ASTM D8010-2015 4225 Standard Practice for Determination of Water Soluble Alkali Content in Coal《用于测定煤炭中水溶性碱含量的标准实施规程》.pdf
《ASTM D8010-2015 4225 Standard Practice for Determination of Water Soluble Alkali Content in Coal《用于测定煤炭中水溶性碱含量的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D8010-2015 4225 Standard Practice for Determination of Water Soluble Alkali Content in Coal《用于测定煤炭中水溶性碱含量的标准实施规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D8010 15Standard Practice forDetermination of Water Soluble Alkali Content in Coal1This standard is issued under the fixed designation D8010; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A
2、 number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice describes a procedure for the determina-tion of water soluble sodium oxide (Na2O) and potassiumoxide (K2O) in the analys
3、is of coal samples prepared inaccordance with Practice D2013.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This practice is derived in part from the ASME proce-dure water soluble alkalis.21.4 This standard does not pur
4、port to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3D1
5、21 Terminology of Coal and CokeD1193 Specification for Reagent WaterD2013 Practice for Preparing Coal Samples for AnalysisD3173 Test Method for Moisture in the Analysis Sample ofCoal and CokeD3302 Test Method for Total Moisture in CoalD7582 Test Methods for Proximate Analysis of Coal andCoke by Macr
6、o Thermogravimetric AnalysisE832 Specification for Laboratory Filter Papers3. Terminology3.1 For definitions of terms used in this practice, refer toTerminology D121.4. Summary of Practice4.1 Sodium and potassium salts are leached from the sampleduring a lengthy digestion with water and a wetting ag
7、ent. Theconcentrations of sodium and potassium are measured in thefiltered liquid by an appropriate spectrometric technique for theelements sodium and potassium.5. Significance and Use5.1 Results obtained from the practice are used to serve anumber of interests, including the indication of possible
8、boilertube fouling and possible furnace corrosion problems.6. Interferences6.1 Several types of interference effects may contribute toinaccuracies in the determination of sodium and potassium.Follow the manufacturers operating guide to develop andapply correction factors to compensate for the interf
9、erences.7. Apparatus7.1 Analytical balance, with sensitivity of 0.1 mg.7.2 Digestion Apparatus7.2.1 Stirring Hotplate and Bars, with operating tempera-ture up to 200 C.7.2.1.1 Erlenmeyer flask with cover, 250 mL.7.2.1.2 Refluxing column (optional).7.2.2 Hot Block Digestion7.2.2.1 Polycarbonate Bottl
10、es, 250 mL capacity with anO-ring seal and screw cap, capable of withstanding tempera-tures up to 130 C, the pressure that is developed during thedigestion, and resistant to oxidation. Other types of bottles orvials may be used provided they are capable of withstandingthe temperatures and pressures
11、developed during the digestion.7.3 Filtering Apparatus7.3.1 Filter Paper or 0.45 micron filter. The paper used mustbe ash-free, quantitative Type II filter paper, as described inSpecification E832.7.3.2 Filter (gravity or vacuum).7.3.3 Volumetric flask, 250 mL.7.4 SpectrometerBecause of the differen
12、ces between vari-ous makes and models of satisfactory instruments, no detailedoperating instructions can be provided. Instead, follow theinstructions provided by the manufacturer of the particular1This test method is under the jurisdiction of ASTM Committee D05 on Coaland Coke and is the direct resp
13、onsibility of Subcommittee D05.21 on Methods ofAnalysis.Current edition approved Nov. 1, 2015. Published December 2015. DOI:10.1520/D8010-15.2“Coal Fouling and Slagging Parameters.” ASME H-86. Editor E.C.Winegartner, 1974.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontac
14、t ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1instrument. Sensitivity,
15、instrumental detection limit, precision,linear dynamic range, and interference effects must be inves-tigated and established for each individual analyte line on thatparticular instrument. All measurements must be within theinstruments linear range in which correction factors are valid.It is the resp
16、onsibility of the analyst to verify that theinstrument configuration and operating conditions used satisfythe analytical requirements of this method and to maintainquality control data confirming instrument performance andanalytical results.8. Reagents and Materials8.1 Purity of ReagentsUse reagent
17、grade chemicals in alltests that conform to the specifications of the Committee onAnalytical Reagents of theAmerican Chemical Society,4wheresuch specifications are available.8.2 Purity of WaterUnless otherwise indicated, referencesto water are understood to mean Type II reagent water asdefined in Sp
18、ecification D1193.8.3 Wetting AgentApproximately 1 to 5 mL of isopropylalcohol, methanol or ethanol may be added to the sample.8.4 Standard Stock SolutionsStock solutions of1000 mg L for each element are needed for preparation ofdilute standards in the range from 0.1 to 100 mg/L. Preparestandard sto
19、ck solutions from 99.999 % (mass/mass) puritymetals or salts. Alternatively, use commercially available stocksolutions specifically prepared for the correct spectroscopymethod. Dilute standard solutions are also used initially andperiodically to verify the baseline of the calibration has notchanged
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD801020154225STANDARDPRACTICEFORDETERMINATIONOFWATERSOLUBLEALKALICONTENTINCOAL 用于 测定 煤炭 水溶性 含量 标准

链接地址:http://www.mydoc123.com/p-526632.html