1、Designation: E2539 14Standard Test Method forMultiangle Color Measurement of Interference Pigments1This standard is issued under the fixed designation E2539; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision
2、. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONObjects that exhibit a change in color with different angles of illumination and view are said to be“gonioapparent.” The tristimulu
3、s colorimetric values of gonioapparent objects are derived using thespectral reflectance factors obtained from spectrometric measurements or colorimetric measurementsat various angles of illumination and detection.The tristimulus colorimetric values are computed usingthe spectral reflectance factors
4、 of the object, the CIE Standard Observer, and the spectral powerdistribution of the illuminant, as described in Practice E308. This Test Method, E2539, specifies thecolor measurement of interference pigments at various illumination and detection angles.1. Scope1.1 This test method covers the instru
5、mental requirementsand required parameters needed to make instrumental colormeasurements of thin film interference pigments. This testmethod is designed to encompass interference pigments used inarchitectural applications, automobiles, coatings, cosmetics,inks, packaging, paints, plastics, printing,
6、 security, and otherapplications.1.2 Characterization of the optical behavior of materialscolored with interference pigments requires measurement atmultiple angles of illumination and detection.1.3 Data taken utilizing this test method are quantitative andare appropriate for quality control of inter
7、ference pigmentcolor.1.4 The measurement results are usually expressed as re-flectance factors, tristimulus color values, or as CIE L*a*b*color coordinates and color difference.1.5 The totality of data taken may not be necessary forevaluating mixtures also containing non-interference pigments.The co
8、mmittee is investigating and evaluating the appropriate-ness of this test method for those materials. It is the responsi-bility of the users to determine the applicability of this testmethod for their specific applications.1.6 Interference pigments are typically evaluated for colorand color appearan
9、ce in a medium, such as paint or ink. Thegonioapparent effect depends strongly on the physical andchemical properties of the medium. Some of the propertiesaffecting color and color appearance include vehicle viscosity,thickness, transparency, and volume solids. As a general rule,for quality control
10、purposes, interference pigments are bestevaluated in a masstone product form. In some cases thisproduct form may be the final product form, or more typicallya qualified simulation of the intended product form (such as apaint drawdown) that in terms of color and appearancecorrelates to final product
11、application.1.7 This standard does not address the requirements forcharacterizing materials containing metal flake pigments. Mea-surements of the optical characteristics of materials containingmetal flake pigments are described in Test Method E2194.1.8 The values stated in SI units are to be regarde
12、d as thestandard. The values given in parentheses are for informationonly.1.9 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine
13、 the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E284 Terminology of AppearanceE308 Practice for Computing the Colors of Objects by Usingthe CIE SystemE805 Practice for Identification of Instrumental Methods of1This test method is under the jurisd
14、iction of ASTM Committee E12 on Colorand Appearance and is the direct responsibility of Subcommittee E12.12 onGonioapparent Color.Current edition approved Nov. 1, 2014. Published November 2014. Originallyapproved in 2008. Last previous edition approved in 2012 as E2539 12. DOI:10.1520/E2539-14.2For
15、referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700,
16、West Conshohocken, PA 19428-2959. United States1Color or Color-Difference Measurement of MaterialsE1164 Practice for Obtaining Spectrometric Data for Object-Color EvaluationE1345 Practice for Reducing the Effect of Variability ofColor Measurement by Use of Multiple MeasurementsE1708 Practice for Ele
17、ctronic Interchange of Color andAppearance DataE1767 Practice for Specifying the Geometries of Observa-tion and Measurement to Characterize the Appearance ofMaterialsE2194 Test Method for Multiangle Color Measurement ofMetal Flake Pigmented MaterialsE2480 Practice for Conducting an Interlaboratory S
18、tudy toDetermine the Precision of a Test Method with Multi-Valued Measurands2.2 ISCC Publications:3Technical Report 20031 Guide to Material Standards andTheir Use in Color Measurement3. Terminology3.1 Terms and definitions in Terminology E284, and Prac-tice E1767 and Test Method E2194 are applicable
19、 to this testmethod. See Section 5 of E284 for “Specialized Terminologyon Gonioapparent Phenomena.”4. Summary of Test Method4.1 This test method describes the instrumental geometries,including abridged goniospectrometry, used to measure inter-ference pigments. Optical characterization requires color
20、 mea-surement at multiple illumination and multiple detection anglesspecified in this procedure. These sets of illumination anddetection angles are specified in the test method. Standardiza-tion and verification of the instrument used to measure thesematerials are defined. The requirements for selec
21、tion of speci-mens and measurement procedures are provided. The resultsare reported in terms of reflectance factors, CIE tristimulusvalues, and other color coordinate systems that define the colorof the object. Expected values of precision are presented.5. Significance and Use5.1 This test method is
22、 designed to provide color dataobtained from spectral reflectance factors at specific illumina-tion and detection angles for interference pigments. Informa-tion presented in this test method is based upon data taken onmaterials exclusively pigmented with interference pigments.5.2 These data can be u
23、sed for acceptance testing, designpurposes, research, manufacturing control, and quality control.5.3 Specimens must be statistically representative of the enduse.5.4 Applicability of this test method for other materials,including combining interference pigments with absorbing andscattering pigments
24、should be confirmed by the user.6. Environmental Conditions6.1 If the standard laboratory conditions listed belowchange during the test or from test to test by an appreciableamount, these conditions may reduce accuracy and precision ofthis test method. In some cases these effects may only beobserved
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME25392014STANDARDTESTMETHODFORMULTIANGLECOLORMEASUREMENTOFINTERFERENCEPIGMENTS 干涉 颜料 角度 颜色 测量 标准

链接地址:http://www.mydoc123.com/p-531350.html