ASTM E1354-2017 Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter《采用耗氧热量计的材料与产品热和可视烟雾释放率的标准试验方法》.pdf
《ASTM E1354-2017 Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter《采用耗氧热量计的材料与产品热和可视烟雾释放率的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1354-2017 Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter《采用耗氧热量计的材料与产品热和可视烟雾释放率的标准试验方法》.pdf(34页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1354 16aE1354 17 An American National StandardStandard Test Method forHeat and Visible Smoke Release Rates for Materials andProducts Using an Oxygen Consumption Calorimeter1This standard is issued under the fixed designation E1354; the number immediately following the designation indic
2、ates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope Scope*1.1 This fire-test-response standard pro
3、vides for measuring the response of materials exposed to controlled levels of radiantheating with or without an external ignitor.1.2 This test method is used to determine the ignitability, heat release rates, mass loss rates, effective heat of combustion, andvisible smoke development of materials an
4、d products.1.3 The rate of heat release is determined by measurement of the oxygen consumption as determined by the oxygenconcentration and the flow rate in the exhaust product stream. The effective heat of combustion is determined from a concomitantmeasurement of specimen mass loss rate, in combina
5、tion with the heat release rate. Smoke development is measured byobscuration of light by the combustion product stream.1.4 Specimens shall be exposed to initial test heat fluxes in the range of 0 to 100 kW/m2. External ignition, when used, shallbe by electric spark. The value of the initial test hea
6、t flux and the use of external ignition are to be as specified in the relevantmaterial or performance standard (see X1.2). The normal specimen testing orientation is horizontal, independent of whether theend-use application involves a horizontal or a vertical orientation. The apparatus also contains
7、 provisions for vertical orientationtesting; this is used for exploratory or diagnostic studies only.1.5 Ignitability is determined as a measurement of time from initial exposure to time of sustained flaming.1.6 This test method has been developed for use for material and product evaluations, mathem
8、atical modeling, design purposes,or development and research. Examples of material specimens include portions of an end-use product or the various componentsused in the end-use product.1.7 The values stated in SI units are to be regarded as standard. No other units of measurement are included in thi
9、s standard.1.8 This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame undercontrolled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials,products, or assemblies under
10、 actual fire conditions.1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior
11、to use. For specific hazard statements, see Section 7.1.10 Fire testing is inherently hazardous. Adequate safeguards for personnel and property shall be employed in conductingthese tests.1.11 This international standard was developed in accordance with internationally recognized principles on standa
12、rdizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D5865 Test Method for Gross Calorific Value of Co
13、al and Coke1 This test method is under the jurisdiction ofASTM Committee E05 on Fire Standardsand is the direct responsibility of Subcommittee E05.21 on Smoke and CombustionProducts.Current edition approved May 1, 2016July 1, 2017. Published May 2016August 2017. Originally approved in 1990. Last pre
14、vious edition approved in 2016 asE1354 - 16.E1354 - 16a. DOI: 10.1520/E1354-16A.10.1520/E1354-17.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Docume
15、nt Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM rec
16、ommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C
17、700, West Conshohocken, PA 19428-2959. United States1E176 Terminology of Fire StandardsE177 Practice for Use of the Terms Precision and Bias in ASTM Test MethodsE603 Guide for Room Fire ExperimentsE662 Test Method for Specific Optical Density of Smoke Generated by Solid MaterialsE691 Practice for Co
18、nducting an Interlaboratory Study to Determine the Precision of a Test MethodE906 Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using a Thermopile Method2.2 ISO Standards:3ISO 5657-1986(E) Fire Testsreaction to fireignitability of building materialsISO 5660-1(2015)
19、Reaction-to-fire tests Heat release, smoke production and mass loss rate Part 1: Heat release rate (conecalorimeter method) and smoke production rate (dynamic measurement)ISO 5725-2 (1994) Accuracy (trueness and precision) of measurement methods and results Part 2: Basic method for thedetermination
20、of repeatability and reproducibility of a standard measurement methodISO 9705-1 (2016) Reaction to fire tests Room corner test for wall and ceiling lining products Part 1: Test method for a smallroom configuration3. Terminology3.1 DefinitionsFor definitions of terms used in this test method, refer t
21、o Terminology E176.3.2 Definitions of Terms Specific to This Standard:3.2.1 critical heat flux for ignition, nthe midpoint within the range of heat fluxes between the maximum (highest) heat fluxthat produces no ignition and the minimum (lowest) heat flux that produces ignition, for a specified expos
22、ure time.3.2.2 effective heat of combustion, nthe amount of heat generated per unit mass lost by a material, product or assembly, whenexposed to specific fire test conditions (contrast gross heat of combustion).3.2.2.1 DiscussionThe effective heat of combustion depends on the test method and is dete
23、rmined by dividing the measured heat release by the massloss during a specified period of time under the specified test conditions.Typically, the specified fire test conditions are providedby the specifications of the fire test standard that cites effective heat of combustion as a quantity to be mea
24、sured. For certain firetest conditions, involving very high heat and high oxygen concentrations under high pressure, the effective heat of combustion willapproximate the gross heat of combustion. More often, the fire test conditions will represent or approximate certain real fireexposure conditions,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME13542017STANDARDTESTMETHODFORHEATANDVISIBLESMOKERELEASERATESFORMATERIALSANDPRODUCTSUSINGANOXYGENCONSUMPTIONCALORIMETER

链接地址:http://www.mydoc123.com/p-528525.html