ASTM F1837M-1997(2007) Standard Specification for Heat-Shrink Cable Entry Seals (Metric)《热缩电缆引入密封的标准规范(公制)》.pdf
《ASTM F1837M-1997(2007) Standard Specification for Heat-Shrink Cable Entry Seals (Metric)《热缩电缆引入密封的标准规范(公制)》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1837M-1997(2007) Standard Specification for Heat-Shrink Cable Entry Seals (Metric)《热缩电缆引入密封的标准规范(公制)》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 1837M 97 (Reapproved 2007)An American National StandardStandard Specification forHeat-Shrink Cable Entry Seals (Metric)1This standard is issued under the fixed designation F 1837M; the number immediately following the designation indicates the year oforiginal adoption or, in the case
2、of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers the general requirements forheat-shrink cable entry seals. Cable e
3、ntry seals are intended formaking electrical cable penetrations into connection boxes,bulkheads, or other enclosures. These devices are suitable forboth thin wall enclosures up to 5 mm (316 in.) thick andthick-wall enclosures of 5 mm to 19 mm (316 in. to34 in.) thick.1.2 Cable entry seals shall have
4、 factory-applied adhesivethat provides the seal to wire and cable jackets.1.3 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its
5、use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to its use.2. Referenced Documents2.1 ASTM Standards:2D 149 Test Method for Dielectric Breakdown Voltage andDielectric Stre
6、ngth of Solid Electrical Insulating Materialsat Commercial Power FrequenciesD 257 Test Methods for DC Resistance or Conductance ofInsulating MaterialsD 412 Test Methods for Vulcanized Rubber and Thermo-plastic ElastomersTensionD 570 Test Method for Water Absorption of PlasticsD 635 Test Method for R
7、ate of Burning and/or Extent andTime of Burning of Plastics in a Horizontal PositionD 747 Test Method for Apparent Bending Modulus ofPlastics by Means of a Cantilever BeamD 792 Test Methods for Density and Specific Gravity (Rela-tive Density) of Plastics by DisplacementD 2240 Test Method for Rubber
8、PropertyDurometerHardnessD 2671 Test Methods for Heat-Shrinkable Tubing for Elec-trical UseD 2863 Test Method for Measuring the Minimum OxygenConcentration to Support Candle-Like Combustion ofPlastics (Oxygen Index)D 3149 Specification for Crosslinked Polyolefin Heat-Shrinkable Tubing for Electrical
9、 InsulationD 4572 Test Method for Rubber ChemicalsWet SieveAnalysis of SulfurD 4732 Specification for Cool-Application Filling Com-pounds for Telecommunications Wire and Cable2.2 ASME StandardASME B1.1 Unified Inch Screw Threads (UN and UNRThread Form)32.3 NEMA Standards:4NEMA 250 Enclosures for Ele
10、ctrical Equipment (1000Volts Max)2.4 IEC Standard:IEC 68-2-6 Environmental TestingPart 2: TestsTest FC:Vibration (Sinusoidal) Sixth Edition53. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 heat-shrink cable entry seal, nheat-shrinkable tubemaking a watertight, fume-tight seal w
11、here cable connectionsboxes, bulkheads, or other enclosures.3.1.2 polyolefin, na polymer made by the polymerizationof hydrocarbon olefins or copolymerization olefins.4. Classification4.1 Heat-shrink cable entry seals shall be of the followingtypes:4.1.1 Type 1, standard cable entry seals for thin-wa
12、ll enclo-sures shall consist of the three part assembly; a rigid plasticnut, O-ring, and heat-shrinkable molded area.4.1.1.1 Type I1, molded area configured with one openingfor a single wire or cable entry.1This specification is under the jurisdiction of ASTM Committee F25 on Shipsand Marine Technol
13、ogy and is the direct responsibility of Subcommittee F25.10 onElectrical.Current edition approved May 1, 2007. Published June 2007. Originallyapproved in 1997. Last previous edition approved in 2002 as F 1837M - 97(2002).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact
14、 ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American Society of Mechanical Engineers (ASME), ASMEInternational Headquarters, Three Park Ave., New York, NY 10016-5990, h
15、ttp:/www.asme.org.4Available from National Electrical Manufacturers Association (NEMA), 1300N. 17th St., Suite 1752, Rosslyn, VA 22209, http:/www.nema.org.5Available from International Electrotechnical Commission (IEC), 3, rue deVarembe, Case Postale 131, CH-1211, Geneva 20, Switzerland.1Copyright A
16、STM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.1.1.2 Type I2, molded area configured with two equalsize openings to seal two wires or cables.4.1.1.3 Type I3, molded area configured with three equalsize openings to seal three wires or cables.4
17、.1.1.4 Type I4, molded area configured with four equalsize openings to seal four wires or cables.4.1.1.5 Type I5, molded area configured with six equal sizeopenings to seal six wires or cables.4.1.1.6 Type I6, molded area configured with eight equalsize openings to seal eight wires or cables.4.1.2 T
18、ype II, cable entry seal for threaded hole applicationsshall consist of a one-part assembly that combines a taperednational pipe thread (NPT) in rigid plastic with heat-shrinkablemolded area.4.1.2.1 Type II1, molded area configured with one openingfor a single wire or cable entry.4.1.2.2 Type II2, m
19、olded area configured with two equalsize openings to seal two wires or cables.4.1.2.3 Type II3, molded area configured with three equalsize openings to seal three wires or cables.4.1.2.4 Type II4, molded area configured with four equalsize openings to seal four wires or cables.4.1.3 Type III, right
20、angle cable entry seal for thin-wallenclosure shall consist of a three part assembly; a rigid plasticnut, O-ring, and heat-shrinkable molded area.4.1.4 Type IV, right angle cable entry seal for threaded holeapplication shall consist of a one-part assembly that combinesa tapered national pipe thread
21、(NPT) in rigid plastic with aheat-shrinkable molded area.5. Ordering Information5.1 Orders for cable entry seals under this specification shallinclude the following:5.1.1 Part Number (see Figs. 1-6).5.1.2 Quantity (per each part).6. Materials and Manufacture6.1 The rigid plastic parts shall be made
22、from polyamide(nylon), (or polyester material, or both.) The material shall beGroup 1, Class 8, Grade 1 as specified in Specification D 4066.6.1.1 Threads shall be unified form UN 2A or 2B or taperpipe thread (NPT) as specified in ASME B1. 1.6.2 The heat-shrinkable tubing shall be of a crosslinkedpo
23、lyolefin in accordance with Type III of Specification D 3149.6.3 The adhesive shall be general purpose high-bond-strength adhesive sealant that provides stain relief and envi-ronmental sealing of heat-shrink tubing to cable jackets.6.4 O-rings shall be made of a material conforming to TypeII of Spec
24、ification D 4732.6.5 The polyolefin heat-shrinkable tubing shall met require-ments of Test Methods D 2671.7. Other Requirements7.1 Dimensional RequirementsCable-entry seals shallconform to the dimensional requirements of Tables 1-6. Type Icable-entry seals are presented in Fig. 1 and Fig. 2. Type II
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF1837M19972007STANDARDSPECIFICATIONFORHEATSHRINKCABLEENTRYSEALSMETRIC 电缆 引入 密封 标准规范 公制 PDF

链接地址:http://www.mydoc123.com/p-535801.html