1、Designation: D 6194 04An American National StandardStandard Test Method forGlow-Wire Ignition of Materials1This standard is issued under the fixed designation D 6194; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、 revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the minimum temperaturerequired to ignite insulating materials using a glowing heatsource. In a p
3、reliminary fashion, this test method differentiatesbetween the susceptibilities of different materials with respectto their resistance to ignition due to an electrically-heatedsource.1.2 This test method applies to molded or sheet materialsavailable in thicknesses ranging from 0.25 to 6.4 mm.1.3 Thi
4、s test method is not valid for determining the ignitionbehavior of complete electrotechnical equipment, since thedesign of the electrotechnical product influences the heattransfer between adjacent parts.1.4 This test method measures and describes the response ormaterials, products, or assemblies to
5、heat and flame undercontrolled conditions, but does not by itself incorporate allfactors required for fire hazard or fire risk assessment of thematerials, products, or assemblies under actual fire conditions.1.5 The values stated in SI units are to be regarded as thestandard. (See IEEE/ASTM SI-10 fo
6、r further details.)1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to
7、use. For specificprecautionary statements, see Section 9.1.7 Fire testing of products and materials is inherentlyhazardous, and adequate safeguards for personnel and propertyshall be employed in conducting these tests. Fire testinginvolves hazardous materials, operations, and equipment.NOTE 1Althoug
8、h this test method and IEC 60695-2-13 differ inapproach and in detail, data obtained using either are technically equiva-lent.2. Referenced Documents2.1 ASTM Standards:2D 1711 Terminology Relating to Electrical InsulationE 176 Terminology of Fire StandardsE 220 Test Method for Calibration of Thermoc
9、ouples byComparison TechniquesE 230 Specification and Temperature-Electromotive Force(EMF) Tables for Standardized ThermocouplesIEEE/ASTM SI-10 International System of Units (SI), TheModernized Metric System2.2 IEC Standard:IEC 60695-2-13: Fire Hazard TestingSection 20:Glowing/Hot-Wire Based Test Me
10、thodsGlow-Wire CoilIgnitability Test Method for Materials3IEC 60695-4: Fire Hazard TestingPart 4: TerminologyConcerning Fire Tests32.3 ISO Standard:ISO 13943: Fire SafetyVocabulary43. Terminology3.1 Definitions:3.1.1 Use Terminology E 176, ISO 13943, and IEC 60695-4for definitions of terms used in t
11、his test method and associatedwith fire issues. Where differences exist in definitions, thosecontained in Terminology E 176 shall be used. Use Terminol-ogy D 1711 for definitions of terms used in this test method andassociated with electrical insulation materials.3.2 Definitions of Terms Specific to
12、 This Standard:3.2.1 glow wire, na wire of specified dimensions that canbe controllably-heated electrically to determine ignitability of amaterial.3.2.1.1 DiscussionFig. 1 shows a glow wire and itspositioning.3.2.2 ignition, ninitiation of combustion.1This test method is under the jurisdiction of AS
13、TM Committee D09 onElectrical and Electronic Insulating Materials and is the direct responsibility ofSubcommittee D09.21 on Fire Performance Standards.Current edition approved Sept. 1, 2004. Published September 2004. Originallyapproved in 1997. Last previous edition approved in 2003 as D 6194 03.2Fo
14、r referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from International Electrotechnical Commission (IEC),
15、 3 Rue deVarembe, Geneva, Switzerland.4Use undyed, soft, strong, lightweight tissue paper weighing between 12 and 30g/m2.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2.2.1 DiscussionIgnition is deemed to have taken placewhen the
16、 first of the following occurs: sustained flaming on thetest specimen surface for over5sorfalling particles causingthe appearance of flames on a tissue paper placed underneaththe test specimen.4. Summary of Test Method4.1 In this test method, a standardized test specimen (eithersquare or round), is
17、supported vertically and is exposed toelectrical heating from a glow-wire set at pre-determinedtemperatures. The minimum temperature for glow-wire igni-tion is assessed through testing at incremental temperatures.5. Significance and Use5.1 During operation of electrical equipment, includingwires, re
18、sistors, and other conductors, it is possible for over-heating to occur under certain conditions of operation, or whenmalfunctions occur. When this happens, a possible result isignition of the adjacent insulation material.5.2 This test method assesses the susceptibility of electricalinsulating mater
19、ials to ignition as a result of exposure to aglowing wire.5.3 This test method determines the minimum temperaturerequired to ignite a material by the effect of a glowing heatsource, under the specified conditions of test.5.4 This method is suitable, subject to the appropriatelimitations of an expect
20、ed precision of 615 %, to categorizematerials.5.5 In this procedure, the specimens are subjected to one ormore specific sets of laboratory conditions. If different testconditions are substituted or the end-use conditions arechanged, it is not always possible by or from this test to predictchanges in
21、 the fire-test-response characteristics measured.Therefore, the results are valid only for the fire test exposureconditions described in this procedure.6. Apparatus6.1 Glow-WireThe glow-wire shall be a Nichrome(Nickel-Chrome) wire, that is iron free, with the followingnominal properties: a wire comp
22、osition of 20 % chromium-80 % nickel, a diameter of 4 mm, and it shall be formed to thedimensions shown in Fig. 1.6.2 ThermocoupleUse Type K sheathed fine-wire thermo-couple, having an overall diameter of 1.0 mm max, and wiressuitable for continuous operation at temperatures up to 960 C,with the wel
23、ded point located inside the sheath, for measuringthe temperature of the glow-wire. Examples of suitable wirecompositions are Nickel-Chromium (NiCr) and Nickel-Aluminum (NiAl).6.2.1 Construct the thermocouple sheath of a metal that willallow the thermocouple to perform its function in air at sheatht
24、emperatures of at least 1050 C. Arrange the thermocouple isarranged in a pocket hole, drilled in the tip of the glow-wire, asshown in Fig. 1. Maintain the thermal contact between thewalls of the bored hole in the glow-wire by pinning theNOTE 1All dimensions in millimetres.FIG. 1 Glow-Wire and Positi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD61942004STANDARDTESTMETHODFORGLOWWIREIGNITIONOFMATERIALS 材料 辉光 点燃 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-521819.html