《ASTM E247-2001(2015)e1 5321 Standard Test Method for Determination of Silica in Manganese Ores Iron Ores and Related Materials by Gravimetry《用重量法测定锰矿石 铁矿石和相关原料中硅含量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E247-2001(2015)e1 5321 Standard Test Method for Determination of Silica in Manganese Ores Iron Ores and Related Materials by Gravimetry《用重量法测定锰矿石 铁矿石和相关原料中硅含量的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E247 01 (Reapproved 2015)1Standard Test Method forDetermination of Silica in Manganese Ores, Iron Ores, andRelated Materials by Gravimetry1This standard is issued under the fixed designation E247; the number immediately following the designation indicates the year oforiginal adoption or
2、, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEEditorially corrected 1.1 and Table 1 in November 2015.1. Scope1.1 This test method co
3、vers the determination of silica iniron ores, iron ore concentrates and agglomerates, and manga-nese ore in the range from 0.5 % to 15 %.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to a
4、ddress all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1193 Speci
5、fication for Reagent WaterE50 Practices for Apparatus, Reagents, and Safety Consid-erations for Chemical Analysis of Metals, Ores, andRelated MaterialsE135 Terminology Relating to Analytical Chemistry forMetals, Ores, and Related MaterialsE691 Practice for Conducting an Interlaboratory Study toDeter
6、mine the Precision of a Test MethodE877 Practice for Sampling and Sample Preparation of IronOres and Related Materials for Determination of Chemi-cal Composition and Physical PropertiesE882 Guide for Accountability and Quality Control in theChemical Analysis Laboratory3. Terminology3.1 DefinitionsFo
7、r definitions of terms used in this testmethod, refer to Terminology E135.4. Summary of Test Method4.1 The sample is fused with sodium peroxide in a zirco-nium crucible. The melt is leached with water and dissolved inHCl. Silica is separated by double dehydration with HClO4.The two precipitates are
8、combined, ignited, and weighed. Thesilica is volatilized by treatment with HF and H2SO4and theresidue weighed.5. Significance and Use5.1 This test method is intended to be used for compliancewith compositional specifications for silica content. It isassumed that all who use these procedures will be
9、trainedanalysts capable of performing common laboratory proceduresskillfully and safely. It is expected that work will be performedin a properly equipped laboratory and that proper wastedisposal procedures will be followed. Appropriate qualitycontrol practices must be followed such as those describe
10、d inGuide E882.6. Interferences6.1 This test method is written for iron and manganese orescontaining less than 0.25 % of fluorine. None of the elementsnormally found in iron ores or in manganese ores interfere withthis test method.7. Apparatus7.1 Zirconium Crucible (50-mL capacity).7.2 Platinum Filt
11、er Cone.8. Reagents and Materials8.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents conform to the specifications of the Committee onAnalytical Reagents of the American Chemical Society where1This test method is under
12、the jurisdiction of ASTM Committee E01 onAnalytical Chemistry for Metals, Ores, and Related Materials and is the directresponsibility of Subcommittee E01.02 on Ores, Concentrates, and Related Metal-lurgical Materials.Current edition approved Nov. 15, 2015. Published December 2015. Originallyapproved
13、 in 1964. Last previous edition approved in 2010 as E247 01 (2010).DOI: 10.1520/E0247-01R15E01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Documen
14、t Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1such specification are available.3Other grades may be used,provided it is first ascertained that the reagent is of sufficienthigh purity to permit its u
15、se without lessening the accuracy ofthe determination.8.2 Purity of WaterUnless otherwise indicated, refer-ences to water shall be understood to mean reagent water asdefined by Type II of Specification D1193.8.3 Hydrochloric Acid (sp gr 1.19)Concentrated HCl.8.4 Hydrochloric Acid (1 + 49)Mix 1 volum
16、e of concen-trated HCl (sp gr 1.19) with 49 volumes of water.8.5 Hydrofluoric Acid (48 %)Concentrated HF.8.6 Perchloric Acid (70 %)HClO4.8.7 Sodium Peroxide PowderNa2O2.8.8 Sulfuric Acid (1 + 1)Carefully pour one volume ofconcentrated H2SO4, sp gr 1.84, into one volume of water.9. Hazards9.1 For pre
17、cautions to be observed in this method, refer toPractices E50.10. Sampling and Sample Preparation10.1 SamplingThe gross sample shall be collected andprepared in accordance with Practice E877.10.2 Sample PreparationThe laboratory sample shall bepulverized to pass a No. 100 (150-m) sieve.NOTE 1To faci
18、litate decomposition, some ores, such as specularhematite, require grinding to pass a No. 200 (75-m) sieve.10.3 Sample WeightWeigh approximately (within6 25 mg) an amount of test sample specified as following:Content of Silica, % Weight of Test Sample, gLess than 2 1.02 and over 0.511. Procedure11.1
19、 Transfer the test sample to a small, dry weighing bottleand place in a drying oven. Dry iron ore samples at 110 C andmanganese ore samples at 120 C for 1 h. Cap the bottle andcool to room temperature in a desiccator. Momentarily releasethe cap to equalize pressure and weigh the capped bottle to the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME24720012015E15321STANDARDTESTMETHODFORDETERMINATIONOFSILICAINMANGANESEORESIRONORESANDRELATEDMATERIALSBYGRAVIMETRY

链接地址:http://www.mydoc123.com/p-527212.html