1、Designation: E790 15Standard Test Method forResidual Moisture in Refuse-Derived Fuel AnalysisSamples1This standard is issued under the fixed designation E790; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisio
2、n. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the measurement of residualmoisture in refuse-derived fuel (RDF) analysis samples. It isused to calculate
3、on a dry basis other determinations performedon analysis RDF samples. It is used with air-dry moistureresults to calculate total moisture (Note 1). The total moistureis used to calculate as-received values or other analysesperformed on a sample.NOTE 1In some instances RDF moisture may change during
4、size-reduction steps of the RDF analysis sample preparation procedure. Thismoisture change, unless suitable corrections are made, will affect theaccuracy of the total moisture value as calculated from the air-dry andresidual moisture results.1.2 The values stated in SI units are to be regarded assta
5、ndard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the app
6、lica-bility of regulatory limitations prior to use. For more specificprecautionary information see Section 7.2. Referenced Documents2.1 ASTM Standards:2D3173 Test Method for Moisture in the Analysis Sample ofCoal and CokeD5681 Terminology for Waste and Waste ManagementE180 Practice for Determining t
7、he Precision of ASTMMethods for Analysis and Testing of Industrial and Spe-cialty Chemicals (Withdrawn 2009)33. Terminology3.1 For definitions of terms used in this test method, refer toTerminology D5681.4. Summary of Test Method4.1 This test method is based on the weight loss of anair-dried analysi
8、s RDF sample under rigidly controlled condi-tions of temperature, time, and air flow.4.2 The total moisture is calculated from the loss or gainupon sample air drying and the residual moisture as determinedby this test method.5. Significance and Use5.1 The procedure in this test method for a sample a
9、sspecified herein is intended for the purpose of determining theresidual moisture present in a RDF analysis sample.5.2 The residual moisture value is used to correct as-determined analysis results such as gross heating value, sulfur,and ash to dry sample basis results.6. Apparatus6.1 Drying Oven:6.1
10、.1 Referee TypeThe oven shall be constructed to have auniform temperature within the specimen chamber, have aminimum excess air volume, and be capable of constanttemperature regulation at 107 6 3C. Provision shall be madefor renewing the preheated air in the oven at the rate of two tofour times the
11、oven air volume a minute, with the intake airdried by passing through a desiccant. An oven similar to theone illustrated in Fig. 1 of Test Method D3173 is suitable.6.1.2 Routine TypeA drying oven of either the mechanicalor natural circulation type which is capable of constant uniformtemperature with
12、in the specimen chamber regulated at 107 63C.NOTE 2Either type of oven may be used for routine determinations.However, the referee-type oven shall be used to resolve differencesbetween determinations.6.2 ContainersSample ash determinations are made usinga porcelain capsule 22 mm in depth and 44 mm i
13、n diameter ora fused silica capsule of similar shape. A well-fitting flataluminum cover is used when ashing samples. Platinum1This test method is under the jurisdiction of ASTM Committee D34 on WasteManagement and is the direct responsibility of Subcommittee D34.03 on Treatment,Recovery and Reuse.Cu
14、rrent edition approved Sept. 1, 2015. Published September 2015. Originallyapproved in 1981. Last previous edition approved in 2008 as E790 08. DOI:10.1520/E0790-15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Boo
15、k of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
16、1crucibles or glass capsules with ground-glass caps may also beused. They should be as shallow as possible while remainingconvenient to handle.6.3 Analytical BalanceBalance capable of weighing withan accuracy of 0.1 mg.6.4 Analysis Sample ContainersHeavy (minimum 4 mil),vapor-impervious bags, proper
17、ly sealed; or noncorroding cans,glass jars, or plastic bottles with air-tight sealing covers to storeRDF samples for analysis. Containers shall be checked forsuitability by measuring weight loss or gain of the sample andcontainer stored for 1 week under ambient laboratory condi-tions. The weight los
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME79020154634STANDARDTESTMETHODFORRESIDUALMOISTUREINREFUSEDERIVEDFUELANALYSISSAMPLES 回收 燃料 分析 样品 残留

链接地址:http://www.mydoc123.com/p-533529.html