ASTM E790-1987(2004) Standard Test Method for Residual Moisture in a Refuse-Derived Fuel Analysis Sample《回收废燃料分析样品中残留潮气的测试方法》.pdf
《ASTM E790-1987(2004) Standard Test Method for Residual Moisture in a Refuse-Derived Fuel Analysis Sample《回收废燃料分析样品中残留潮气的测试方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E790-1987(2004) Standard Test Method for Residual Moisture in a Refuse-Derived Fuel Analysis Sample《回收废燃料分析样品中残留潮气的测试方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 790 87 (Reapproved 2004)Standard Test Method forResidual Moisture in a Refuse-Derived Fuel AnalysisSample1This standard is issued under the fixed designation E 790; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、 year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the measurement of the residualmoisture in an analysis sample of RDF. It is used to
3、calculateto the dry basis other determinations performed on the analysissample. It is used with the air-dry moisture results to calculatetotal moisture (Note 1). The total moisture is used to calculateas-received values or other analyses performed on the sample.NOTE 1In some instances RDF moisture m
4、ay change during thesize-reduction steps of the analysis sample preparation procedure. Thismoisture change, unless suitable corrections are made, will affect theaccuracy of the total moisture value as calculated from the air-dry andresidual moisture results.1.2 The values stated in acceptable metric
5、 units are to beregarded as standard. The values given in parentheses are forinformation only.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health pra
6、ctices and determine the applica-bility of regulatory limitations prior to use. For more specificprecautionary information see Section 7.2. Referenced Documents2.1 ASTM Standards:2D 3173 Test Method for Moisture in theAnalysis Sample ofCoal and CokeE 180 Practice for Developing Precision of ASTM Met
7、hodsfor Analysis and Testing of Industrial Chemicals3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 air dryinga process of partial drying of RDF tobring its moisture content near to equilibrium with the atmo-sphere in which further reduction, division, and characteriza-tion of
8、 the sample are to take place. In order to bring about theequilibrium, the RDF is usually subjected to drying undercontrolled temperature conditions ranging from 30 to 40C.3.1.2 analysis samplethe final subsample prepared fromthe air-dried laboratory sample but reduced by passing througha mill with
9、a 0.5-mm (0.02-in.) size or smaller final screen.3.1.3 biasa systematic error that is consistently negativeor consistently positive. The mean of errors resulting from aseries of observations that does not tend towards zero.3.1.4 gross samplea sample representing one lot andcomposed of a number of in
10、crements on which neither reduc-tion nor division has been performed.3.1.5 laboratory samplea representative portion of thegross sample received by the laboratory for analysis.3.1.6 lota large designated quantity (greater than thequantity of the final sample) of RDF which can be representedby a prop
11、erly selected gross sample.3.1.7 precisiona term used to indicate the capability of aperson, an instrument, or a method to obtain reproducibleresults; specifically, a measure of the random error as ex-pressed by the variance, the standard error, or a multiple of thestandard error.3.1.8 refuse-derive
12、d fuelssolid forms of refuse-derivedfuels from which appropriate analytical samples may beprepared are defined as follows in ASTM STP 832.3RDF-1Wastes used as a fuel in as-discarded form withonly bulky wastes removed.RDF-2Wastes processed to coarse particle size with orwithout ferrous metal separati
13、on.RDF-3Combustible waste fraction processed to particlesizes, 95 % passing 2-in. square screening.RDF-4Combustible waste fraction processed into powderform, 95 % passing 10-mesh screening.RDF-5Combustible waste fraction densified (compressed)into the form of pellets, slugs, cubettes, or briquettes.
14、3.1.9 representative samplea sample collected in such amanner that it has characteristics equivalent to the lot sample.1This test method is under the jurisdiction of ASTM Committee D34 on WasteManagement and is the direct responsibility of Subcommittee D34.03.02 onMunicipal Recovery and Reuse.Curren
15、t edition approved Aug. 28, 1987. Published October 1987. Orginallypublished as E 790 81. Last previous edition E 790 81.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refe
16、r to the standards Document Summary page onthe ASTM website.3Thesaurus on Resource Recovery Terminology, ASTM STP 832, ASTM, 1983,p. 72.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.1.10 sample divisionthe process of extracting a
17、 smallersample from a sample so that the representative properties ofthe larger sample are retained. During this process it is assumedthat no change in particle size or other characteristics occurs.3.1.11 sample preparationthe process that includes dry-ing, size reduction, division, and mixing of a
18、laboratory samplefor the purpose of obtaining an unbiased analysis sample.3.1.12 sample reductionthe process whereby sample par-ticle size is reduced without change in sample weight.3.1.13 significant lossany loss that introduces a bias infinal results that is of appreciable importance to concernedp
19、arties.4. Summary of Test Method4.1 This test method is based on the loss in weight of anair-dried analysis sample of RDF under rigidly controlledconditions of temperature, time, and air flow.4.2 The total moisture is calculated from the loss or gain inair drying and the residual moisture as determi
20、ned by this testmethod.5. Significance and Use5.1 The treatment of the sample as specified herein isintended for the purpose of determining the residual moisturepresent in an analysis sample of RDF.5.2 The residual moisture value is used to convert as-determined analyses such as gross heating value,
21、 sulfur, andash to a dry sample basis.6. Apparatus6.1 Drying Oven:6.1.1 Referee TypeThe oven shall be so constructed as tohave a uniform temperature within the specimen chamber, havea minimum excess air volume, and be capable of constanttemperature regulation at 107 6 3C. Provision shall be madefor
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME79019872004STANDARDTESTMETHODFORRESIDUALMOISTUREINAREFUSEDERIVEDFUELANALYSISSAMPLE 回收 燃料 分析 样品 残留

链接地址:http://www.mydoc123.com/p-533527.html