《ASTM D6769-2002 Standard Guide for Application of Fully Adhered Cold-Applied Prefabricated Reinforced Modified Bituminous Membrane Waterproofing Systems《完全粘结的寒冷条件下使用的预制增强改良沥青薄膜防水系统.pdf》由会员分享,可在线阅读,更多相关《ASTM D6769-2002 Standard Guide for Application of Fully Adhered Cold-Applied Prefabricated Reinforced Modified Bituminous Membrane Waterproofing Systems《完全粘结的寒冷条件下使用的预制增强改良沥青薄膜防水系统.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6769 02Standard Guide forApplication of Fully Adhered, Cold-Applied, PrefabricatedReinforced Modified Bituminous Membrane WaterproofingSystems1This standard is issued under the fixed designation D 6769; the number immediately following the designation indicates the year oforiginal ado
2、ption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide lists application and installation requirementsfor fully ad
3、hered, cold-applied, prefabricated modified bitumi-nous membrane waterproofing systems for below-grade orbelow-wearing-surface (such as plaza decks) vertical or hori-zontal applications.1.2 For the purposes of this application guide, the substrateis assumed to be structurally sound, sloped to drain
4、(if newconstruction), and meeting the local building code require-ments. Similarly, the system components are assumed tocomply with all federal, state, and local requirements in effectat the time of installation.1.3 The values in SI units are to be regarded as standard.The values in parentheses are
5、for information only.1.4 This guide may involve hazardous materials, operations,and equipment. This standard does not purport to address allof the safety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practi
6、ces and determine the applica-bility of regulatory requirements prior to use.2. Referenced Documents2.1 ASTM Standards:D 1079 Terminology Relating to Roofing, Waterproofing,and Bituminous Materials2D 5295 Guide for Preparation of Concrete Surfaces forAdhered (Bonded) Membrane Waterproofing Systems2D
7、 5898 Guide for Standard Details for Adhered SheetWaterproofing2D 5957 Guide for Flood Testing Horizontal WaterproofingInstallations23. Terminology3.1 Definitions:3.1.1 lift, nthe height or length of sheet that may becomfortably handled by the person applying the sheet to avertical surface. This is
8、normally the height of this person, or1.5 to 2.1 m (5 to 7 ft).3.1.2 skin over, na condition in which the surface of thematerial is no longer tacky, but will move under slight fingerpressure.3.1.3 tack, na condition in which if the surface is touched,there will be a string of material attached to th
9、e finger.3.2 For definitions of other terms relating to waterproofing,see Terminology D 1079.4. Significance and Use4.1 This guide outlines general procedures for the storageand application of various prefabricated sheets made usingmodified bituminous materials and intended for use as below-grade an
10、d below-wearing-surface waterproofing.4.2 The substrate used for applications described in thisguide shall be concrete or masonry.4.3 This application consists of a prefabricated reinforcedmodified bituminous sheet applied to a suitable substrate usinga bituminous-based, cold-applied adhesive or mas
11、tic. Applica-tion rates given are typical for such installations.4.4 This guide is intended to supplement instructions fromdesigners and manufacturers.5. Delivery of Materials5.1 Deliver materials in suppliers original containers andpackaging.6. Storage and Handling6.1 Store adhesive or mastic in ti
12、ghtly closed originalcontainers under the conditions recommended by the manufac-turer.6.2 Store the modified bituminous sheet in the manufactur-ers original packaging in the manner specified by the manu-facturer. Storage on wood pallets and stacking usually no morethan five rolls high is recommended
13、. Protect against exposureto direct sunlight, precipitation, dust, and other such contami-nants. If inside storage is not available, tarp only with canvastarpaulins; do not use polyethylene or other nonbreathing films1This guide is under the jurisdiction of ASTM Committee D08 on Roofing,Waterproofin
14、g, and Bituminous Materials and is the direct responsibility ofSubcommittee D08.22 on Waterproofing and Damproofing Systems.Current edition approved Feb. 10, 2002. Published April 2002.2Annual Book of ASTM Standards, Vol 04.04.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West C
15、onshohocken, PA 19428-2959, United States.to cover the packages.7. Safety Precautions7.1 Store flammable materials in a manner that will not posea fire hazard. Solvent-bearing adhesives may be flammable. Donot use flammable materials near an open flame or equipmentthat may produce sparks.8. Environm
16、ental Conditions at Time of Application8.1 Environmental conditions under which installation mayproceed shall be as recommended by the manufacturer of theadhesive and the sheet. Acceptable weather conditions wouldbe dry enough to allow the mastic to adhere to the substrate,without excessive wind con
17、ditions and with surface tempera-tures of the substrate at 4C (40F) or above and rising. Contactthe manufacturer for recommendations whenever weatherconditions raise questions.9. Materials9.1 The waterproofing sheet shall be made using a fabric ofopen weave glass and polyester, or both, which in tur
18、n isencapsulated in a chloroprene- and butyl-rubber-modified as-phalt that also contains fillers, slow-curing agents, and ultra-violet inhibitors.9.2 The adhesive or mastic shall be made using an asphaltcutback with a Rule-66-type solvent into which has beenblended chloroprene- and butyl-type rubber
19、s for plasticityalong with inorganic fillers and ultraviolet inhibitors.10. Substrate Preparations10.1 Contaminants such as dirt, debris, loose materialsmoisture, or surface irregularities that would interfere with thesatisfactory installation and performance of the system shall beremoved. See Guide
20、 D 5295 for further details about surfacepreparation.11. Installation11.1 Apply the adhesive at a rate of 0.5 to 0.6 L/m2(1.25 to1.5 gal/100 ft2) as a thin coat and allow to dry to a tackycondition before covering with membrane so as to minimizeblistering of the applied membrane. Apply only as mucha
21、dhesive as can be covered with membrane before the adhesiveloses its tack. Rub in the membrane by brooming, handrolling,or similar method.11.2 Installation of reinforcement material is required at alltransitions, such as internal and external corners and at staticconcrete construction joints and cra
22、cks. Reinforcement is alsorequired where reinforcing bars, pipes, and conduits penetratethe membrane. The minimum reinforcement is one ply; thepreferred is two plies.11.2.1 Installations of reinforcement membrane applicationsare made before the normal sheet applications.11.2.2 Where additional plies
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD67692002STANDARDGUIDEFORAPPLICATIONOFFULLYADHEREDCOLDAPPLIEDPREFABRICATEDREINFORCEDMODIFIEDBITUMINOUSMEMBRANEWATERPROOFINGSYSTEMS

链接地址:http://www.mydoc123.com/p-523522.html