ASTM E1740-2007a Standard Test Method for Determining the Heat Release Rate and Other Fire-Test-Response Characteristics of Wallcovering Composites Using a Cone Calorimeter《用锥形热量计测.pdf
《ASTM E1740-2007a Standard Test Method for Determining the Heat Release Rate and Other Fire-Test-Response Characteristics of Wallcovering Composites Using a Cone Calorimeter《用锥形热量计测.pdf》由会员分享,可在线阅读,更多相关《ASTM E1740-2007a Standard Test Method for Determining the Heat Release Rate and Other Fire-Test-Response Characteristics of Wallcovering Composites Using a Cone Calorimeter《用锥形热量计测.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 1740 07aAn American National StandardStandard Test Method forDetermining the Heat Release Rate and OtherFire-Test-Response Characteristics of WallcoveringComposites Using a Cone Calorimeter1This standard is issued under the fixed designation E 1740; the number immediately following th
2、e designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.INTRODUCTIONThis test method provid
3、es a means for measuring the fire-test-response characteristics ofwallcoverings and wallcovering composites using a bench-scale oxygen consumption calorimeter.1. Scope1.1 This fire-test-response test method covers determinationof the ignitability and heat release rate of composites consistingof a wa
4、llcovering, a substrate, and all laminating adhesives,coatings, and finishes. Heat release information cannot be usedalone to evaluate the flammability of wallcoverings. The dataare intended to be used for modeling or with other data toevaluate a material.1.2 This test method provides for measuremen
5、t of the timeto sustained flaming, heat release rate, peak and total heatrelease, and effective heat of combustion at a constant radiantheat flux of 35 kW/m2. Heat release data at different heatingfluxes are also obtained by this test method. The specimen isoriented horizontally, and a spark ignitio
6、n source is used.1.3 The fire-test-response characteristics are determinedusing the apparatus and procedures described in Test MethodE 1354.1.4 The tests are conducted on bench-scale specimenscombining the components used in the actual installation.1.5 The values stated in SI units are to be regarde
7、d as thestandard. See IEEE/ASTM SI-10.1.6 Fire testing of products and materials is inherentlyhazardous, and adequate safeguards for personnel and propertyshall be used in conducting these tests. This test methodpotentially involves hazardous materials, operations, andequipment.1.7 This standard is
8、used to measure and describe theresponse of materials, products, or assemblies to heat andflame under controlled conditions, but does not by itselfincorporate all factors required for fire hazard or fire riskassessment of the materials, products, or assemblies underactual fire conditions.1.8 Fire te
9、sting of products and materials is inherentlyhazardous, and adequate safeguards for personnel and prop-erty shall be employed in conducting these tests. This testmethod may involve hazardous materials, operations, andequipment. Specific information about hazard is given inSection 6.1.9 This standard
10、 does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM
11、Standards:2C 1186 Specification for Flat Non-Asbestos Fiber-CementSheetsD 123 Terminology Relating to TextilesE84 Test Method for Surface Burning Characteristics ofBuilding MaterialsE 176 Terminology of Fire StandardsE 1354 Test Method for Heat and Visible Smoke ReleaseRates for Materials and Produc
12、ts Using an Oxygen Con-sumption CalorimeterE 1474 Test Method for Determining the Heat Release Rateof Upholstered Furniture and Mattress Components orComposites Using a Bench Scale Oxygen ConsumptionCalorimeter1This test method is under the jurisdiction of ASTM Committee E05 on FireStandards and is
13、the direct responsibility of Subcommittee E05.21 on Smoke andCombustion Products.Current edition approved Oct. 1, 2007. Published October 2007. Originallyapproved in 1995. Last previous edition approved in 2007 as E 1740 07.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcont
14、act ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.IEEE/ASTM SI-10 Americ
15、an National Standard for Use ofthe International System of Units (SI): The Modern MetricSystem2.2 NFPA Standard:3NFPA 265 Standard Methods of Fire Tests for EvaluatingRoom Fire Growth Contribution of Textile Wall Covering2.3 ISO Standards:4ISO 4880 Burning Behaviour of Textiles and TextileProductsVo
16、cabularyISO 5660 Fire TestsReaction to FirePart 1: Rate ofHeat Release from Building Products (Cone CalorimeterMethod)ISO 13943 Fire SafetyVocabulary3. Terminology3.1 DefinitionsFor definitions of terms used in this testmethod and associated with fire issues, refer to TerminologyE 176 and ISO 13943.
17、 The definitions given in TerminologyE 176 shall prevail in case of conflict. For definitions of termsused in this test method and associated with textile issues, referto Terminology D 123 and ISO 4880. The definitions given inTerminology D 123 shall prevail in case of conflict.3.1.1 effective heat
18、of combustion, nthe amount of heatgenerated per unit mass lost by a material, product, orassembly, when exposed to specific fire test conditions (seegross heat of combustion).3.1.1.1 DiscussionThe effective heat of combustion de-pends on the test method and is determined by dividing themeasured heat
19、 release by the mass loss during a specifiedperiod of time under the specified test conditions. Typically, thespecified fire test conditions are provided by the specificationsof the fire test standard that cites effective heat of combustionas a quantity to be measured. For certain fire test conditio
20、ns,involving very high heat and high oxygen concentrations underhigh pressure, the effective heat of combustion will approxi-mate the gross heat of combustion. More often, the fire testconditions will represent or approximate certain real fireexposure conditions, and the effective heat of combustion
21、 is theappropriate measure. Typical units are kJ/g or MJ/kg.3.1.2 oxygen consumption principlethe expression of therelationship between the mass of oxygen consumed duringcombustion and the heat released.3.2 Definitions of Terms Specific to This Standard:3.2.1 heat release ratethe heat evolved from t
22、he speci-men, expressed per unit area of exposed specimen area per unitof time.3.2.2 heating fluxthe prescribed incident flux imposedexternally from the heater onto the specimen at the initiation ofthe test.3.2.2.1 DiscussionThe specimen, once ignited, also isheated by its own flame. This differs fr
23、om the generic definitionof heat flux in Terminology E 176, because in this test methodthe heating flux of primary interest is the one imposed at theinitiation of the test.3.2.3 ignitabilitythe propensity for ignition, as measuredby the time to sustained flaming at a specified heating flux.3.2.4 net
24、 heat of combustionthe oxygen bomb calorimetervalue for the heat of combustion, corrected for the gaseousstate of product water.3.2.5 orientationthe plane in which the exposed face ofthe specimen is located during testing, which is horizontalfacing up for this test.3.2.6 sustained flamingthe existen
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME17402007ASTANDARDTESTMETHODFORDETERMININGTHEHEATRELEASERATEANDOTHERFIRETESTRESPONSECHARACTERISTICSOFWALLCOVERINGCOMPOSITESUSINGACONECALORIMETER

链接地址:http://www.mydoc123.com/p-529355.html