ASTM D7339-2007 Standard Test Method for Determination of Volatile Organic Compounds Emitted from Carpet using a Specific Sorbent Tube and Thermal Desorption Gas Chromatography《用特.pdf
《ASTM D7339-2007 Standard Test Method for Determination of Volatile Organic Compounds Emitted from Carpet using a Specific Sorbent Tube and Thermal Desorption Gas Chromatography《用特.pdf》由会员分享,可在线阅读,更多相关《ASTM D7339-2007 Standard Test Method for Determination of Volatile Organic Compounds Emitted from Carpet using a Specific Sorbent Tube and Thermal Desorption Gas Chromatography《用特.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 7339 07Standard Test Method forDetermination of Volatile Organic Compounds Emitted fromCarpet using a Specific Sorbent Tube and ThermalDesorption / Gas Chromatography1This standard is issued under the fixed designation D 7339; the number immediately following the designation indicates
2、 the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method describes an analytical proce
3、dure foridentifying and quantifying the masses of individual volatileorganic compounds (individual VOCs or IVOCs) that areemitted into a flow of air from carpet specimens and collectedon sorbent sampling tubes during emissions testing.1.2 This test method will be used in conjunction with astandard p
4、ractice for sampling and preparing carpet specimensfor emissions testing. If a specific chamber practice is notavailable for the carpet specimens, this standard test methodshould be used in conjunction with approved standard practicesfor emissions testing and sample preparation.1.3 When used in conj
5、unction with standard practices forcarpet specimen preparation and collection of vapor-phaseemissions , this test method will provide a standardized meansof determining the levels of IVOC in the exhaust stream of theemissions test chamber/cell. If this test method is used with areliable practice for
6、 emissions testing, these IVOC levels canbe used to determine the emission rate from a unit quantity(usually surface area) of the sample material under test.1.4 VOCs in the exhaust stream of an emissions test deviceare collected on thermal desorption tubes packed with aspecific combination of sorben
7、ts using active (pumped) sam-pling. (See Practice D 6196 for a more general description ofvapor collection using pumped sampling onto sorbent tubes).The samples are analyzed by thermal desorption (TD) with gaschromatography and mass spectrometry detection (GC/MS)and/or flame ionization detection (FI
8、D) depending upon therequirements of the specific materials emissions testing/certification protocol.1.5 This test method can be used for the measurement ofmost GC-compatible organic vapors ranging from the approxi-mate volatility from n-hexane to n-hexadecane (that is, com-pounds with vapor pressur
9、es ranging from 16 kPa to 4 3 10-4kPa at 25C). Properties other than a compounds vaporpressure such as affinity for the sorbent may need to be takeninto account. Compounds with vapor pressures outside thisrange may or may not be quantifiable by this method. How-ever, qualitative data concerning the
10、identity of a compound(s),outside the stated volatility range for quantitation, may still beuseful to the user. The method can be applied to analytes overa wide concentration rangetypically 1 g/m3to 1 mg/m3concentration of vapor in the exhaust air from the emission cellor chamber.1.6 This test metho
11、d is not capable of quantifying allcompounds which are emitted from carpets. See the appropri-ate test practices/methods for determining other compoundsthat are not amenable to analysis by gas chromatography (thatis, Test Method D 5197 for the determination of aldehydes).1.7 This standard does not p
12、urport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2
13、D 1356 Terminology Relating to Sampling and Analysis ofAtmospheresD 3686 Practice for Sampling Atmospheres to Collect Or-ganic Compound Vapors (Activated Charcoal Tube Ad-sorption Method)D5116 Guide for Small-Scale Environmental Chamber De-terminations of Organic Emissions From Indoor Materials/Prod
14、uctsD 5197 Test Method for Determination of Formaldehydeand Other Carbonyl Compounds in Air (Active SamplerMethodology)D 5337 Practice for Flow Rate Calibration of PersonalSampling PumpsD 6196 Practice for Selection of Sorbents, Sampling, andThermal Desorption Analysis Procedures for Volatile Or-gan
15、ic Compounds in AirD 6670 Practice for Full-Scale Chamber Determination of1This test method is under the jurisdiction of ASTM Committee D22 on AirQuality and is the direct responsibility of Subcommittee D22.05 on Indoor Air.Current edition approved April 1, 2007. Published May 2007.2For referenced A
16、STM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Consho
17、hocken, PA 19428-2959, United States.Volatile Organic Emissions from Indoor Materials/ProductsD 7143 Practice for Emission Cells for the Determination ofVolatile Organic Emissions from Indoor Materials/ProductsE 355 Practice for Gas Chromatography Terms and Rela-tionships2.2 ISO Standards:3EN ISO 16
18、000-6 Determination of volatile organic com-pounds in indoor and test chamber air by active samplingon Tenax TA sorbent, thermal desorption and gas chroma-tography using MS/FIDEN ISO 16000-9 Indoor AirPart 9: Determination of theemission of volatile organic compounds from buildingproducts and furnis
19、hingsEmission test chamber methodEN ISO 16000-10 Indoor AirPart 10: Determination ofthe emission of volatile organic compounds from buildingproducts and furnishingsEmission test cell methodEN ISO 16000-11 Indoor AirPart 11: Determination ofthe emission of volatile organic compounds from buildingprod
20、ucts and furnishingsSampling, storage of samplesand preparation of test specimens2.3 US EPA Methods:4TO-15 Determination of Volatile Organic Compounds(VOCs) in Air Collected in Specially-Prepared Canistersand Analyzed by Gas Chromatography/Mass Spectrom-etry (GC/MS)TO-17 Determination of Volatile Or
21、ganic Compounds inAmbient Air Using Active Sampling onto Sorbent Tubes3. Terminology3.1 DefinitionsRefer to Terminology D 1356 and PracticeE 355 for definitions of terms used in this test method.4. Summary of Test Method4.1 A sample of the VOCs emitted from a carpet specimenis collected following th
22、e preparation and collection guidelinesprovided in the appropriate chamber/emission cell practices/guides. See, for example Guide D5116 (small chamber),Practice D 6670 (full-scale chamber), Practice D 7143 (emis-sion cells), EN ISO 16000-9 (small chambers),EN ISO 16000-10 (emission cells), ENV 13419
23、-1 (smallchambers), ENV 13419-2 (emission cells), andEN ISO 16000-11 16000-11 (sample preparation).4.2 Organic vapors in the exhaust stream of an emission testchamber or cell are pumped onto standard thermal desorptiontubes (see Practice D 6196) containing either 200 mg of apolyphenylene oxide resin
24、-based (PPOR-B) sorbent with ashort bed (1-2 mm) of quartz wool, a glass frit, or stainless steelscreen at each end of the 200 mg of PPOR-B sorbent. Thepump flow rate and sampling time must be controlled (seePractice D 6196). The sorbent tubes are then thermally des-orbed, in a reverse flow of carri
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD73392007STANDARDTESTMETHODFORDETERMINATIONOFVOLATILEORGANICCOMPOUNDSEMITTEDFROMCARPETUSINGASPECIFICSORBENTTUBEANDTHERMALDESORPTIONGASCHROMATOGRAPHY

链接地址:http://www.mydoc123.com/p-525208.html