ASTM E1740-2015 Standard Test Method for Determining the Heat Release Rate and Other Fire-Test-Response Characteristics of Wall Covering or Ceiling Covering Composites Using a Cone.pdf
《ASTM E1740-2015 Standard Test Method for Determining the Heat Release Rate and Other Fire-Test-Response Characteristics of Wall Covering or Ceiling Covering Composites Using a Cone.pdf》由会员分享,可在线阅读,更多相关《ASTM E1740-2015 Standard Test Method for Determining the Heat Release Rate and Other Fire-Test-Response Characteristics of Wall Covering or Ceiling Covering Composites Using a Cone.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1740 10E1740 15 An American National StandardStandard Test Method forDetermining the Heat Release Rate and OtherFire-Test-Response Characteristics of Wall Covering orCeiling Covering Composites Using a Cone Calorimeter1This standard is issued under the fixed designation E1740; the numb
2、er immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCT
3、IONThis test method provides a means for measuring the fire-test-response characteristics of wallcoverings, ceiling coverings, wall covering composites, and ceiling covering composites using abench-scale oxygen consumption calorimeter.1. Scope Scope*1.1 This fire-test-response test method covers det
4、ermination of the ignitability and heat release rate of composites consisting ofa wall covering or ceiling covering, a substrate, and all laminating adhesives, coatings, and finishes. Heat release informationcannot be used alone to evaluate the flammability of wall coverings or ceiling coverings. Th
5、e data are intended to be used formodeling or with other data to evaluate a material.1.2 This test method provides for measurement of the time to sustained flaming, heat release rate, peak and total heat release,and effective heat of combustion at a constant initial test heat flux of 35 kW/m2. Heat
6、release data at different heat fluxes are alsoobtained by this test method. The specimen is oriented horizontally, and a spark ignition source is used.1.3 The fire-test-response characteristics are determined using the apparatus and procedures described in Test Method E1354.1.4 The tests are conduct
7、ed on bench-scale specimens combining the components used in the actual installation.1.5 The values stated in SI units are to be regarded as the standard. See IEEE/ASTM SI-10.1.6 Fire testing of products and materials is inherently hazardous, and adequate safeguards for personnel and property shall
8、beused in conducting these tests. This test method potentially involves hazardous materials, operations, and equipment.1.7 This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame undercontrolled conditions, but does not by itself incorporate
9、 all factors required for fire hazard or fire risk assessment of the materials,products, or assemblies under actual fire conditions.1.8 Fire testing of products and materials is inherently hazardous, and adequate hazardous. Adequate safeguards for personneland property shall be employed in conductin
10、g these tests. This test method may involve hazardous materials, operations, andequipment. Specific information about hazard is given in Section 6.1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this st
11、andard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C1186 Specification for Flat Fiber-Cement SheetsD123 Terminology Relating to Textiles1 This test method is under the jurisdicti
12、on ofASTM Committee E05 on Fire Standards and is the direct responsibility of Subcommittee E05.21 on Smoke and CombustionProducts.Current edition approved Aug. 1, 2010April 1, 2015. Published September 2010May 2015. Originally approved in 1995. Last previous edition approved in 20092010 asE1740 09.E
13、1740 10. DOI: 10.1520/E1740-10.10.1520/E1740-15.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document
14、 is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appr
15、opriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United Sta
16、tes1D5865 Test Method for Gross Calorific Value of Coal and CokeE84 Test Method for Surface Burning Characteristics of Building MaterialsE176 Terminology of Fire StandardsE603 Guide for Room Fire ExperimentsE906 Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using a
17、Thermopile MethodE1354 Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen ConsumptionCalorimeterE1474 Test Method for Determining the Heat Release Rate of Upholstered Furniture and Mattress Components or CompositesUsing a Bench Scale Oxygen Consumption Ca
18、lorimeterIEEE/ASTM SI-10 American National Standard for Use of the International System of Units (SI): The Modern Metric System2.2 NFPA Standard:3NFPA 265 Standard Methods of Fire Tests for Evaluating Room Fire Growth Contribution of Textile Wall CoveringNFPA 286 Standard Method of Fire Test for Eva
19、luating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth2.3 ISO Standards:4ISO 4880 Burning Behaviour of Textiles and Textile ProductsVocabularyISO 5660 Fire TestsReaction to FirePart 1: Rate of Heat Release from Building Products (Cone Calorimeter Method)ISO 13943 Fire SafetyVoc
20、abulary3. Terminology3.1 DefinitionsFor definitions of terms used in this test method and associated with fire issues, refer to Terminology E176 andISO 13943. The definitions given in Terminology E176 shall prevail in case of conflict. For definitions of terms used in this testmethod and associated
21、with textile issues, refer to Terminology D123 and ISO 4880. The definitions given in Terminology D123shall prevail in case of conflict.3.1.1 effective heat of combustion, nthe amount of heat generated per unit mass lost by a material, product, or assembly, whenexposed to specific fire test conditio
22、ns (see gross heat of combustion).3.1.1.1 DiscussionThe effective heat of combustion depends on the test method and is determined by dividing the measured heat release by the massloss during a specified period of time under the specified test conditions. Typically, the specified fire test conditions
23、 are providedby the specifications of the fire test standard that cites effective heat of combustion as a quantity to be measured. For certain firetest conditions, involving very high heat and high oxygen concentrations under high pressure, the effective heat of combustion willapproximate the gross
24、heat of combustion. More often, the fire test conditions will represent or approximate certain real fireexposure conditions, and the effective heat of combustion is the appropriate measure. Typical units are kJ/g or MJ/kg.3.1.2 gross heat of combustion, nthe maximum amount of heat per unit mass that
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME17402015STANDARDTESTMETHODFORDETERMININGTHEHEATRELEASERATEANDOTHERFIRETESTRESPONSECHARACTERISTICSOFWALLCOVERINGORCEILINGCOVERINGCOMPOSITESUSINGACONEPDF

链接地址:http://www.mydoc123.com/p-529358.html