ASTM F2732-2009 Standard Practice for Determining the Temperature Ratings for Cold Weather Protective Clothing《确定寒冷天气防护服温度额定值的标准实施规程》.pdf
《ASTM F2732-2009 Standard Practice for Determining the Temperature Ratings for Cold Weather Protective Clothing《确定寒冷天气防护服温度额定值的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2732-2009 Standard Practice for Determining the Temperature Ratings for Cold Weather Protective Clothing《确定寒冷天气防护服温度额定值的标准实施规程》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 2732 09Standard Practice forDetermining the Temperature Ratings for Cold WeatherProtective Clothing1This standard is issued under the fixed designation F 2732; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year
2、 of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONManufacturers of cold weather protective clothing want consumers to be thermally comfortablewhen wearing their pro
3、ducts. Therefore, they want to indicate the amount of warmth (that is,insulation) their products will provide to consumers at the point of sale. This is often expressed as atemperature rating on product labels and in product descriptions in catalogs. A temperature rating iscommonly understood to mea
4、n the lowest air temperature at which the average adult person will havean acceptable level of thermal comfort when wearing the product. Although it is not always stated onlabels or in catalogs, manufacturers are assuming that consumers will wear the appropriate amount ofclothing with the cold weath
5、er garments.Heated manikins can be used to measure the thermal resistance (insulation) and evaporativeresistance of clothing ensembles in accordance with F 1291 and F 2370, respectively. The thermalinsulation value of a cold weather protective ensemble can be used in heat loss models to estimate the
6、thermal comfort of people in cold environments. This approach has already been used for sleepingbags (see EN 13537).1. Scope1.1 This standard practice covers the determination of thetemperature rating of cold weather protective clothing en-sembles. It involves measuring the insulation value of aclot
7、hing ensemble with a heated manikin in accordance withF 1291 and using a heat loss model to predict the lowestenvironmental temperature for comfort.1.2 The predictive model used in this standard estimates theevaporative heat loss from a person wearing cold weatherclothing as opposed to measuring the
8、 evaporative resistance ona sweating manikin. If a person is active and gets overheated ina cold environment, he/she can adjust the garments in order todissipate excess heat.1.3 The temperature ratings estimated by this standardpractice are guidelines for thermal comfort that are designed toprotect
9、people from hypothermia when wearing cold weatherprotective garments. However, localized cooling, discomfort,and even frostbite could still occur at extremely low tempera-tures because clothing insulation is not evenly distributed overthe body surface. In addition, some body parts (for example,ears,
10、 fingers, toes) have a high surface area relative to theirmass, and consequently lose heat at a faster rate than otherparts of the body.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to es
11、tablish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2F 1291 Test Method for Measuring the Thermal Insulationof Clothing Using a Heated ManikinF 2370 Test Method for Measuring the Evaporativ
12、e Resis-tance of Clothing Using a Sweating Manikin2.2 Other Standards:3EN 13537 Requirements for Sleeping BagsANSI/ASHRAE 55-2004 Thermal Environmental Condi-tions for Human Occupancy1This practice is under the jurisdiction of ASTM Committee F23 on PersonalProtective Clothing and Equipment and is th
13、e direct responsibility of SubcommitteeF23.60 on Human Factors.Current edition approved May 15, 2009. Published June 2009.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, ref
14、er to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United Stat
15、es.3. Terminology3.1 Definitions:3.1.1 clo, na unit of thermal resistance (insulation) equalto 0.155 K-m2/W.3.1.1.1 DiscussionThe value of the clo was selected asroughly the insulation value of typical indoor clothing, whichshould keep a resting man (producing heat at the rate of 58W/m2) comfortable
16、 in an environment at 21C, air movement0.1 m/s.3.1.2 clothing ensemble, na group of garments worntogether on the body at the same time.3.1.3 temperature rating, nthe lowest environmental tem-perature at which a person can remain thermally neutral whilewearing a particular clothing ensemble.3.1.4 the
17、rmal comfort, nthat condition of mind whichexpresses satisfaction with the thermal environment and isassessed by subjective evaluation (see ANSI/ASHRAE 55-2004).3.1.5 thermal insulation, nthe resistance to dry heattransfer by way of conduction, convection, and radiation.3.1.5.1 Discussionthe followi
18、ng insulation values can bedetermined with a thermal manikin using clo units:Ia= thermal resistance (insulation) of the air layer on thesurface of the nude manikin.It= total thermal resistance (insulation) of the clothingand surface air layer around the manikin.Icl= intrinsic thermal resistance (ins
19、ulation) of the cloth-ing.Total insulation values are measured directly with a manikin.Intrinsic clothing insulation values are determined by subtract-ing the air layer resistance around the clothed manikin from thetotal insulation value for the ensemble.4. Significance and Use4.1 This practice can
20、be used to measure the insulationprovided by different cold weather clothing systems using aheated manikin (see F 1291) and to predict the temperaturerating for comfort using whole body heat loss models.4.1.1 The temperature rating is for an ensemblenot anindividual garment. However, manufacturers w
21、ant to label coldweather garments with a temperature rating to help consumersselect the product that will best meet their needs. Therefore, thestandard is limited to garments that cover a substantial amountof body surface area such as jackets, coats, and insulated pants,coveralls, or snow suits. The
22、 temperature ratings of head wear,footwear, and hand wear cannot be determined with thispractice.4.1.2 The temperature predictions determined by this stan-dard practice are for adults only. The physiology of children issignificantly different from that of adults, so a modified heatloss model would n
23、eed to be used to predict the comfort ofchildren wearing outdoor clothing.4.1.3 The temperature ratings determined by this standardpractice and listed on garment labels are only guidelines forcomfort and will be affected by the garments consumers wearwith them, their activity level during wear, and
24、individualdifferences in the physiological characteristics of people (forexample, gender, age, body mass, etc.).5. Calibration of Manikin5.1 ManikinUse a thermal manikin as described inF 1291.5.2 CalibrationCalibrate the manikin using the proce-dures in F 1291.5.2.1 The intrinsic clothing insulation
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF27322009STANDARDPRACTICEFORDETERMININGTHETEMPERATURERATINGSFORCOLDWEATHERPROTECTIVECLOTHING 确定 寒冷

链接地址:http://www.mydoc123.com/p-539355.html