BS 3900-F2-1973 Methods of test for paint - Durability tests on paint films - Determination of resistance to humidity (cyclic condensation)《涂料试验方法 涂膜耐久性试验 耐湿性(循环冷凝)测定》.pdf
《BS 3900-F2-1973 Methods of test for paint - Durability tests on paint films - Determination of resistance to humidity (cyclic condensation)《涂料试验方法 涂膜耐久性试验 耐湿性(循环冷凝)测定》.pdf》由会员分享,可在线阅读,更多相关《BS 3900-F2-1973 Methods of test for paint - Durability tests on paint films - Determination of resistance to humidity (cyclic condensation)《涂料试验方法 涂膜耐久性试验 耐湿性(循环冷凝)测定》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD CONFIRMED JULY 1989 BS 3900-F2: 1973 (Reprinted, incorporating Amendment No. 1) Methods of Test for paints Part F2: Determination of resistance to humidity (cyclic condensation) It is recommended that this Part be read in conjunction with the general information in the Introduction
2、to BS 3900 issued separately (revised edition published March 1969). UDC 667.61 + 667.613.2:620.193.23BS3900-F2:1973 BSI 12-1999 ISBN 0 580 07109 X Foreword This Part of BS3900 was first published in1966 and is based on DEF-1053 Method No.25 “Resistance to humidity under condensation conditions”. Mo
3、re recently, with the implementation of ISO6270:1980 as BS3900-F9 “Determination of resistance to humidity (continuous condensation)”, it was decided that this Part of BS3900 should be retained for a limited period while there is still some requirement by users. While the two methods have some commo
4、n features, the method described in this Part is carried out using cyclic condensation conditions, and this is reflected in the difference in the titles. Because of the likelihood of the withdrawal of this Part following the decision by ISO not to accept this method, users are recommended to conside
5、r the adoption of the method described in PartF9. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obli
6、gations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages 1 and 2 and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cove
7、r. Amendments issued since publication Amd. No. Date of issue CommentsBS3900-F2:1973 BSI 12-1999 i Contents Page Foreword Inside front cover 1 Scope 1 2 Supplementary information 1 3 Apparatus 1 4 Sampling 1 5 Test panel 1 6 Procedure 2 7 Test report 2ii blankBS3900-F2:1973 BSI 12-1999 1 1 Scope Thi
8、s Part of BS3900 describes a procedure for determining the resistance to humidity under condensation conditions, induced by cyclic temperature changes between42 C and48 C, of a single coat film or multicoat system of paint, varnish or related product. 2 Supplementary information The method of test d
9、escribed below requires to be completed, for any particular application, by the following supplementary information. This information is to be derived from the British Standard or other document for the product under test or, where appropriate, is to be the subject of agreement between the parties t
10、o the test. 1) Material and surface preparation of substrate. 2) Method of application of test coating to substrate. 3) Thickness, in micrometres, of dry coating, including method of measurement in accordance with BS3900-C5 1)and whether it is a single coat film or a multicoat system. 4) Duration an
11、d conditions of drying of the coated panel before testing (or conditions of stoving and ageing, if applicable) before testing. 5) Duration of test. 6) How inspection of the test coating is to be made and what characteristics are to be considered in evaluating its resistance properties. 3 Apparatus 3
12、.1 The apparatus shall consist of a closed cabinet in which the relative humidity is maintained at approximately100% and the temperature is cycled continuously over the range42Cto48 C, thereby ensuring that copious condensation occurs on test panels positioned vertically within the cabinet. NOTEIf t
13、he cabinet is copper lined, the copper should be tinned or coated with a suitable organic coating to prevent the solution of small amounts of copper in the water. 3.2 The design and dimensions of the apparatus are left to the users discretion, provided that the following conditions are observed. 3.2
14、.1 Humidification. The humidity shall be maintained by evaporation of distilled water 2)from a reservoir covering (or situated in) the bottom of the cabinet. The water shall be maintained free from grease or oil. 3.2.2 Heating. The cabinet shall be heated through the medium of the water by a heater
15、placed immediately below the water reservoir or, alternatively, by a heater completely immersed in the water. 3.2.3 Temperature cycle. The heater shall be controlled by two thermostats (placed in the air space above the water) in such a way that the temperature of the air space is cycled continuousl
16、y from42 C to48 C and back to42 C in605minutes. The times required for heating and cooling shall be approximately equal. A recording thermometer is desirable for ensuring that the temperature cycle is correct. 3.2.4 Air circulation. The air in the cabinet shall be circulated by means of a fan in suc
17、h a way that the temperatures at any two points in the air space do not differ by more than1.0 C at any given moment. 3.2.5 Spacing of panels. With cabinets as usually constructed, it is inadvisable to place the panels less than40mm apart or less than40mm from any side of the cabinet. 3.2.6 Suspensi
18、on of panels. If the panels hang in the cabinet, it is essential that the hooks and rods from which they are suspended shall be made of glass or plastics material. If racks are used, the panels shall stand vertically and be suitably insulated from any metal parts. The position of the panels in the c
19、abinet shall be interchanged throughout the test period, once every24hours. NOTEThe cabinet should be opened only at intervals of24hours, for inspection of panels, maintenance of the water level, rotation of panels, etc. 4 Sampling A representative sample of the product to be tested (or of each prod
20、uct in the case of a multicoat system) shall be taken as described in BS3900-A1 3) . The sample(s) shall then be examined and prepared for testing as described in BS3900-A2 4) . 5 Test panel 5.1 Materials and dimensions. Unless otherwise specified or agreed the test panel shall be of burnished steel
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS3900F21973METHODSOFTESTFORPAINTDURABILITYTESTSONPAINTFILMSDETERMINATIONOFRESISTANCETOHUMIDITYCYCLICCONDENSATION

链接地址:http://www.mydoc123.com/p-543953.html