ASTM E1111 E1111M-2014 Standard Test Method for Measuring the Interzone Attenuation of Open Office Components《测量敞式办公部件区间衰减的标准试验方法》.pdf
《ASTM E1111 E1111M-2014 Standard Test Method for Measuring the Interzone Attenuation of Open Office Components《测量敞式办公部件区间衰减的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1111 E1111M-2014 Standard Test Method for Measuring the Interzone Attenuation of Open Office Components《测量敞式办公部件区间衰减的标准试验方法》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1111/E1111M 14Standard Test Method forMeasuring the Interzone Attenuation of Open OfficeComponents1This standard is issued under the fixed designation E1111/E1111M; the number immediately following the designation indicates the yearof original adoption or, in the case of revision, the
2、year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONThis test method describes the measurement and evaluation of acoustical performance ofcomponents affecting spe
3、ech privacy in open-plan spaces. The maximum privacy theoreticallyavailable at normal working distances in open-plan spaces, with partial height space dividers (screens),is insufficient without the assistance of relatively elevated background masking sound levels. Thus, theprovision of adequate spee
4、ch privacy in open-plan offices and schools is one of the most difficult tasksin the architectural acoustics field. This test method provides a means of objectively measuring therelevant acoustical characteristics of three major components of open-plan spaces, the ceiling system,furniture panels use
5、d as acoustical barriers, and wall finishes which attenuate reflected sound.Furniture panels may be tested for their capacity as an acoustical barrier and/or the degree to whichthey may reduce reflected sound.1. Scope1.1 This test method covers the measurement of the inter-zone attenuation for three
6、 components of open-plan spaces:1.1.1 Ceiling systems when used in conjunction withpartial-height space dividers. This arrangement is commonlyused in offices to achieve speech privacy between work zonesin the absence of full-height partitions. This test method isapplicable to any ceiling configurati
7、on, including, for example,a pattern of sound-reflective panels in an otherwise sound-absorptive ceiling. This test method generally requires use of afixed space divider height of 1.50 m 5 ft. In recognition oftrends toward alternate divider heights in open officeenvironments, measurements with an a
8、lternate divider heightmay be conducted in accordance with this standard.1.1.2 Furniture panels used as acoustical barriers in open-plan spaces to provide speech privacy or sound isolationbetween working positions.1.1.3 Vertical panels, including wall finishes such as sound-absorbent panels, and fur
9、niture panels or screens which mayreflect sound. It may not be applicable to such items as windowfinishes or furniture other than panels if these differ signifi-cantly from flat wall panels.1.1.4 The combination of results from the various compo-nents of an open-plan office is beyond the scope of th
10、isstandard.1.2 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-confo
11、rmancewith the standard.1.3 Unless otherwise qualified, all dimensions specified inthis test method shall be understood to have a tolerance of 66mm (614 in.) The values stated in SI units are to be regardedas the standard. The values given in parentheses are providedfor information only.1.4 This sta
12、ndard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1
13、ASTM Standards:2C423 Test Method for SoundAbsorption and SoundAbsorp-tion Coefficients by the Reverberation Room Method1This test method is under the jurisdiction ofASTM Committee E33 on Buildingand Environmental Acoustics and is the direct responsibility of SubcommitteeE33.02 on Speech Privacy.Curr
14、ent edition approved Sept. 1, 2014. Published January 2015. Originallyapproved in 1986. Last previous edition approved in 2007 as E1111 07. DOI:10.1520/E1111_E1111M-14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual
15、 Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1C634 Terminology Relating to Building and EnvironmentalAcousticsE795 Practices
16、for Mounting Test Specimens During SoundAbsorption TestsE1110 Classification for Determination of Articulation ClassE1179 Specification for Sound Sources Used for TestingOpen Office Components and SystemsE1374 Guide for Open Office Acoustics and ApplicableASTM Standards2.2 ANSI Standards:S1.4 Specif
17、ication for Sound Level Meters3S1.6 Preferred Frequencies and Band Numbers for Acousti-cal Measurements3S1.11 Specification for Octave Band and Fractional-Octave-Band Analog and Digital Filters33. Terminology3.1 The following terms used in this test method havespecific meanings that are defined in T
18、erminology C634:3.1.1 acoustical barrier, ambient noise, diffraction, level,(sound) absorption coefficient, sound pressure levels, pinknoise, white noise.3.2 Definitions of Terms Defined in Other Standards notincluded in Terminology C634:3.2.1 The term source point is defined in SpecificationE1179.3
19、.3 Definitions of Terms Specific to This Standard:3.3.1 furniture panela furnishing that does not extend tothe ceiling, and that is used to subdivide an open-plan spaceand provide a degree of visual and acoustical privacy. Furniturepanels include interlocking systems furniture and freestandingscreen
20、s.3.3.2 nominal reference levelfor a one-third octave-band,the arithmetic mean of sound pressure levels measured atspecified positions relative to the source in a region free fromreflections.3.3.3 interzone attenuationat a specified position, for aone-third octave band, the difference between the no
21、minalreference level and the sound pressure level at the specifiedpoint.3.3.4 nominal interzone attenuationfor a one-thirdoctave-band, at a specified point, the arithmetic mean interzoneattenuation calculated using the interzone attenuation for thepoint in question and for two adjacent positions 0.3
22、0 m (1 ft)along the survey path.4. Summary of Test Method4.1 The test facility is essentially an expanse of floor andceiling in which all surfaces excluding the floor and testspecimen have negligible sound reflections. The facility maybe set up in a laboratory, in a mock-up of a proposed building,or
23、 in a completed building. The configuration of the room willdepend on the open-plan component being tested.4.1.1 For testing a ceiling system, a standard space divideris positioned with such dimensions and construction that soundgenerated on one side can reach a measuring point on the otherside only
24、 by way of diffraction over the top of the space dividerand by reflection from the ceiling. With the diffracted compo-nent fixed by the dimensions of the space divider and by theheight of the source and measurement position, the differencebetween the sound pressure levels measured on each side of th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME1111E1111M2014STANDARDTESTMETHODFORMEASURINGTHEINTERZONEATTENUATIONOFOPENOFFICECOMPONENTS 测量 办公

链接地址:http://www.mydoc123.com/p-527930.html