ASTM D7558-2009(2014) 7874 Standard Test Method for Colorimetric Spectrophotometric Procedure to Quantify Extractable Chemical Dialkyldithiocarbamate Thiuram and Mercaptobenzothiaz.pdf
《ASTM D7558-2009(2014) 7874 Standard Test Method for Colorimetric Spectrophotometric Procedure to Quantify Extractable Chemical Dialkyldithiocarbamate Thiuram and Mercaptobenzothiaz.pdf》由会员分享,可在线阅读,更多相关《ASTM D7558-2009(2014) 7874 Standard Test Method for Colorimetric Spectrophotometric Procedure to Quantify Extractable Chemical Dialkyldithiocarbamate Thiuram and Mercaptobenzothiaz.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7558 09 (Reapproved 2014)Standard Test Method forColorimetric/Spectrophotometric Procedure to QuantifyExtractable Chemical Dialkyldithiocarbamate, Thiuram, andMercaptobenzothiazole Accelerators in Natural RubberLatex and Nitrile Gloves1This standard is issued under the fixed designatio
2、n D7558; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or rea
3、pproval.1. Scope1.1 This test method is designed to quantify the amount oftotal extractable accelerators in natural rubber latex (NRL) andnitrile gloves. Three common classes of rubber accelerators,the mercaptobenzothiazole (MBT), thiuram, and thiocarbamatetype compounds can be detected and quantifi
4、ed by this method.If the specific rubber accelerator(s) present in the glovematerial is not known, quantification is based on zinc dibutyl-dithiocarbamate (ZDBC) equivalents. This method will notdetect all potential rubber accelerators, including mercaptoben-zothiazole disulfide, dimorpholine, thiou
5、reas and diphenyldiamine.1.2 For the purpose of this test method, the range ofchemical accelerator measurement is based on the limit ofdetection (LOD) established in the performing laboratory.1.3 This test method should be performed by experiencedanalysts or under the supervision of those experience
6、d in theuse of spectroscopy and working with organic solvents.1.4 This test method has not been validated for measure-ment of long chain dithiocarbamates or accelerators from otherrubber products, such as lubricated condoms (1).2Althoughthis assay has been reported in the literature for the evaluati
7、onof accelerator levels in condoms, further validation for accel-erator measurement from other rubber products is required bythe testing laboratory prior to use.1.5 This test method is not designed to evaluate the potentialof rubber materials to induce or elicit Type IV skin sensitiza-tion reactions
8、 (for Type IV skin sensitization reactions see TestMethod D6355). Total extractable accelerator content does notreflect bioavailablity of individual accelerators that are de-tected and measured by this method. This test method shouldbe used to test and measure the total residual chemicalaccelerator
9、level in NRL and nitrile gloves under controlledlaboratory conditions, and should not be used to describe,appraise, or assess the hazard or risk of these materials orproducts under actual in-use conditions.1.6 The values stated in SI units are to be regarded asstandard. No other units of measurement
10、 are included in thisstandard.1.7 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitation
11、s prior to use.2. Referenced Documents2.1 ASTM Standards:3D3577 Specification for Rubber Surgical GlovesD3578 Specification for Rubber Examination GlovesD4483 Practice for Evaluating Precision for Test MethodStandards in the Rubber and Carbon Black ManufacturingIndustriesD6355 Test Method for Human
12、Repeat Insult Patch Testingof Medical Gloves3. Terminology3.1 Total thiol vulcanization accelerator includes MBT, zincdithiocarbamates (ZDTCs) and thiurams.3.2 Definitions:3.2.1 limit of detection (LOD), nthe lowest acceleratorconcentration that can be measured and be statistically differentfrom the
13、 blank.3.2.1.1 DiscussionThe LOD is expressed as 3.3 stan-dard error of the y-intercept of the standard plot regression linedivided by the slope of the calibration line.1This test method is under the jurisdiction of ASTM Committee D11 on Rubberand is the direct responsibility of Subcommittee D11.40
14、on Consumer RubberProducts.Current edition approved Nov. 1, 2014. Published December 2014. Originallyapproved in 2009. Last previous edition approved in 2009 as D7558 09. DOI:10.1520/D7558-09R14.2The boldface numbers in parentheses refer to a list of references at the end ofthis standard.3For refere
15、nced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West C
16、onshohocken, PA 19428-2959. United States13.2.2 limit of quantitation (LOQ), nthe lowest acceleratorconcentration that can be measured to produce quantitativelymeaningful results with acceptable precision and accuracy.3.2.2.1 DiscussionThe LOQ is expressed as 10 standarderror of the y-intercept of t
17、he standard plot regression linedivided by the slope of the calibration line.3.2.3 linear range, narea of a graph of absorbance versusconcentration that approximates a straight line.3.2.4 spectrophotometric measurement, n the unit of mea-sure of the instrument that is proportional to absorbance.3.2.
18、5 standard solution, nthe standard analyte to whichthe test (unknown) sample being measured is compared.4. Summary of Test Method4.1 The rubber material is cut into small pieces andapproximately1gisplaced into the extraction vessel.Acetoni-trile is added to give a final volume/weight of 10 mLacetoni
19、trile per gram of rubber. The extraction vessel issecurely capped, placed onto a rotator and extracted at approxi-mately 200 rpm for a minimum of 2 h at room temperature(25 6 5C). The acetonitrile extract is recovered and centri-fuged in a sealed centrifuge tube at 500 g for 20 min at roomtemperatur
20、e to remove any residual particulate matter. Theacetonitrile extract supernatant fluid is transferred to a cleancontainer and capped. Zinc dibutyldithiocarbamate (ZDBC)standards at 500 to 31.25 g/mL in acetonitrile and a blank areprepared. Cobalt chloride (10 L, 420 mmol/L) aqueoussolution is added
21、to 1 mL aliquots of each sample extract andstandard. Each individual solution is thoroughly mixed andthen incubated for 120 min at 50 6 5C. The extracts andstandards are cooled to room temperature for approximately 15min after the 50C incubation. A100 L aliquot of each isdiluted with 1.9 mL of aceto
22、nitrile. All are mixed thoroughlyand absorbance of each sample, blank and standard is mea-sured at 320 nm on a UV spectrophotometer. Concentration ofresidual accelerator is obtained by extrapolation from thestandard plot. Depending upon the number of samples tested,this test method takes about5htoco
23、mplete.5. Significance and Use5.1 Dialkyldithiocarbamates (DTCs), benzothiazoles, andthiurams are often used as vulcanization accelerators in NRLproducts. Zinc DTC accelerators are added either directly orare formed in situ during the vulcanization process via reactionbetween a thiuram(s) and zinc o
24、xide. DTCs, benzothiazoles,and thiurams have been detected in leachates from medicaldevices made of rubber such as gloves. Studies have shownthese chemicals can cause allergic contact dermatitis. A simpleselective method to monitor rubber accelerator levels in rubberextracts would be useful for qual
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD7558200920147874STANDARDTESTMETHODFORCOLORIMETRICSPECTROPHOTOMETRICPROCEDURETOQUANTIFYEXTRACTABLECHEMICALDIALKYLDITHIOCARBAMATETHIURAMANDMERCAPTOBENZOTHIAZPDF

链接地址:http://www.mydoc123.com/p-525802.html