《ASTM F3031-2017 Standard Practice for Range of Motion Evaluation of First Responder&x2019 s Protective Ensembles《评估应急人员全身防护服活动度的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM F3031-2017 Standard Practice for Range of Motion Evaluation of First Responder&x2019 s Protective Ensembles《评估应急人员全身防护服活动度的标准实施规程》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F3031 17Standard Practice forRange of Motion Evaluation of First Responders ProtectiveEnsembles1This standard is issued under the fixed designation F3031; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of las
2、t revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONProtective ensembles such as firefighter turnout gear, HAZMAT suits, etc., may impose a negativeergonomic impact on the w
3、earer. This impact may involve restriction of movement and overalldiscomfort to the wearer. The possible increased restrictions of mobility during the use of protectiveensembles may result in injuries to the musculoskeletal system, decreased performance, and decreasedcomfort. It is up to the end use
4、r to decide the meaningfulness of the information provided with the useof this standard for the performance of his/her job. This ergonomic standard practice is to determineand report the range of motion (ROM) of the protective ensemble or base ensemble, or both, and hasbeen designed to allow for com
5、parisons of the ROM between ensembles of the same class (firefighterturnout gear) and from different classes (firefighter ensemble versus HAZMAT suit).1. Scope1.1 This practice specifies the test equipment and proce-dures for assessing ROM on subjects wearing a protectiveclothing ensemble.1.2 This p
6、ractice covers the ergonomic measurements ofrange of motion and subjective perceptions.1.3 To increase safety during testing, this practice requiresthe use of human participants who meet specific health andphysical fitness requirements.1.4 This practice does not attempt to determine otherclothing ch
7、aracteristics, such as thermal insulation and evapo-rative resistance of the protective clothing ensemble. TestMethods F1291 and F2370 can be used for these measure-ments.1.5 The values stated in this standard shall be SI units.1.6 It is the responsibility of the test laboratory to obtain thenecessa
8、ry and appropriate approval(s) required by their insti-tution for conducting tests using human participants.1.7 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety
9、and health practices and determine the applica-bility of regulatory limitations prior to use.1.8 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Stand
10、ards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2F1291 Test Method for Measuring the Thermal Insulation ofClothing Using a Heated ManikinF1494 Terminology Relating to Protective ClothingF237
11、0 Test Method for Measuring the Evaporative Resis-tance of Clothing Using a Sweating Manikin2.2 BSI Standards:3BS EN 469 Protective Clothing for Firefighters Perfor-mance Requirements for Protective Clothing for Firefight-ingBS 8469 Personal Protective Equipment for Firefighters Assessment of Ergono
12、mic Performance and Compatibility Requirements and Test Methods1This practice is under the jurisdiction of ASTM Committee F23 on PersonalProtective Clothing and Equipment and is the direct responsibility of SubcommitteeF23.60 on Human Factors.Current edition approved June 1, 2017. Published June 201
13、7. Originallyapproved in 2017. DOI: 10.1520/F3031-17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Availab
14、le from British Standards Institution (BSI), 389 Chiswick High Rd.,London W4 4AL, U.K., http:/.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized prin
15、ciples on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.12.3 ISO Standard:4ISO 10551 Ergonomics of the Thermal Environment Assessme
16、nt of the Influence of the Thermal EnvironmentUsing Subjective Judgement Scales3. Terminology3.1 Definitions:3.1.1 Refer to Terminology F1494 for definitions of termsused in this practice.3.1.2 clothing ensemble, nfor first responders, a protectiveensemble.4. Significance and Use4.1 This practice ca
17、n be used for the evaluation of the ROMof protective clothing ensembles worn under controlled condi-tions and can provide guidelines for the motion evaluation ofPPE.4.1.1 This practice utilizes a space large enough to allowusers to move freely during the tasks and a chair and a stretcherto measure c
18、ertain body joint mobility.NOTE 1Since required range of motion values will be related to thework task to be done while wearing the protective ensemble, the end usershould decide meaningfulness of the information provided by thisstandard for the performance of their job.4.2 This practice establishes
19、 general procedures for theevaluation based on the measurement of range of motion andsubjective perceptions.4.2.1 The data obtained can be used to evaluate the ROM ofthe test participant while wearing a protective clothing en-semble.4.2.2 The data are also potentially useful in the research anddevel
20、opment of advanced ensembles that are designed foroptimal mobility and comfort or reduce strain on the wearerthereby reducing the potential injury associated with wearingthe protective clothing ensemble.4.2.3 The data are also potentially useful for first responderorganizations to compare the ROM wh
21、ile wearing differentensembles.4.2.4 This practice could also be used by consensus stan-dards organizations in the development of ergonomic testcriteria for protective ensembles.4.3 Departures from the instructions in this practice have thepotential to lead to significantly different test results. T
22、echnicalknowledge concerning mobility of body joints, subjectiveevaluations, and testing practices is needed to evaluate whichdepartures from the instructions given in this practice aresignificant. All departures must be reported with the results.5. Apparatus5.1 Laboratory Space with Environmental M
23、easuresAroom that is large enough to accommodate the tasks that thetest participant will perform.Also, the room conditions shall bestable and recorded during testing. Use standard lab equipmentto measure the ambient environmental conditions under whichthe testing occurs.5.1.1 Relative Humidity Measu
24、rementUse a humidity-sensing device and have an accuracy of 65 % relative humid-ity and a repeatability of 63 % to be acceptable (for example,wet bulb/dry bulb, dew point hygrometer).5.1.2 Air Temperature SensorsUse shielded air tempera-ture sensors. The sensor shall have an overall accuracy of60.15
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF30312017STANDARDPRACTICEFORRANGEOFMOTIONEVALUATIONOFFIRSTRESPONDERX2019SPROTECTIVEENSEMBLES 评估 应急

链接地址:http://www.mydoc123.com/p-539925.html