1、Designation: F 433 02Standard Practice forEvaluating Thermal Conductivity of Gasket Materials1This standard is issued under the fixed designation F 433; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A n
2、umber in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers a means of measuring the amountof heat transfer quantitatively through a material or system.1.2 This practice is s
3、imilar to the Heat Flow Meter Systemof Method C 518, but modified to accommodate small testsamples of higher thermal conductance.1.3 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.4 This standard does not purport to address
4、all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:C 518 Test Method f
5、or Steady-State Thermal TransmissionProperties by Means of the Heat Flow Meter Apparatus2D 2214 Test Method for Estimating the Thermal Conduc-tivity of Leather with the Cenco-Fitch Apparatus3F 104 Classification System for Nonmetallic Gasket Mate-rials43. Terminology3.1 Definitions:3.1.1 thermal con
6、ductivity, k, of a solid materialthe timerate of steady heat flow, watts (or Btu/h), through a unit area,m2(or ft2), per unit temperature gradient in the directionperpendicular to an isothermal surface C/m (or F/in.). Thek-factor is expressed W/mK (Btuin./hft2F).3.2 Symbols:k = thermal conductivity,
7、 W/mK (Btuin./hft2F)C = thermal conductance, W/m2K (Btu/hft2F)Dx = sample thickness, mm (in.)A = sample cross-sectional area, m2(ft2)q = heat flow, W (Btu/h)f = heat flow transducer output, mVN = heat flow transducer calibration constant,W/m2mV (Btu/hft2mV)Nf = heat flux, W/m2(Btu/hft2)DT = temperat
8、ure difference, C (F) or mVT1= temperature of lower sample surface,C (F)or mVT2= temperature of upper sample surface, C (F)or mVTh= temperature of HFT surface facing sample, C(F) or mVTc= temperature of upper heater surface facingsample, C (F) or mVT = temperature, C (F)d = total temperature drop ac
9、ross interfaces be-tween sample and adjacent surfaces, C (F)or mVr = coefficient of thermal resistance at interfaces,m2K/W (hft2F/Btu)a = correction constantsubscript s = unknown samplesubscript r = known calibration sample4. Summary of Practice4.1 The sample and the heat flow transducer (HFT) aresa
10、ndwiched between two controlled heater plates. The lowerheater is set at a higher temperature than the upper plate toproduce a flow of heat through the sample. The differential ofthese two temperatures, DT, sensed by thermocouples, isamplified along with the electrical output, f, of the HFT and isdi
11、rectly proportional to the heat flow through the sample,expressed as W/m2(Btu/hft2). See Appendix for furtherinformation. This recommended practice can be used formeasuring heat transfer at a hot side temperature up to 200C(392F). See Figs. 1-5.5. Significance and Use5.1 This practice is designed to
12、 compare related materialsunder controlled conditions and their ability to maintain aminimum amount of thermal conductance. Test results shouldbe correlated with field results in order to predict heat transferproperties in particular applications.1This practice is under the jurisdiction of ASTM Comm
13、ittee F03 on Gaskets andis the direct responsibility of Subcommittee F03.10 on Composite Gaskets.Current edition approved October 10, 2002. Published October 2002.2Annual Book of ASTM Standards, Vol 04.06.3Annual Book of ASTM Standards, Vol 15.04.4Annual Book of ASTM Standards, Vol 09.02.1Copyright
14、ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.2 This practice may be used as a routine test when agreedupon by the user and the producer.6. Apparatus6.1 Heat Flow Transducer (HFT), with controlled heaterplates, thermocouples, and an analog
15、computer module.57. Test Specimen7.1 The sample size shall be a 50.8-mm (2-in.) diameterdisk 60.25 mm (60.010 in.) from 2.29 to 12.7 mm (0.090 to0.500 in.) thick.8. Conditioning8.1 Condition the cut specimens in accordance with theirclassification, as required in Classification F 104.9. Procedure9.1
16、 Test temperatures are suggested from 100 to 175C (212to 347F) or whatever is agreed upon between the producer anduser. (The guard heater is usually set at or near the averagesample temperature between the lower and upper heaterplates.)9.1.1 Release the compressive load, pull out the tray, andload t
17、he sample. Care must be maintained to ensure that thetray compartment is free of any foreign matter. Clean asrequired.9.1.2 Push the tray back into the chamber with a ball andplunger locking the tray into position.9.1.3 Close the test section door and switch the air control to“stack clamped.” The sa
18、mple holder is now raised automati-cally until the sample is clamped in place between the upperand lower heaters. The compressive load can be adjusted bycontrolling the air pressure at the rear of the unit. A pressure of0.345 MPa (50 psi) is the recommended maximum and shouldbe specified by both the
19、 producer and user to ensure repeatableresults.9.1.4 Allow from 1 to 2 h for the reading to stabilize. Readthe sample thermal conductance and temperature directly fromdigital meters on the front panel. The instrument has stabilizedwhen the temperature indicated changes by no more than65 %/h and the
20、conductance indicated changes no more than62 %/h.10. Report10.1 The report shall include the following:10.1.1 Sample conditioning procedure,10.1.2 Ambient temperature,10.1.3 Sample hot side temperature, Th,10.1.4 Sample cold side temperature, Tc,10.1.5 Sample temperature drop, ThTc,10.1.6 Average sa
21、mple temperature, (Th+ Tc)/2,10.1.7 Sample thickness, Dx,10.1.8 Thermal conductivity, k, and10.1.9 Compressive load.5The sole source of supply of the apparatus known to the committee at this timeis Holometrix, Inc., 25 Wiggins Avenue, Bedford, MA 017302323. If you areaware of alternative suppliers,
22、please provide this information to ASTM Headquar-ters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend.FIG. 1 Heat Flow Meter Assembly With Water-Cooled Heat SinkFIG. 2 HFT Electrical Output and Heat Flow Section WithTemperatu
23、re SensorsF43302211. Precision and Bias11.1 The precision of the practice is expected to be within65%.12. Keywords12.1 comparative thermal conductance; heat flow; thermalconductanceFIG. 3 Location of Thermocouples to Produce a Temperature Gradient Through the Test SampleFIG. 4 The Hot and Cold Sampl
24、e Surface Temperature Differential Amplified with the HFT Output, Divided Electronically, and DisplayedDigitallyFIG. 5 Clarification of Fig. 4 Showing the Calibration to Obtain the Correction Constant Correct Value Before Testing an UnknownSampleF433023APPENDIXES(Nonmandatory Information)X1. GENERAL
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF4332002STANDARDPRACTICEFOREVALUATINGTHERMALCONDUCTIVITYOFGASKETMATERIALS 衬垫 材料 导热性 评定 标准 实施 规程 PDF

链接地址:http://www.mydoc123.com/p-536638.html