ASTM D6854-2012a red 7500 Standard Test Method for Silica-Oil Absorption Number《硅石吸油值的标准试验方法》.pdf
《ASTM D6854-2012a red 7500 Standard Test Method for Silica-Oil Absorption Number《硅石吸油值的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6854-2012a red 7500 Standard Test Method for Silica-Oil Absorption Number《硅石吸油值的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6854 12D6854 12aStandard Test Method forSilicaSilica-Oiln-Dibutyl Phthalate Absorption Number1This standard is issued under the fixed designation D6854; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、 revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the n-dibutyl phthalate (DBP) absorption number of silica.1.2 The values stat
3、ed in SI units are to be regarded as the standard. The values given in parentheses are for information only.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety
4、and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1799 Practice for Carbon BlackSampling Packaged ShipmentsD1900 Practice for Carbon BlackSampling Bulk ShipmentsD2414 Test Method for Carbon BlackOil Absorption Numbe
5、r (OAN)E177 Practice for Use of the Terms Precision and Bias in ASTM Test MethodsE691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method3. Summary of Test Method3.1 In this test method, DBP is added by means of a constant-rate buret to a sample of silica in
6、the mixer chamber of anabsorptometer. As the sample absorbs the DBP, the mixture changes from a free-flowing state to one of a semiplasticagglomeration, with an accompanying increase in viscosity. This increased viscosity is transmitted to the torque-sensing systemof the absorptometer. The test is s
7、topped when a predetermined torque level has been reached. Preferably the torque versus volumeof DBP is recorded by a penwriter or by a data acquisition system allowing a reliable determination of the endpoint. The volumeof DBP per unit mass of silica is the DBP absorption number.4. Significance and
8、 Use4.1 The DBP absorption number of a silica is related to the processing and vulcanizate properties of rubber compoundscontaining the silica.5. Apparatus35.1 Balance, analytical, with 0.001-g sensitivity.5.2 Sieve, 500 m (U.S. standard No. 35), having a 200-mm (8 in.) diameter and 25 mm (1 in.) he
9、ight.5.3 Bottom Receiver Pan.5.4 Oven, gravity-convection type, capable of temperature regulation within 61C at 125C and temperature uniformity within65C.5.5 Spatula, rubber, 100-mm.1 This test method is under the jurisdiction of ASTM Committee D11 on Rubber and is the direct responsibility of Subco
10、mmittee D11.20 on Compounding Materials andProcedures.Current edition approved Jan. 1, 2012Dec. 1, 2012. Published February 2012January 2013. Originally approved in 2003. Last previous edition approved in 20082012 asD6854 03 (2008).D6854 12. DOI: 10.1520/D6854-12.10.1520/D6854-12A.2 For referencedAS
11、TM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 All apparatus is to be operated and maintained in accordance with the manufac
12、turers directions for optimum performance.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, AS
13、TM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.6 Ab
14、sorptometer,4equipped with a constant-rate buret that delivers 4 6 0.024 cm3/min.5.7 Desiccator, with silica gel as desiccant.6. Reagents and Standards6.1 n-Dibutyl Phthalate,5having a density of 1.042 to 1.047 mg/m3 (g/cm3) at 25C.6.2 Silica, commercial grade with a nitrogen surface area of 175 6 1
15、0 m2/g.7. Sampling7.1 Samples shall be taken in accordance with Practices D1799 and D1900.8. Calibration8.1 Absorptometer6 The absorptometer is composed of components that influence calibration: the dynamometer torque springor the load cell, the torque-limit or the indicator set point, the oil dampe
16、r (absorptometers Type E and Type H are equipped withelectronic damping), and the mixer-measuring head.7 It is necessary that each of the components be in good condition or properadjustment to achieve acceptable calibration.NOTE 1Stainless steel mixing chambers8 have been found satisfactory for this
17、 test when they are manufactured to a roughness average (Ra) of 2.56 0.4 m (100 6 15 in.) based upon eight measurements. No single measurement should be greater than 3.6 m (140 in.) or less than 1.5 m (60 in.).Stainless steel bowls purchased with an absorptometer have been pre-polished for 16 h to m
18、inimize bowl surface changes affecting calibration during theirinitial use. It is recommended that new replacement stainless steel bowls should also be pre-polished to minimize the bowl surface effects on calibration(see Annex A1).8.1.1 The torque indicator is the primary component used to correct c
19、alibration. The load cell tension is adjusted by varying thealarm shut-off set point. Proper adjustment on the torque indicator should provide repeatable values for a silica sample dedicatedto internal reference.8.1.2 The maximum torque span is set at 10 000 mNm (10 000 units) torque value. The torq
20、ue-limit alarm is initially set at 5000mNm (5000 units), but for testing silicas it will be necessary to adjust this setting to a lower value in order to obtain reproducibleresults. Use an internal silica sample with a nitrogen surface area of 175 6 10 m2 /g to set the torque limit alarm which shoul
21、dcorrespond to approximately 70 % of the maximum torque developed during the test. After calibration, this setting should not bechanged.NOTE 2It is generally recommended to use the absorptometer in conjunction with a penwriter or preferably with a data acquisition system (see 9.9for further details)
22、.8.1.3 All digital signals are preset at 3 s damping for the torque sensing system.8.1.4 Properly maintain the surface finish of the mixing chamber. If a new mixer chamber is installed, frequently monitor theinstrument for any drift in calibration.8.2 Constant-Rate Buret:8.2.1 The delivery rate of t
23、he buret is to be 4 cm3/min. See Annex A1 for detailed instructions on the procedure for calibrationcheck of the constant-rate buret.9. Procedure9.1 Pass a suitable amount of the sample through Sieve No. 35 (500 m), using a brush in order to deglomerate larger particles.Use 2 g of the sieved materia
24、l to test the moisture content (see 9.2).9.2 Weigh 12.5 g of the sample to the nearest 0.01 g.NOTE 3For silicas with an extraordinary high pour density it may be necessary to increase the sample mass used for the test. This modification hasto be mentioned in the test report.9.3 It is recommended tha
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD68542012ARED7500STANDARDTESTMETHODFORSILICAOILABSORPTIONNUMBER 硅石 吸油值 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-523779.html