ASTM D6137-1997(2012) 3696 Standard Test Method for Sulfuric Acid Resistance of Polymer Linings for Flue Gas Desulfurization Systems《燃气脱硫系统用聚合衬垫的耐硫酸性的标准试验方法》.pdf
《ASTM D6137-1997(2012) 3696 Standard Test Method for Sulfuric Acid Resistance of Polymer Linings for Flue Gas Desulfurization Systems《燃气脱硫系统用聚合衬垫的耐硫酸性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6137-1997(2012) 3696 Standard Test Method for Sulfuric Acid Resistance of Polymer Linings for Flue Gas Desulfurization Systems《燃气脱硫系统用聚合衬垫的耐硫酸性的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6137 97 (Reapproved 2012)Standard Test Method forSulfuric Acid Resistance of Polymer Linings for Flue GasDesulfurization Systems1This standard is issued under the fixed designation D6137; the number immediately following the designation indicates the year oforiginal adoption or, in the
2、 case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is intended to evaluate the sulfuric acidresistance at elevated temper
3、atures of polymer linings appliedto carbon steel substrates subject to sulfuric acid attack.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered st
4、andard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Refer
5、enced Documents2.1 ASTM Standards:2A36/A36M Specification for Carbon Structural SteelC868 Test Method for Chemical Resistance of ProtectiveLiningsD660 Test Method for Evaluating Degree of Checking ofExterior PaintsD661 Test Method for Evaluating Degree of Cracking ofExterior PaintsD714 Test Method f
6、or Evaluating Degree of Blistering ofPaintsD772 Test Method for Evaluating Degree of Flaking (Scal-ing) of Exterior PaintsD1186 Test Methods for Nondestructive Measurement ofDry Film Thickness of Nonmagnetic Coatings Applied toa Ferrous Base (Withdrawn 2006)3D1474 Test Methods for Indentation Hardne
7、ss of OrganicCoatingsD4138 Practices for Measurement of Dry Film Thickness ofProtective Coating Systems by Destructive, Cross-Sectioning MeansD4417 Test Methods for Field Measurement of SurfaceProfile of Blast Cleaned SteelD5162 Practice for Discontinuity (Holiday) Testing of Non-conductive Protecti
8、ve Coating on Metallic Substrates2.2 Steel Structures Painting Council Standards4SSPC VIS 189 Visual StandardSSPC No. SP5 Blast Cleaning to White Metal3. Significance and Use3.1 The results obtained by this test method can be used incombination with other test methods for the selection of alining fo
9、r surfaces in flue gas desulfurization (FGD) systemsthat will be exposed to hot unscrubbed flue gas or to scrubbedgas that has been reheated well above the water dew point.3.1.1 This test method does not evaluate or correlate to areaswithin the scrubber or scrubbed gas streams at temperatures ator b
10、elow the water dew point.3.2 This test method is intended to evaluate the combinedeffects of heat and exposure to sulfuric acid upon a liningsystem as applied to a carbon steel substrate. It does notproduce the thermal gradient through the lining that may existin actual applications. Actual lining p
11、erformance may also beaffected by concurrent physical or mechanical effects and otherchemicals that may be present in the flue gas.3.3 This test method evaluates major failure modes oflinings applied to square test panels that are cycled from roomtemperature to a designated elevated temperature.3.4
12、The recommended test temperatures of 200F (93C)and 350F (177C) are based on typical maximum operatingzone temperatures in flue gas desulfurizations systems. Othertemperatures may be evaluated as desired. Cycling to lowertemperatures, including freezing, may be considered if appli-cable.1This test me
13、thod is under the jurisdiction of ASTM Committee D33 onProtective Coating and Lining Work for Power Generation Facilities and is the directresponsibility of Subcommittee D33.09 on Protective Lining for FGD Systems.Current edition approved Dec. 1, 2012. Published December 2012. Originallyapproved 199
14、7. Last previous edition approved in 2004 as D6137 97 (2004). DOI:10.1520/D6137-97R12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary
15、 page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.4Available from Society for Protective Coatings (SSPC), 40 24th St., 6th Floor,Pittsburgh, PA 15222-4656, http:/www.sspc.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700,
16、West Conshohocken, PA 19428-2959. United States13.5 The standard acid concentration for all tests is 20 %,recognizing that the concentration will quickly rise to theequilibrium at the selected test temperature.4. Apparatus4.1 Forced Air Circulation Oven, capable of maintaining theselected test tempe
17、rature 64 F (2C). Note that acid fumesmay damage the oven and a drip pan and protective shroudmay be needed.4.2 Rack or Stand, to support the test panels vertically in theoven while maintaining a distance of at least 1 in. (25 mm)between the panels and between the panels and oven walls.5. Test Speci
18、men5.1 Substrate:5.1.1 Test panels shall be new commercial quality, carbonsteel conforming to Specification A36/A36M. Panels shall be aminimum of14-in. (6-mm) thick, and 8-in. (200-mm) square,and shall have their edges broken or radiused if the lining is tobe wrapped over the edges of the panel.5.1.
19、2 These test panels are large enough and rigid enoughfor linings and coatings up to14-in. thick. For thicker linings,the test panels shall be at least 32 times the lining thickness inheight and width.5.1.3 Two control test panels shall be prepared for eachlining system tested. One shall be cycled be
20、tween the selectedtemperatures without exposure to acid. The second shall bemaintained at laboratory conditions without exposure to eitherelevated temperature or acid.5.2 Preparation:5.2.1 Prepare one side of each panel in accordance withSteel Structures Painting Council SSPC No. SP 5 to the degreeo
21、f cleanliness represented in SPC VIS 189 . Clean, new,angular abrasive shall be used. The surface profile shall be asrecommended by the lining manufacturer. Determine andrecord the average profile depth in accordance with PracticeD4417, Method A using a visual surface profile comparator ormethod B.
22、using a tape replica.5.2.2 Apply the lining to the prepared surface of the testpanels in a manner as closely simulating field application aspossible and in accordance with the manufacturers recommen-dations. Record the manufacturers batch numbers, manufac-turing dates, mixing method, mixing time, an
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD6137199720123696STANDARDTESTMETHODFORSULFURICACIDRESISTANCEOFPOLYMERLININGSFORFLUEGASDESULFURIZATIONSYSTEMS

链接地址:http://www.mydoc123.com/p-521656.html