ASTM D7338-2010 3125 Standard Guide for Assessment Of Fungal Growth in Buildings《建筑物中霉菌生长评估指南》.pdf
《ASTM D7338-2010 3125 Standard Guide for Assessment Of Fungal Growth in Buildings《建筑物中霉菌生长评估指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7338-2010 3125 Standard Guide for Assessment Of Fungal Growth in Buildings《建筑物中霉菌生长评估指南》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7338 10Standard Guide forAssessment Of Fungal Growth in Buildings1This standard is issued under the fixed designation D7338; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in paren
2、theses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide provides a compendium of information and amenu of options for assessment of fungal growth in buildings,but does not recommend a specific co
3、urse of action. Due to thewide variety of fungal problems affecting buildings and theiroccupants, and the wide variety of buildings, it is not possibleto describe a set of uniform steps that will always be performedduring an assessment (that is, a standard practice); therefore theuser of this guide
4、must decide which steps are appropriate fora given situation or building.1.2 This guide is specific to fungal growth, which is onlyone potential problem in a building environment. It may be partof, but is not intended to take the place of, a comprehensiveindoor air quality investigation.1.3 This gui
5、de describes minimum steps and procedures forcollecting background information on a building in question,procedures for evaluating the potential for moisture infiltrationor collection, procedures for inspection for suspect fungalgrowth, and procedures beyond the scope of a basic survey thatmay be us
6、eful for specific problems.1.4 Assessments for fungal growth may be useful whereverfungal growth is suspected, excess moisture has been presentor when there are concerns regarding potential fungal growth.1.5 Periodic fungal assessment in buildings may be acomponent of preventative maintenance progra
7、ms.1.6 This guide is applicable to buildings including residen-tial (for example, single or multi-family), institutional (forexample, schools, hospitals), government, public assembly,commercial (for example, office, retail), and industrial facili-ties.1.7 Recommendations for developing a sampling st
8、rategy ormethods for the collection and analysis of fungal samples arebeyond the scope of this guide. For recommendations fordeveloping a sampling strategy, see Ref (27)2, Chapter 10.1.8 Recommendations for remediation of fungal growth arebeyond the scope of this guide.1.9 This guide is not intended
9、 to supersede any governmentregulations governing the assessment of fungal growth inbuildings.1.10 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health pr
10、actices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3C755 Practice for Selection of Water Vapor Retarders forThermal InsulationC1699 Test Method for Moisture Retention Curves ofPorous Building Materials Using Pressure PlatesD653 T
11、erminology Relating to Soil, Rock, and ContainedFluidsD4442 Test Methods for Direct Moisture Content Measure-ment of Wood and Wood-Base MaterialsE331 Test Method for Water Penetration of Exterior Win-dows, Skylights, Doors, and Curtain Walls by UniformStatic Air Pressure DifferenceE547 Test Method f
12、or Water Penetration of Exterior Win-dows, Skylights, Doors, and Curtain Walls by Cyclic StaticAir Pressure DifferenceE631 Terminology of Building ConstructionsE1105 Test Method for Field Determination of Water Pen-etration of Installed Exterior Windows, Skylights, Doors,and Curtain Walls, by Unifor
13、m or Cyclic Static AirPressure DifferenceE1186 Practices for Air Leakage Site Detection in BuildingEnvelopes and Air Barrier SystemsE1356 Test Method for Assignment of the Glass TransitionTemperatures by Differential Scanning CalorimetryE2128 Guide for Evaluating Water Leakage of BuildingWallsE2270
14、Practice for Periodic Inspection of Building Facadesfor Unsafe Conditions1This guide is under the jurisdiction of ASTM Committee D22 on Air Qualityand is the direct responsibility of Subcommittee D22.08 on Sampling and Analysisof Mold.Current edition approved Dec. 1, 2010. Published January 2011. DO
15、I:10.1520/D7338-10.2The boldface numbers in parentheses refer to a list of references at the end ofthis standard.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the
16、 standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.2.2 Non-ASTM Standards:ANSI/GEI Standard MMS1001 Mold and Moisture Man-agement Standard for New Construction3. Terminology3.1 Definit
17、ions:3.1.1 building envelope, nthe outer elements of a build-ing, both above and below ground, which divide the externalfrom the internal environments. Commonly included are exte-rior walls, windows, doors, roofs and subfloors. E6313.1.2 bulk sample, npiece or quantity of bulk material thathas been
18、selected by some sampling process. D6533.1.3 capillary action, n(or capillary migration), of water,movement of water induced by the force of molecular attrac-tion (surface tension) between the water and the material itcontacts. E6313.1.4 condensation, nthe process of converting a materialin the gase
19、ous phase to a liquid by decreasing temperature orby increasing pressure, or both. E13563.1.5 exposure, ncontact with a chemical, biological,physical, or other agent over a specified time period. E13563.1.6 moisture content, nmass of water retained in thespecimen divided by the dry mass of the speci
20、men. C16993.1.7 soot, nagglomerations of particles of carbon im-pregnated with tar, formed in the incomplete combustion ofcarbonaceous material. E13563.1.8 vapor retarder, na material or system that ad-equately impedes the transmission of water vapor underspecified conditions. E6313.2 Definitions of
21、 Terms Specific to This Standard:3.2.1 boroscope, ndevice for internal inspection of diffi-cult access locations such as wall cavities. Its long narrow tubecontains a telescope system with a number of relay lenses.Light is provided via the optical path or fiber bundles.3.2.2 effloresce, vprocess by
22、which water leaches solublesalts out of concrete or mortar for surface deposit. Alsoefflorescence, n, the name for these deposits.3.2.3 enzyme activity, nmeasure of the quantity of activeenzyme present. Enzyme activity is essential to metabolism.Specifically, beta-N-acetylhexosaminidase (NAHA) is an
23、 en-zyme present in all filamentous fungi, the measurement ofwhich has been shown to be directly proportional to the amountof fungal biomass (see (18, 28).3.2.4 fungus, n(pl. fungi) a kingdom of organisms includ-ing molds, mildews, mushrooms, yeasts and many parasites.These are important decomposers
24、 in ecosystems. Fungi aretypically multi-cellular fungi with filamentous vegetative hy-phae.3.2.5 fungal spore, ngeneral term for a reproductivestructure in fungi. The spore is the structure that may be usedfor dissemination and reproduction, and may be resistant toadverse environmental conditions.3
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 1人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD733820103125STANDARDGUIDEFORASSESSMENTOFFUNGALGROWTHINBUILDINGS 建筑物 霉菌 生长 评估 指南 PDF

链接地址:http://www.mydoc123.com/p-525206.html