation of measured values of the SRM at standard conditions11 A.2.3 Calibration function 12 A
22、.2.4 Calibrated values of AMS .13 A.2.5 Conversion of data to standard conditions 13 A.2.6 Valid calibration range14 A.2.7 Test of variability.15 Bibliography.18 Licensed Copy: Wang Bin, na, Tue Apr 18 04:14:58 BST 2006, Uncontrolled Copy, (c) BSIEN 14884:2005 (E) 3 Foreword This European Standard (
23、EN 14884:2005) has been prepared by Technical Committee CEN/TC 264 “Air quality”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by June 2006, and conflictin
24、g national standards shall be withdrawn at the latest by June 2006. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, F
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN148842005AIRQUALITYSTATIONARYSOURCEEMISSIONSDETERMINATIONOFTOTALMERCURYAUTOMATEDMEASURINGSYSTEMS

链接地址:http://www.mydoc123.com/p-572780.html