ASTM E1228-2017 Standard Test Method for Assay of Peroxy Esters&x2014 Catalyzed Iodometric Procedure《过氧脂化验分析的标准试验方法 催化碘滴定法》.pdf
《ASTM E1228-2017 Standard Test Method for Assay of Peroxy Esters&x2014 Catalyzed Iodometric Procedure《过氧脂化验分析的标准试验方法 催化碘滴定法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1228-2017 Standard Test Method for Assay of Peroxy Esters&x2014 Catalyzed Iodometric Procedure《过氧脂化验分析的标准试验方法 催化碘滴定法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1228 09E1228 17Standard Test Method forAssay of Peroxy EstersCatalyzed Iodometric Procedure1This standard is issued under the fixed designation E1228; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last r
2、evision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the assay of organic peroxides of the peroxy ester type.NOTE 1Other test methods for the assay of o
3、rganic peroxides are given in Test Methods E298, E475, and E755.1.2 Review the current material safety data sheets (MSDS)(SDS) for detailed information concerning toxicity, first aidprocedures, and safety precautions.1.3 The values stated in SI units are to be regarded as the standard. No other unit
4、s of measurement are included in this testmethod.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of reg
5、ulatorylimitations prior to use. Specific hazards statements are given in Section 9.1.5 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decision on Principles for the Development of International Standards, Guide
6、s and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent WaterD6809 Guide for Quality Control and Quality Assurance Procedures for Aromatic Hydrocarbons and Related MaterialsE180
7、 Practice for Determining the Precision of ASTM Methods for Analysis and Testing of Industrial and Specialty Chemicals(Withdrawn 2009)3E200 Practice for Preparation, Standardization, and Storage of Standard and Reagent Solutions for Chemical AnalysisE298 Test Methods for Assay of Organic PeroxidesE4
8、75 Test Method for Assay of Di-tert-Butyl Peroxide Using Gas ChromatographyE755 Test Method for Dicumyl Peroxide, Assay (Liquid Chromatography) (Withdrawn 2016)33. Terminology3.1 Definitions:3.1.1 active oxygenthe oxidizing power present in organic peroxides expressed as oxygen (equivalent weight 8.
9、00).4. Summary of Test Method4.1 A sample is dissolved in a mixture of isopropyl alcohol, acetic acid, and cupric chloride. A solution of potassium iodide isadded and the mixture is briefly heated, then allowed to react in the dark at room temperature for 30 min. The cupric ion catalyzesthe reductio
10、n of the peroxide and the liberated iodine is titrated with standard sodium thiosulfate solution.5. Significance and Use5.1 Peroxy esters are widely used as chemical intermediates, catalysts, and initiators. This test method provides a procedure forassaying peroxy esters to determine if they are sui
11、table for their intended use.1 This test method is under the jurisdiction of ASTM Committee D16 on Aromatic Hydrocarbons Aromatic, Industrial, Specialty and Related Chemicals and is the directresponsibility of Subcommittee D16.15 on Industrial and Specialty General Standards.Current edition approved
12、 April 1, 2009June 1, 2017. Published April 2009July 2017. Originally approved in 1988. Last previous edition approved in 20032009 asE1228 94 (2003)E1228 09.1. DOI: 10.1520/E1228-09.10.1520/E1228-17.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service
13、at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 The last approved version of this historical standard is referenced on www.astm.org.This document is not an ASTM standard and is intended only to provide the us
14、er of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard a
15、s published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States16. Interferences6.1 Conjugated diolefins interfere under th
16、e conditions of analysis by absorbing iodine.7. Apparatus7.1 Iodine Flasks, 250-mL capacity, with stoppers.NOTE 2All glassware should be cleaned thoroughly with dichromate cleaning solution before use.7.2 Beakers, 1-mL capacity, glass or PTFE.7.3 Buret, 50-mL capacity, graduated in 0.1-mL subdivisio
17、ns.7.4 Water Bath, maintained at 60C.8. Reagents8.1 Purity of ReagentsReagent grade chemicals shall be used in all tests. Unless otherwise indicated, it is intended that allreagents shall conform to the Specifications of the Committee on Analytical Reagents of the American Chemical Society, wheresuc
18、h specifications are available.4 Other grades may be used, provided it is first ascertained that the reagent is of sufficiently highpurity to permit its use without lessening the accuracy of the determination.8.2 Purity of WaterUnless otherwise indicated, references to water shall be understood to m
19、ean Type II or III reagent waterconforming to Specification D1193.8.3 Acetic Acid, glacial.8.4 Isopropyl Alcohol.8.5 Hydrochloric Acid, (1:100)Dilute 1.0 mL of concentrated hydrochloric acid (HCl) to 100 mL with water.8.6 Cupric Chloride Solution, 1 %Dilute 1.0 g of anhydrous cupric chloride (CuCl2)
20、 to 100 mL with water. Add 1.0 mL of1:100 HCl and mix. The solution should be clear.8.7 Potassium Iodide Solution, 50 %Dissolve 25 g of potassium iodide (KI) in 25 mLof de-aerated water. This reagent shouldbe freshly prepared just prior to use.8.8 Sodium Thiosulfate Standard Solution, (0.1 meq/mL)Pr
21、epare and standardize in accordance with the appropriate sectionsof Practice E200.8.9 Nitrogen Gas, oxygen-free.9. Hazards9.1 Organic peroxides are strong oxidizing agents and present potential fire and explosion hazards.Avoid contact with reducingagents and sources of heat, sparks, or open flames.
22、Reactivity varies widely and some compounds may explode when shocked.Organic peroxides are irritating to the skin, eyes, and mucous membranes. Avoid bodily contact and handle only in awell-ventilated area.10. Procedure10.1 Add 50 mL of isopropyl alcohol and 15 mL of acetic acid to a 250-mL iodine fl
23、ask. A graduate can be used for theseadditions.10.2 Pipet 1.00 mL of 1 % cupric chloride solution into the flask. (WarningThe quantity of the cupric chloride catalystsolution must be carefully measured in order to obtain reproducible results as the reagent also reacts with iodide to liberate iodinea
24、ccording to the following Eq 1:2Cu1114I 22CuI1I2 (1)The blank titration should be approximately 1.0 mL. The results should be discarded and the analysis repeated if a significantly higher blank value isobtained.)10.3 Sparge the solution with a rapid flow of nitrogen for 2 min, then stopper the flask
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME12282017STANDARDTESTMETHODFORASSAYOFPEROXYESTERSX2014CATALYZEDIODOMETRICPROCEDURE 过氧 化验 分析 标准 试验

链接地址:http://www.mydoc123.com/p-528217.html