《ASTM D6855-2012 red 0000 Standard Test Method for Determination of Turbidity Below 5 NTU in Static Mode《静态模式下测定混浊度小于5 NTU的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6855-2012 red 0000 Standard Test Method for Determination of Turbidity Below 5 NTU in Static Mode《静态模式下测定混浊度小于5 NTU的标准试验方法》.pdf(19页珍藏版)》请在麦多课文档分享上搜索。
1、Designation:D685510D685512 Standard Test Method for Determination of Turbidity Below 5 NTU in Static Mode 1 This standard is issued under the xed designation D6855; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last
2、revision.Anumber in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval. 1. Scope* 1.1 This test method covers the static determination of turbidity in water (see 4.1). 1.2 This test method is applicable to th
3、e measurement of turbidities under 5.0 nephelometric turbidity units (NTU). 1.3 This test method was tested on municipal drinking water, ultra-pure water and low turbidity samples. It is the users responsibility to ensure the validity of this test method for waters of untested matrices. 1.4 This tes
4、t method uses calibration standards are dened in NTU values, but other assigned turbidity units are assumed to be equivalent. 1.5 This test method assigns traceable reporting units to the type of respective technology that was used to perform the measurement.Unitsarenumericallyequivalentwithrespectt
5、othecalibrationstandard.Forexample,a1.0NTUformazinstandard is also equal to a 1.0 FNU standard, a 1.0 FNRU standard and so forth. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establ
6、ish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Refer to the MSDSs for all chemicals used in this procedure. 2. Referenced Documents 2.1 ASTM Standards: 2 D1129Terminology Relating to Water D1192Guide for Equipment for Sampling Wate
7、r and Steam in Closed Conduits (Withdrawn 2003) 3 D1193Specication for Reagent Water D2777Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water D3370Practices for Sampling Water from Closed Conduits D5847Practice for Writing Quality Control Specication
8、s for Standard Test Methods for Water Analysis E691Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method 2.2 Other Referenced Standards: USEPA Method 180.1Methods for Chemical Analysis of Water and Wastes, Turbidity 4 ISO 7027(The International Organization for
9、 Standardization) Water Qualityfor the Determination of Turbidity 5 3. Terminology 3.1 DenitionsFor denitions of terms used in this method refer to Terminology D1129. 3.2 Denitions: 3.2.1 calibration turbidity standardstandard, naA turbidity standard that is traceable and equivalent to the reference
10、 turbidity standard to within statistical errors, including errors; calibration turbidity standards include commercially prepared 4000 NTU Formazin, stabilized formazin (see 9.2.3), and styrenedivinylbenzene (SDVB) (see 9.2.4). These standards may be used to calibrate the instrument. 1 This test met
11、hod is under the jurisdiction ofASTM Committee D19 on Water and is the direct responsibility of Subcommittee D19.07 on Sediments, Geomorphology, and Open-Channel Flow. Current edition approved June 15, 2010June 1, 2012. Published August 2010June 2012. Originally approved in 2003. Last previous editi
12、on approved in 20032010 as D685503.D685510. DOI: 10.1520/D6855-10.10.1520/D6855-12. 2 ForreferencedASTMstandards,visittheASTMwebsite,www.astm.org,orcontactASTMCustomerServiceatserviceastm.org.ForAnnualBookofASTMStandards volume information, refer to the standards Document Summary page on the ASTM we
13、bsite. 3 The last approved version of this historical standard is referenced on www.astm.org. 4 Available from United States Environmental Protection Association (EPA), Ariel Rios Bldg., 1200 Pennsylvania Ave., NW, Washington, DC 20460. 5 Available from American National Standards Institute (ANSI),
14、25 W. 43rd St., 4th Floor, New York, NY 10036. This document is not anASTM standard and is intended only to provide the user of anASTM standard an indication of what changes have been made to the previous version. Because it may not be technically possible to adequately depict all changes accurately
15、,ASTM recommends that users consult prior editions as appropriate. In all cases only the current version of the standard as published by ASTM is to be considered the official document. *ASummary of Changes section appears at the end of this standard Copyright ASTM International, 100 Barr Harbor Driv
16、e, PO Box C700, West Conshohocken, PA 19428-2959. United States 13.2.1.1 Discussion these standards may be used to calibrate the instrument. NOTE 1Calibration standards may be instrument specic. 3.2.2 calibration verication standardsstandards, ndenedDenedstandardsusedtoverifytheaccuracyofacalibratio
17、nin themeasurementrangeofinterest.Thesestandardsmaynotbeusedtoperformcalibrations,onlycalibrationverications.Included standards are opto-mechanical light scatter devices, gel-like standards, or any other type of stable liquid standard. 3.2.2.1 Discussion these standards may not be used to perform ca
18、librations, only calibration verications. Included standards are opto-mechanical light scatter devices, gel-like standards, or any other type of stable liquid standard. NOTE 2Calibration verication standards may be instrument specic. 3.2.3 nephelometricturbiditymeasurementmeasurement,ntheThemeasurem
19、entoflightscatterfromasampleinadirection that is at 90 with respect to the centerline of the incident light path. Units are NTU (Nephelometric Turbidity Units); when ISO 7027 technology is employed units are in FNU (Formazin Nephelometric Units). 3.2.3.1 Discussion units are NTU (Nephelometric Turbi
20、dity Units); when ISO 7027 technology is employed units are in FNU (Formazin Nephelometric Units). 3.2.4 ratio turbidity measurementmeasurement, ntheThe measurement derived through the use of a nephelometric detector that serves as the primary detector and one or more other detectors used to compens
21、ate for variation in incident light uctuation, stray light, instrument noise, or sample color. 3.2.5 reference turbidity standardstandard, naAstandard that is synthesized reproducibly from traceable raw materials by askilledanalyst.Allotherstandardsaretracedbacktothisstandard.Thereferencestandardfor
22、turbidityisformazin(seetheuser. 9.2.2). 3.2.5.1 Discussion all other standards are traced back to this standard. The reference standard for turbidity is formazin (see 9.2.2). 3.2.6 seasoningseasoning, vtheThe process of conditioning laboratory glassware labware with the standard to be diluted to a l
23、ower value. The process reduces contamination and dilution errors. See Appendix X2 for the suggested procedure. 3.2.6.1 Discussion the process reduces contamination and dilution errors. See Appendix X2 for the suggested procedure. 3.2.7 stray lightlight, nallAll light reaching the detector other tha
24、n that contributed by the sample. For example: ambient light leakage, internal reections and divergent light in optical systems. 3.2.7.1 Discussion for example: ambient light leakage, internal reections and divergent light in optical systems. 3.2.8 turbidimeterturbidimeter, nanAn instrument that mea
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD68552012RED0000STANDARDTESTMETHODFORDETERMINATIONOFTURBIDITYBELOW5NTUINSTATICMODE 静态 模式 测定 混浊 小于

链接地址:http://www.mydoc123.com/p-523783.html