《ASTM E2073-2007 Standard Test Method for Photopic Luminance of Photoluminescent (Phosphorescent) Markings《荧光(磷光)标志的适光亮度用标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2073-2007 Standard Test Method for Photopic Luminance of Photoluminescent (Phosphorescent) Markings《荧光(磷光)标志的适光亮度用标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 2073 07An American National StandardStandard Test Method forPhotopic Luminance of Photoluminescent (Phosphorescent)Markings1This standard is issued under the fixed designation E 2073; the number immediately following the designation indicates the year oforiginal adoption or, in the ca
2、se of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This tes
3、t method covers a procedure for determining thephotopic luminance of photoluminescent (phosphorescent)markings. It does not cover scotopic or mesopic measurements.1.2 When reference is made regarding photoluminescencein the text of this test method, it implies phosphorescence.1.3 The values stated i
4、n SI units are the standard. The valuesgiven in parentheses are provided for information purposesonly.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and he
5、alth practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E 284 Terminology of AppearanceE 308 Practice for Computing the Colors of Objects byUsing the CIE SystemE 1316 Terminology for Nondestructive ExaminationsE 2072 Specifica
6、tion for Photoluminescent (Phosphores-cent) Safety Markings2.2 Other Standards:Publication CIE No. 69 (1987) Methods of characterizingilluminance meters and luminance meters; Performance,characteristics and specifications33. Terminology3.1 Definitions of terms in Terminology E 284 and Termi-nology E
7、 1316 are applicable to this specification.4. Significance and Use4.1 To assess how photoluminescent markings performunder identical test conditions, the luminance shall be mea-sured in accordance with this test method (see SpecificationE 2072).5. Apparatus5.1 Illuminance MeterTo measure the illumin
8、ation of theactivating light source on the surface of the photoluminescentmarking, use an illuminance meter calibrated to measureilluminance in lux (fc), with the following features: spectralerror, f18, #5 %; UV response, u, #0.5 %; resolution 1.0 lux;and linearity error, f3, #0.5 % (see Public. CIE
9、 No. 69).5.2 Luminance MeterTo measure the photopic luminanceof photoluminescent markings, use a luminance meter with thefollowing minimum features (see Publication CIE No. 69):spectral error, f18, #5 %; UV response, u, #0.5 %; resolutionat least 0.1 mcd/m2; linearity error, f3,#0.5 %; signal-to-noi
10、se-ratio: at least 10:1 for all measurements. The instrument shallhave been calibrated within the preceding 12 months usingphotometric standards traceable to a national standards insti-tute.6. Sampling, Test Specimens and Test Units6.1 Method of SamplingTake a minimum of threesamples. Each sample sh
11、all be of a minimum size of at least 45mm (134 in.) in diameter. Select samples at random. If amanufacturer, samples shall be representative of the productionlot, coded and identified to correspond to production batchcodes, and shall be numbered consecutively. Paints shall beapplied in compliance wi
12、th the manufacturers applicationinstructions.1This test method is under the jurisdiction of ASTM Committee E12 on Colorand Appearance , and is the direct responsibility of Subcommittee E12.13 onPhotoluminescent Safety Markings.Current edition approved July 1, 2007. Published August 2007. Originallya
13、pproved in 2000. Last previous edition approved in 2002 as E 2073 - 02.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe AST
14、M website.3Available from U.S. National Committee of the CIE (International Commissionon Illumination), C/o Thomas M. Lemons, TLA-Lighting Consultants, Inc., 7 PondSt., Salem, MA 01970, http:/www.cie-usnc.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19
15、428-2959, United States.7. Conditioning7.1 Precondition all test specimens by placing them incomplete darkness until their residual luminance has fallen to0.3 mcd/m2or less, tested utilizing the luminance meterspecified under 5.2. Remove them immediately before per-forming the tests. No ambient or s
16、tray light shall be present.8. Procedure8.1 Ambient ConditionsThe ambient temperature duringdarkness preconditioning of specimens, activation and lumi-nance testing shall be 25 6 3C (77 6 5F). The relativehumidity shall not exceed 60 %. All luminance testing shall beperformed in a room whose ambient
17、 light level is such that theluminance of a white diffuse reflectance standard is at least onedecade lower than the lowest test specimen luminance mea-surement to be recorded.8.2 Preparation of ApparatusThe luminance meter shallbe zeroed prior to every measurement, then checked immedi-ately after th
18、e measurement and the measurement shall berejected if the zero drifted by more than 5 % of the measuredvalue. The distance between the luminance meter and themeasured test specimen, and also the aperture angle of theluminance meter, shall be chosen in such a way that 30-mm(1516-in.) diameter of the
19、photoluminescent test specimen,which is of at least 45-mm (134-in.) diameter, is evaluated.8.3 ActivationActivate the photoluminescent markingspecimens with an unfiltered fluorescent cool white source oflight having a spectral power distribution similar to cool whiteF2 as described in Practice E 308
20、 Table 4, of 40 W or less, witha correlated color temperature ranging from 4000 to 4500 K for120 min (610 s), providing an illumination of 21.6 lux (2 fc)61 % on the marking surface. The test specimen body tem-perature shall not exceed 30C 1 min after activation. Noambient or stray light shall be pr
21、esent during activation.Measure the activation with an illuminance meter as describedin 5.1.8.4 LuminanceMeasure the photopic luminance of allspecimens of the photoluminescent marking with a luminancemeter as described in 5.2 after 10 min 610 s and 60 min 610s and 90 min. 610 s.9. Report9.1 Report t
22、he following information:9.1.1 Tested in accordance with ASTM Standard _Issue: _,9.1.2 Manufacturer of tested photoluminescent marking:Name, Address, Phone, Fax,9.1.3 Specimen description: (clear item identification tomake specimens traceable to manufacturers data sheets),9.1.4 Beginning and end of
23、conditioning: (fill in days andtime),9.1.5 Date of measurement,9.1.6 Instrument parameters and photometer serial number,9.1.7 Activation: (fill in minutes, type of activating lightsource, illuminance in lux (fc),9.1.8 Ambient temperature and relative humidity,9.1.9 Photopic luminance measurement res
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME20732007STANDARDTESTMETHODFORPHOTOPICLUMINANCEOFPHOTOLUMINESCENTPHOSPHORESCENTMARKINGS 荧光 磷光 标志

链接地址:http://www.mydoc123.com/p-530213.html