ASTM E1228-2009 Standard Test Method for Assay of Peroxy Esters-Catalyzed Iodometric Procedure《过氧化脂质化验分析的标准试验方法 催化碘滴定法》.pdf
《ASTM E1228-2009 Standard Test Method for Assay of Peroxy Esters-Catalyzed Iodometric Procedure《过氧化脂质化验分析的标准试验方法 催化碘滴定法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1228-2009 Standard Test Method for Assay of Peroxy Esters-Catalyzed Iodometric Procedure《过氧化脂质化验分析的标准试验方法 催化碘滴定法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 1228 09Standard Test Method forAssay of Peroxy EstersCatalyzed Iodometric Procedure1This standard is issued under the fixed designation E 1228; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisio
2、n. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the assay of organic peroxidesof the peroxy ester type.NOTE 1Other test methods for the assay of organic
3、peroxides aregiven in Test Methods E 298, E 475, and E 755.1.2 Review the current material safety data sheets (MSDS)for detailed information concerning toxicity, first aid proce-dures, and safety precautions.1.3 The values stated in SI units are to be regarded as thestandard. No other units of measu
4、rement are included in thistest method.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory l
5、imitations prior to use. Specific hazardsstatements are given in Section 9.2. Referenced Documents2.1 ASTM Standards:2D 1193 Specification for Reagent WaterE 180 Practice for Determining the Precision of ASTMMethods for Analysis and Testing of Industrial and Spe-cialty ChemicalsE 200 Practice for Pr
6、eparation, Standardization, and Stor-age of Standard and Reagent Solutions for ChemicalAnalysisE 298 Test Methods for Assay of Organic PeroxidesE 475 Test Method for Assay of Di-tert-Butyl PeroxideUsing Gas ChromatographyE 755 Test Method for Dicumyl Peroxide, Assay (LiquidChromatography)3. Terminol
7、ogy3.1 Definitions:3.1.1 active oxygenthe oxidizing power present in organicperoxides expressed as oxygen (equivalent weight 8.00).4. Summary of Test Method4.1 A sample is dissolved in a mixture of isopropyl alcohol,acetic acid, and cupric chloride. A solution of potassium iodideis added and the mix
8、ture is briefly heated, then allowed to reactin the dark at room temperature for 30 min. The cupric ioncatalyzes the reduction of the peroxide and the liberated iodineis titrated with standard sodium thiosulfate solution.5. Significance and Use5.1 Peroxy esters are widely used as chemical intermedi-
9、ates, catalysts, and initiators. This test method provides aprocedure for assaying peroxy esters to determine if they aresuitable for their intended use.6. Interferences6.1 Conjugated diolefins interfere under the conditions ofanalysis by absorbing iodine.7. Apparatus7.1 Iodine Flasks, 250-mL capaci
10、ty, with stoppers.NOTE 2All glassware should be cleaned thoroughly with dichromatecleaning solution before use.7.2 Beakers, 1-mL capacity, glass or PTFE.7.3 Buret, 50-mL capacity, graduated in 0.1-mL subdivi-sions.7.4 Water Bath, maintained at 60C.8. Reagents8.1 Purity of ReagentsReagent grade chemi
11、cals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the Specifications of the Com-mittee on Analytical Reagents of the American Chemical1This test method is under the jurisdiction of ASTM Committee E15 onIndustrial and Specialty Chemicals and
12、is the direct responsibility of SubcommitteeE15.01 on General Standards.Current edition approved April 1, 2009. Published April 2009. Originallyapproved in 1988. Last previous edition approved in 2003 as E 1228 - 94(2003)1.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orconta
13、ct ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West
14、Conshohocken, PA 19428-2959, United States.Society, where such specifications are available.3Other gradesmay be used, provided it is first ascertained that the reagent isof sufficiently high purity to permit its use without lesseningthe accuracy of the determination.8.2 Purity of WaterUnless otherwi
15、se indicated, referencesto water shall be understood to mean Type II or III reagentwater conforming to Specification D 1193.8.3 Acetic Acid, glacial.8.4 Isopropyl Alcohol.8.5 Hydrochloric Acid, (1:100)Dilute 1.0 mL of concen-trated hydrochloric acid (HCl) to 100 mL with water.8.6 Cupric Chloride Sol
16、ution, 1 %Dilute 1.0 g of anhy-drous cupric chloride (CuCl2) to 100 mL with water. Add 1.0mL of 1:100 HCl and mix. The solution should be clear.8.7 Potassium Iodide Solution, 50 %Dissolve 25 g ofpotassium iodide (KI) in 25 mL of de-aerated water. Thisreagent should be freshly prepared just prior to
17、use.8.8 Sodium Thiosulfate Standard Solution, (0.1 meq/mL)Prepare and standardize in accordance with the appropriatesections of Practice E 200.8.9 Nitrogen Gas, oxygen-free.9. Hazards9.1 Organic peroxides are strong oxidizing agents andpresent potential fire and explosion hazards.Avoid contact withr
18、educing agents and sources of heat, sparks, or open flames.Reactivity varies widely and some compounds may explodewhen shocked. Organic peroxides are irritating to the skin,eyes, and mucous membranes.Avoid bodily contact and handleonly in a well-ventilated area.10. Procedure10.1 Add 50 mL of isoprop
19、yl alcohol and 15 mL of aceticacid to a 250-mL iodine flask. A graduate can be used for theseadditions.10.2 Pipet 1.00 mL of 1 % cupric chloride solution into theflask. (WarningThe quantity of the cupric chloride catalystsolution must be carefully measured in order to obtain repro-ducible results as
20、 the reagent also reacts with iodide to liberateiodine according to the following Eq 1:2Cu111 4I22 CuI 1 I2(1)The blank titration should be approximately 1.0 mL. The results should bediscarded and the analysis repeated if a significantly higher blank value isobtained.)10.3 Sparge the solution with a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME12282009STANDARDTESTMETHODFORASSAYOFPEROXYESTERSCATALYZEDIODOMETRICPROCEDURE 过氧化 化验 分析 标准 试验 方法

链接地址:http://www.mydoc123.com/p-528216.html