ASTM D6427 D6427M-2010 1250 Standard Practice for Handling Transportation and Storage of HFC-236fa 1 1 1 3 3 3-Hexafluoropropane (CF3CH2CF3)《三氟甲烷(HFC)-236fa 1 1 1 3 3 3-六氟丙烷的搬运 运输和.pdf
《ASTM D6427 D6427M-2010 1250 Standard Practice for Handling Transportation and Storage of HFC-236fa 1 1 1 3 3 3-Hexafluoropropane (CF3CH2CF3)《三氟甲烷(HFC)-236fa 1 1 1 3 3 3-六氟丙烷的搬运 运输和.pdf》由会员分享,可在线阅读,更多相关《ASTM D6427 D6427M-2010 1250 Standard Practice for Handling Transportation and Storage of HFC-236fa 1 1 1 3 3 3-Hexafluoropropane (CF3CH2CF3)《三氟甲烷(HFC)-236fa 1 1 1 3 3 3-六氟丙烷的搬运 运输和.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6427/D6427M 10Standard Practice forHandling, Transportation, and Storage of HFC-236fa,1,1,1,3,3,3-Hexafluoropropane (CF3CH2CF3)1This standard is issued under the fixed designation D6427/D6427M; the number immediately following the designation indicates theyear of original adoption or,
2、in the case of revision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers guidance and direction to suppliers,purchasers, and users in
3、 the handling, transportation, andstorage of HFC236fa.1.2 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues f
4、rom the two systems may result in non-conformancewith the standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the ap
5、plica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D6541 Specification for HFC-236fa, 1,1,1,3,3,3Hexafluo-ropropane, (CF3CH2CF3)2.2 CGA Standards:3C-6 Standards for Visual Inspection of Steel CompressedGas CylindersC-7 Guide to Preparation of Precautionary
6、 Labeling andMarking of Compressed Gas ContainersP-1 Safe Handling of Compressed Gases in ContainersSB-1 Hazards of Refilling Compressed Refrigerant (Halo-genated Hydrocarbon) Gas CylindersSB-5 Hazards of Reusing Disposable Refrigerant (Haloge-nated Hydrocarbon) Gas CylindersSB-18 Use of Refrigerant
7、 (Halogenated Hydrocarbon) Re-covery Cylinders2.3 U.S. Government Standards:4Code of Federal Regulations (CFR) Title 40, Part 82.106Code of Federal Regulations (CFR) Title 49, Part 173 U.S.Department of Transportation (DOT) Specifications,Shippers-General Requirements for Shipping and Packag-ingsCod
8、e of Federal Regulations (CFR) Title 49, Part 178 U.S.DOT Specifications for PackagingsCode of Federal Regulations (CFR) Title 49, Part180 Qualification and Maintenance of Packages3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 containersstorage vessel for HFC-236fa.3.1.2 cyli
9、nderscontainers of HFC-236fa.3.1.3 HFC-236fa1,1,1,3,3,3-hexafluoropropane, a com-pound used to inert or suppress a fire or explosion hazard.3.1.4 insulatedplaced in an isolated situation to protectand prevent the transfer of damage.4. Significance and Use4.1 This practice provides requirements for t
10、he handling,transportation, and storage of HFC236fa encountered indistribution through both commercial and military channels. Itis intended to ensure that HFC-236fa is handled, transported,and stored in such a way its physical properties are notdegraded. Transport may be by various means, such as, b
11、ut notlimited to, highway, rail, water, and air.5. Practice5.1 To ensure safe handling, loading, unloading, storing,and transporting of material, personnel shall be trained in theCGA publications and Title 49 CFR regulations as listed in 2.2and 2.3, respectively.5.2 Handling:5.2.1 Handling shall be
12、in accordance with P-1, Safe Han-dling of Compressed Gases in Containers.5.2.1.1 Personnel who handle or store, or both, cylinders ofHFC-236fa shall be trained properly to recognize and identify1This practice is under the jurisdiction of ASTM Committee D26 on Haloge-nated Organic Solvents and Fire E
13、xtinguishing Agents and is the direct responsi-bility of Subcommittee D26.09 on Fire Extinguishing Agents.Current edition approved June 1, 2010. Published July 2010. Originally approvedin 1999. Last previous edition approved in 2004 as D6427-99(2004). DOI:10.1520/D6427_D6427M-10.2For referenced ASTM
14、 standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Compressed Gas Association (CGA), 4221 Walney Rd., 5thFloor, Chan
15、tilly, VA 20151-2923, http:/.4Available from U.S. Government Printing Office Superintendent of Documents,732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401, http:/www.access.gpo.gov.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United
16、States.the characteristics of the product and the proper methods ofsafely handling full, partly full, and empty cylinders.5.2.2 All HFC-236fa transfers between storage containersand recycling processes shall be performed by personneltrained in handling procedures.5.2.2.1 Facility personnel must be t
17、rained in applicableCode of Federal Regulations (CFR) Title 49, Part 173 andCode of Federal Regulations (CFR) Title 49, Part 178, and theCGA documents referenced in 2.2.5.2.3 The HFC-236fa recycling and transfer processes shallbe in conjunction with the equipment specified by the manu-facturer.5.2.4
18、 The handling of HFC-236fa shall be in nonsmoking,heater-free, ventilated areas to preclude product accumulation.Provisions shall be made to ensure that service areas limitHFC-236fa concentrations to not exceed 15 % for 1 min and0.1 % for 8 h.5.2.5 Cylinders shall not be over filled. The liquid port
19、ion ofthe liquefied gases must not completely fill the containersinternal volume at any temperature up to and including 130F54C. The maximum permitted filling density for HFC-236fashall be 78 lb/ft31249 kg/m3. The maximum permitted fillingdensity for HFC-236fa pressurized with nitrogen to 360 psig25
20、.8 bar at 70F 21C shall be 72 lb/ft31153 kg/m3. Themaximum permitted filling density for HFC-236fa pressurizedwith nitrogen to 600 psig 42.4 bar at 70F 21C shall be 70lb/ft31121 kg/m3. Filling density requirements are specifiedin Code of Federal Regulations (CFR) Title 49, Part 173 andTitle 49 CFR,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD6427D6427M20101250STANDARDPRACTICEFORHANDLINGTRANSPORTATIONANDSTORAGEOFHFC236FA111333HEXAFLUOROPROPANECF3CH2CF3

链接地址:http://www.mydoc123.com/p-522485.html