1、Designation: E 1863 07Standard Test Method forAnalysis of Acrylonitrile by Gas Chromatography1This standard is issued under the fixed designation E 1863; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A
2、number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the determination of the impu-rities in, and the purity of, acrylonitrile by flame ionizationdetector gas chr
3、omatography. It is applicable to acrylonitrile inthe range of 99 to 100 % purity.1.2 The values stated in SI units are to be regarded asstandard. The values given in parentheses are for informationonly.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with i
4、ts use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific hazardstatements are given in Sections 6 and 7.1.4 Review the current MSDS for detailed informationconc
5、erning toxicity, first aid procedures, and safety precau-tions.2. Referenced Documents2.1 ASTM Standards:2E 180 Practice for Determining the Precision of ASTMMethods for Analysis and Testing of Industrial and Spe-cialty ChemicalsE 1178 Test Methods for Analysis of Acrylonitrile3. Summary of Test Met
6、hod3.1 In this test method, a representative sample of acryloni-trile is introduced in a gas chromatograph equipped with aflame ionization detector and a capillary column where specificimpurities are separated from the acrylonitrile. The chromato-graphic area for each impurity is compared to the are
7、a of theinternal standard, toluene or other suitable known, added to thesample. From response factors of these impurities relative tothat of the internal standard and the amount of the standardadded, the concentration of the impurities are calculated. Otherimpurities, such as water, are obtained by
8、use of Test MethodsE 1178. The acrylonitrile content is obtained by subtracting thetotal amount of all impurities from 100.0.4. Significance and Use4.1 This test method is designed to obtain acrylonitrilepurity on the basis of impurities normally present in acryloni-trile and may be useful for final
9、 product inspection and processcontrol.4.2 This test method will measure the following impurities:acetone, acrolein, acetonitrile, and acetaldehyde. It also willallow calibration of other impurities including benzene, meth-acrylonitrile, oxazole, propionitrile, cis-crotononitrile, trans-crotononitri
10、le, and others where specific impurity standards areavailable.5. Apparatus5.1 Capillary Gas ChromatographAny gas chromato-graph equipped with a flame ionization detector and a splitinjection system for use with capillary columns that can beoperated at the conditions given in Table 1.5.2 ColumnThe co
11、lumn, such as Supelcowax 10,3mustgive satisfactory resolution and proper peak shapes for thecomponents listed in Fig. 1.5.3 Recorder/IntegratorElectronic integration is recom-mended for this analysis.5.4 Syringe, 10 L capacity.6. Reagents and Materials6.1 Purity of ReagentsReagent grade chemicals sh
12、all beused in all tests. Unless otherwise indicated, it is intended thatall reagents conform to the specifications of the Committee onAnalytical Reagents of the American Chemical Society where1This test method is under the jurisdiction of ASTM Committee E15 onIndustrial and Specialty Chemicals and i
13、s the direct responsibility of SubcommitteeE15.02 on Product Standards.Current edition approved April 1, 2007. Published May 2007. Originallyapproved in 1997. Last previous edition approved in 2002 as E 1863 97 (2002).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact AS
14、TM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3A Supelcowax 10 fused silica capillary column (60 m by 0.32 mm ID by 1 mfilm thickness), has been found to be suitable, but similar polar wax
15、columns fromother vendors may be used after shown to be suitable.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.TABLE 1 Typical Instrument ParametersDetector: Flame i
16、onizationColumn:length: 60 minside diameter: 0.32 mmstationary phase: Supelcowax 10support: Fused silicafilm thickness, m: 1.0Temperature, Cinjector: 225detector: 350oven: 50 initial, hold 25 min, rate 10/min, 90 final, hold 20 minCarrier Gas: HeliumFlow: 20 cm/sTotal chromatograph run time: 54 minI
17、nternal standard: TolueneSample size, L 2.0Split ratio 1:100Retention times, min (refer to Fig. 1 for typical chromatogram)Acetaldehyde 6Acetone 9Acrolein 10Benzene 18Methacrylonitrile 23Oxazole 29Propionitrile 29.5Toluene 30cis-Crotononitrile 38trans-Crotononitrile 49FIG. 1 Typical Chromatogram of
18、Acrylonitrile Calibration MixtureE1863072such specifications are available.4Other grades may be used,provided it is first ascertained that the reagent is of sufficientlyhigh purity to permit its use without lessening the accuracy ofthe determination.6.2 Carrier Gas, helium minimum purity 99.995 mol
19、%.6.3 Hydrogen, high purity.6.4 Air, hydrogen free, high purity.6.5 Toluene, 99.0 % min purity or other internal standard,previously analyzed free of compounds coeluting with impu-rities in the sample.6.6 Acrylonitrile, highest purity available.NOTE 1High purity acrylonitrile can be obtained by frac
20、tional distil-lation.6.7 Acetone, at least 96 % pure.6.8 Acrolein, at least 96 % pure.6.9 Acetonitrile, at least 96 % pure.6.10 Acetaldehyde, at least 96 % pure.6.11 Benzene, at least 96 % pure.6.12 Methacrylonitrile, at least 96 % pure.6.13 Propionitrile, at least 96 % pure.6.14 Crotononitrile, cis
21、 and trans, at least 96 % pure,available only as a mixture.7. Hazards7.1 Acrylonitrile potentially is hazardous to human health ifnot properly handled. Acrylonitrile is a suspected humancarcinogen. Use acrylonitrile in a well-ventilated hood.7.2 Acrylonitrile can contribute to a toxic condition insy
22、stems of the human body, from inhalation, swallowing orcontact with the eyes or skin. Direct contact with acrylonitrilealso can cause skin burns.7.3 Acrylonitrile liquid and vapor are absorbed readily intoshoe leather and clothing and will penetrate most rubbers,barrier fabrics, or creams. Contact l
23、enses should not be worn inareas where eye contact with acrylonitrile could occur. Imper-meable protective clothing must be used. Consult the currentMSDS for recommended materials.8. Calibration and Standardization8.1 Prepare a synthetic mixture containing approximately99.4 mass % acrylonitrile and
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME18632007STANDARDTESTMETHODFORANALYSISOFACRYLONITRILEBYGASCHROMATOGRAPHY 气体 色谱 分析 丙烯腈 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-529668.html