ASTM D6137-1997(2004) Standard Test Method for Sulfuric Acid Resistance of Polymer Linings for Flue Gas Desulfurization Systems《燃气脱硫系统用聚合衬垫的耐硫酸性的标准试验方法》.pdf
《ASTM D6137-1997(2004) Standard Test Method for Sulfuric Acid Resistance of Polymer Linings for Flue Gas Desulfurization Systems《燃气脱硫系统用聚合衬垫的耐硫酸性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6137-1997(2004) Standard Test Method for Sulfuric Acid Resistance of Polymer Linings for Flue Gas Desulfurization Systems《燃气脱硫系统用聚合衬垫的耐硫酸性的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6137 97 (Reapproved 2004)Standard Test Method forSulfuric Acid Resistance of Polymer Linings for Flue GasDesulfurization Systems1This standard is issued under the fixed designation D 6137; the number immediately following the designation indicates the year oforiginal adoption or, in t
2、he case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is intended to evaluate the sulfuric acidresistance at elevated tem
3、peratures of polymer linings appliedto carbon steel substrates subject to sulfuric acid attack.1.2 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only.1.3 This standard does not purport to address all of thesafety concerns,
4、 if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2A 36/A 36M Specification for Carbon Structur
5、al SteelC 868 Test Method for Chemical Resistance of ProtectiveLiningsD 660 Test Method for Evaluating Degree of Checking ofExterior PaintsD 661 Test Method for Evaluating Degree of Cracking ofExterior PaintsD 714 Test Method for Evaluating Degree of Blistering ofPaintsD 772 Test Method for Evaluati
6、ng Degree of Flaking (Scal-ing) of Exterior PaintsD 1186 Test Methods for Nondestructive Measurement ofDry Film Thickness of Nonmagnetic Coatings Applied toa Ferrous BaseD 1474 Test Method for Indentation Hardness of OrganicCoatingsD 4138 Test Methods for Dry Film Thickness of ProtectiveCoating Syst
7、ems by Destructive MeansD 4417 Test Method for Field Measurement of SurfaceProfile of Blast Cleaned SteelD 5162 Practice for Discontinuity (Holiday) Testing ofNonconductive Protective Coating on Metallic Substrates2.2 Steel Structures Painting Council Standards3SSPC VIS 189 Visual StandardSSPC No. S
8、P5 Blast Cleaning to White Metal3. Significance and Use3.1 The results obtained by this test method can be used incombination with other test methods for the selection of alining for surfaces in flue gas desulfurization (FGD) systemsthat will be exposed to hot unscrubbed flue gas or to scrubbedgas t
9、hat has been reheated well above the water dew point.3.1.1 This test method does not evaluate or correlate to areaswithin the scrubber or scrubbed gas streams at temperatures ator below the water dew point.3.2 This test method is intended to evaluate the combinedeffects of heat and exposure to sulfu
10、ric acid upon a liningsystem as applied to a carbon steel substrate. It does notproduce the thermal gradient through the lining that may existin actual applications. Actual lining performance may also beaffected by concurrent physical or mechanical effects and otherchemicals that may be present in t
11、he flue gas.3.3 This test method evaluates major failure modes oflinings applied to square test panels that are cycled from roomtemperature to a designated elevated temperature.3.4 The recommended test temperatures of 200F (93C)and 350F (177C) are based on typical maximum operatingzone temperatures
12、in flue gas desulfurizations systems. Othertemperatures may be evaluated as desired. Cycling to lowertemperatures, including freezing, may be considered if appli-cable.1This test method is under the jurisdiction of ASTM Committee D33 onProtective Coating and Lining Work for Power Generation Faciliti
13、es and is the directresponsibility of Subcommittee D33.09 on Protective Lining for FGD Systems.Current edition approved January 1, 2004. Published January 2004. Originallyapproved 1997. Last previous edition approved in 1997 as D 6137 97.2For referenced ASTM standards, visit the ASTM website, www.as
14、tm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from The Society for Protective Coatings (SSPC), 40 24th St., 6thFloor, Pittsburgh, PA 15222-4656.1Copyright AST
15、M International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.5 The standard acid concentration for all tests is 20 %,recognizing that the concentration will quickly rise to theequilibrium at the selected test temperature.4. Apparatus4.1 Forced Air Circulatio
16、n Oven, capable of maintaining theselected test temperature 6 4 F (2C). Note that acid fumesmay damage the oven and a drip pan and protective shroudmay be needed.4.2 Rack or Stand, to support the test panels vertically in theoven while maintaining a distance of at least 1 in. (25 mm)between the pane
17、ls and between the panels and oven walls.5. Test Specimen5.1 Substrate:5.1.1 Test panels shall be new commercial quality, carbonsteel conforming to Specification A 36/A 36M. Panels shall bea minimum of14-in. (6-mm) thick, and 8-in. (200-mm) square,and shall have their edges broken or radiused if the
18、 lining is tobe wrapped over the edges of the panel.5.1.2 These test panels are large enough and rigid enoughfor linings and coatings up to14-in. thick. For thicker linings,the test panels shall be at least 32 times the lining thickness inheight and width.5.1.3 Two control test panels shall be prepa
19、red for eachlining system tested. One shall be cycled between the selectedtemperatures without exposure to acid. The second shall bemaintained at laboratory conditions without exposure to eitherelevated temperature or acid.5.2 Preparation:5.2.1 Prepare one side of each panel in accordance withSteel
20、Structures Painting Council SSPC No. SP 5 to the degreeof cleanliness represented in SPC VIS 189. Clean, new,angular abrasive shall be used. The surface profile shall be asrecommended by the lining manufacturer. Determine andrecord the average profile depth in accordance with PracticeD 4417, Method
21、A using a visual surface profile comparator ormethod B. using a tape replica.5.2.2 Apply the lining to the prepared surface of the testpanels in a manner as closely simulating field application aspossible and in accordance with the manufacturers recommen-dations. Record the manufacturers batch numbe
22、rs, manufac-turing dates, mixing method, mixing time, and method ofapplication.5.2.3 The lining may be terminated at the edges of the panelor may be wrapped around the panel edges.5.2.4 The lining thickness shall be as specified by themanufacturer.5.2.5 The lined surface of the panel may be scribed
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD613719972004STANDARDTESTMETHODFORSULFURICACIDRESISTANCEOFPOLYMERLININGSFORFLUEGASDESULFURIZATIONSYSTEMS

链接地址:http://www.mydoc123.com/p-521655.html