ASTM E1637-1998(2003) Standard Specification for Structural Standing Seam Aluminum Roof Panel Systems《结构固定接缝铝屋顶镶板系统的标准规范》.pdf
《ASTM E1637-1998(2003) Standard Specification for Structural Standing Seam Aluminum Roof Panel Systems《结构固定接缝铝屋顶镶板系统的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1637-1998(2003) Standard Specification for Structural Standing Seam Aluminum Roof Panel Systems《结构固定接缝铝屋顶镶板系统的标准规范》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 1637 98 (Reapproved 2003)Standard Specification forStructural Standing Seam Aluminum Roof Panel Systems1This standard is issued under the fixed designation E 1637; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers the design, construction, andweatherability of structural standing seam aluminum ro
3、of panelsystems. It includes performance requirements for the follow-ing elements only: panels, concealed panel clips, panel/clipanchorage, and panel joint sealers.NOTE 1These systems are used on both low-slope and steep-sloperoof applications. They also are used with or without an underlying deckor
4、 sheathing.1.2 The objective of this specification is to provide for theoverall performance of the structural standing seam aluminumroof panel system as defined in 3.2.6 during its service life inorder to provide weather protection, carry the specified designloads, and allow proper access over the r
5、oof surface in order toprovide for periodic maintenance of the equipment by thebuilding owner.1.3 In addition to structural characteristics, the specifiershall evaluate other characteristics beyond the scope of thisspecification that affect the final choice of roof construction.These include, but ar
6、e not limited to, functional, legal, insur-ance, and economic considerations. See Appendix X1 for thespecifiers checklist.1.4 This specification is not intended to exclude products orsystems not covered by the referenced documents.1.5 The values stated in inch-pound units are to be regardedas the st
7、andard. The values given in parentheses are forinformation only.1.6 The text of this specification contains notes and foot-notes that provide explanatory information and are not require-ments of this specification.2. Referenced Documents2.1 ASTM Standards:B 209 Specification for Aluminum and Aluminu
8、m-AlloySheet and Plate2C711 Test Method for Low-Temperature Flexibility andTenacity of One-Part, Elastomeric, Solvent-Release TypeSealants2C 765 Test Method for Low-Temperature Flexibility ofPreformed Tape Sealants2C 879 Test Method for Release Papers Used with Pre-formed Tape Sealants2D 1667 Specif
9、ication for Flexible Cellular MaterialsVinyl Chloride Polymers and Copolymers (Closed-CellForm)2D 3310 Test Method for Determining Corrosivity of Adhe-sive Metals2E 631 Terminology of Building Constructions2E 1592 Test Method for Structural Performance of SheetMetal Roof and Siding Systems by Unifor
10、m Static AirPressure Difference2E 1646 Test Method forWater Penetration of Exterior MetalRoof Panel Systems by Uniform Static Air PressureDifference2E 1680 Test Method for Rate of Air Leakage ThroughExterior Metal Roof Panel Systems2G21 Practice for Determining Resistance of SyntheticPolymeric Mater
11、ials to Fungi22.2 Factory Mutual Research Corporation Standard:Approval Standard Class 1 Panel Roofs Class No. 447132.3 Underwriters Laboratories Standard:UL 580, Standard for Safety, Tests for Uplift Resistance ofRoof Assemblies42.4 Aluminum Association Document:Aluminum Design Manual, Latest Editi
12、on52.5 AISI Document:Cold-Formed Steel Design Manual, Latest Edition62.6 MBMA Document:MBMA Low Rise Building Systems Manual, Latest Edi-tion71This specification is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.57on Perfo
13、rmance of Metal Roof Systems.Current edition approved Oct. 1, 2003. Published October 2003. Originallyapproved in 1994. Last previous edition approved in 1998 as E 1637 98.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For An
14、nual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Factory Mutual Research Corp., P.O. Box 688, Norwood, MA02062.4Available from Underwriters Laboratories, 333 Pfingsten Rd., Northbrook, IL60062.5Available from Aluminum Assn
15、., 818 Connecticut Ave., NW, Washington, DC20006.6Available from American Iron and Steel Institute (AISI), 1101 17th St., NW,Suite 1300, Washington, DC 20036.7Available from Metal Building Manufacturers Assn., Inc., 1300 SummerAvenue, Cleveland, OH 44115-2851.1Copyright ASTM International, 100 Barr
16、Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.2.7 ASHRAE Document:1997 ASHRAE Handbook, Fundamentals82.8 National Climatic Center Document:1981 B Climatography of U.S. #8193. Terminology3.1 Definitions:3.1.1 Refer to the latest edition of the MBMA Low RiseBuilding System
17、s Manual and Terminology E 631 for defini-tions of terms used in this specification.3.2 Descriptions of Terms Specific to This Standard:3.2.1 construction loads, nthose loads encountered duringthe erection of the roof system only.3.2.2 fixing line, na line or adjacent lines of fixed points.3.2.3 mai
18、ntenance loads, nloads including, but not lim-ited to, personnel, equipment, and materials required to main-tain functionality of the building.3.2.4 oil canning, na waviness that occurs in flat areas ofmetal.3.2.5 sealer, nany material that is used to seal cracks,joints, or laps.3.2.6 structural sta
19、nding seam aluminum roof panel system,nan aluminum roof system designed to resist positive andnegative loads applied normal to the panel surface without thebenefit of a supporting deck or sheathing.3.2.7 thermal movement, nthe reaction of the roof systemin response to changes in the panel temperatur
20、e.4. Performance Requirements4.1 DesignThe roof system shall be designed for specifieddesign loads and thermal effects.4.1.1 Minimum environmental design loads shall be deter-mined by the governing code or the design professional.4.1.2 The finished roof system shall be capable of sustaininga minimum
21、 200-lb (0.9-kN) concentrated load on any 12-in. by12-in. (300-mm by 300-mm) area of finished roof withoutcausing seam separation, permanent panel buckling, or loss ofweathertightness.4.1.3 Thermal movement shall be provided for in accor-dance with Sections 7 and 8. Temperature extremes for manyloca
22、lities are found in documents referenced in 2.6-2.8.4.1.4 The standing seam roof system clips do not alwaysprovide full lateral support to secondary structural members.The degree of lateral support provided to the secondarystructural members by the panel system shall be determined byan appropriate t
23、est, or in the absence of such test, the panelmust be assumed to provide no lateral support.NOTE 2The Base Test Method for Purlins Supporting a StandingSeam Roof System in theAISI Cold-Formed Steel Design Manual is usedto evaluate lateral support when the secondary structural is cold-formedZee or Ce
24、e purlins.4.2 Protection of Incompatible MaterialsComponentsconstructed of incompatible materials shall not be placedtogether without an effective separating material.4.3 Oil CanningOil canning is an inherent characteristicof products covered by this specification, particularly thosewith broad, flat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME163719982003STANDARDSPECIFICATIONFORSTRUCTURALSTANDINGSEAMALUMINUMROOFPANELSYSTEMS 结构 固定 接缝 屋顶 镶板

链接地址:http://www.mydoc123.com/p-529095.html