ASTM F219-1996(2009) Standard Test Methods of Testing Fine Round and Flat Wire for Electron Devices and Lamps《电子器件和电灯用细圆丝和扁线的标准试验方法》.pdf
《ASTM F219-1996(2009) Standard Test Methods of Testing Fine Round and Flat Wire for Electron Devices and Lamps《电子器件和电灯用细圆丝和扁线的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F219-1996(2009) Standard Test Methods of Testing Fine Round and Flat Wire for Electron Devices and Lamps《电子器件和电灯用细圆丝和扁线的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 219 96 (Reapproved 2009)Standard Test Methods of TestingFine Round and Flat Wire for Electron Devices and Lamps1This standard is issued under the fixed designation F 219; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisio
2、n, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover the testing of fine wire, flat orround, approximately 0.010 in. (0.25 mm) and
3、smaller indiameter or thickness, used in electronic devices and lamps.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.3 This standa
4、rd does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of whoever uses this standard to consult andestablish appropriate safety and health practices and deter-mine the applicability of regulatory limitations prior to use.2. Referenced Docum
5、ents2.1 ASTM Standards:2B63 Test Method for Resistivity of Metallically Conduct-ing Resistance and Contact MaterialsD 374 Test Methods for Thickness of Solid Electrical Insu-lationF16 Test Methods for Measuring Diameter or Thickness ofWire and Ribbon for Electronic Devices and LampsF 205 Test Method
6、 for Measuring Diameter of Fine Wire byWeighingF 289 Specification for Molybdenum Wire and Rod forElectronic Applications3. Test Specimens3.1 The number of spools per shipment to be checked shallbe agreed upon by the producer and consumer. Three testspecimens from each spool to be tested shall be ta
7、ken for thepurpose of each of the tests covered by these methods, exceptSection 4, where one specimen per shipment shall be submit-ted. These specimens shall be selected sufficiently far fromeither end of the spool of wire to be free from kinks, bends, anddistortion. With the exceptions mentioned in
8、 3.2, the specimensshall be taken from points in the length of the wire separated byat least 1 ft (305 mm).3.2 For the edgewise curvature test, straightness test, andtension tests the specimens shall be taken from points in thelength of the wire separated by at least 3 ft (0.9 m).4. Chemical Analysi
9、s4.1 In case of disagreement between producer and consumerchemical analysis of the material shall be made in accordancewith the methods of the American Society for Testing andMaterials for the respective materials when such methods ofanalysis are available. When ASTM test methods are notavailable, t
10、he analytical procedures shall be agreed upon by theproducer and the consumer.5. Dimensions5.1 Procedure A for Round WireDetermine the weight-size of round wire in accordance with Test Method F 205.5.2 Procedure B for Round WireAs an alternative method,the diameter of wire over 0.005 in. (0.13 mm) m
11、ay bedetermined in accordance with Test Methods D 374.5.3 Procedure for Flat Wire:5.3.1 Determine the dimensions of flat wire in accordancewith 5.1 in conjunction with width as measured in accordancewith 5.2, or if agreed upon by the manufacturer and thepurchaser, any dimension exceeding 0.005 in. m
12、ay be deter-mined in accordance with 5.2 alone.5.3.2 In determining the width of flat wire, form a flatwiseloop loosely with the ends held between the fingers. The minoraxis of the loop shall be12 to34 of the diameter of themicrometer jaws. Measure the width of the ribbon with thecurve loop perpendi
13、cular to the micrometer jaws. Take care notto distort the ribbon or bend it out of the correct plane duringmeasurement.5.4 In case of disagreement between producer and con-sumer, Test Methods F16shall be used as the referee method.1These test methods are under the jurisdiction of ASTM Committee F01
14、onElectronics and are the direct responsibility of Subcommittee F01.03 on MetallicMaterials.Current edition approved May 1, 2009. Published July 2009. Originally approvedin 1947. Last previous edition approved in 2002 as F 219 96 (2002).2For referenced ASTM standards, visit the ASTM website, www.ast
15、m.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.5 Repor
16、tThe report shall include the average weight ofwire or ribbon in mg/200 mm to three significant figures. Theaverage measurements for diameter, width, or thickness shallbe reported to the nearest 0.0001 in. (0.002 mm).6. Out-of-Roundness6.1 ProcedureMeasure out-of-roundness on round wireover 0.005 in
17、. (0.13 mm) in diameter in accordance withSections 3 and 4 of Test Methods D 374. For wire 0.005 in. orless in diameter the same method shall apply except a benchtype micrometer reading to 0.0001 in. (0.002 mm) shall beused. Make the measurements by exploring a plane of crosssection of the test spec
18、imen to determine both minimum andmaximum values of diameter at the cross section. Take care tohave the specimen straight so that its normal curvature will notinfluence readings.6.2 CalculationCalculate out-of-roundness as follows:Out2of2roundness, percent 5 A 2 B!/A 3 100where:A = maximum diameter
19、of the cross section, in. (or mm),andB = minimum diameter of the cross section, in. (or mm).6.3 ReportThe report shall include the average of thethree determinations of out-of-roundness reported to the near-est 1 percent.7. Edgewise Curvature of Ribbon7.1 ProcedureLay a specimen 200 mm in length on
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF21919962009STANDARDTESTMETHODSOFTESTINGFINEROUNDANDFLATWIREFORELECTRONDEVICESANDLAMPS 电子器件 电灯 用细圆丝

链接地址:http://www.mydoc123.com/p-532510.html