1、Designation: D5492 10D5492 17Standard Test Method forDetermination of Xylene Solubles in Propylene Plastics1This standard is issued under the fixed designation D5492; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、 revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method is to be used for determining the 25C xylene-soluble fraction of polypropylene homopolymers andcopolymer
3、s.1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.NOTE 1This test
4、 method is technically equivalent to ISO 16152.1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety, health and environmental practices and determine the applica
5、bility ofregulatory limitations prior to use.NOTE 1This test method is technically equivalent to ISO 16152.1.3 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decision on Principles for the Development of Interna
6、tional Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D883 Terminology Relating to PlasticsD1600 Terminology for Abbreviated Terms Relating to PlasticsE456 Terminology Relating to Qual
7、ity and StatisticsE691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test MethodE2935 Practice for Conducting Equivalence Testing in Laboratory Applications2.2 ISO Standard:ISO 16152 PlasticsDetermination of Xylene Solubles of Polypropylene33. Terminology3.1 Defini
8、tions:3.1.1 For definitions of plastic terms see Terminology D883 and for abbreviations see Terminology D1600.3.2 Definitions of Terms Specific to This Standard:3.2.1 soluble-fraction (SS)the percentage of the polymer mass that does not precipitate out when the polymer solution iscooled from reflux
9、temperature to +25 6 0.5C and held at that temperature for a specified period of time.4. Summary of Test Method4.1 A weighed amount of sample is dissolved in xylene under reflux conditions. The solution is cooled under controlledconditions and maintained at a +25C equilibrium temperature so that the
10、 crystallization of the insoluble fraction takes place.When1 This test method is under the jurisdiction of ASTM Committee D20 on Plastics and is the direct responsibility of Subcommittee D20.15 on Thermoplastic Materials.Current edition approved Aug. 1, 2010Aug. 1, 2017. Published September 2010Augu
11、st 2017. Originally approved in 1994. Last previous edition approved in 20062010as D5492 - 06.D5492 - 10. DOI: 10.1520/D5492-10.10.1520/D5492-17.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsv
12、olume information, refer to the standards Document Summary page on the ASTM website.3 Available from American National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indic
13、ation of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be co
14、nsidered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1the solution is cooled the insoluble portion precipitates and is isolated by filtration. T
15、he xylene is evaporated from the filtrate,leaving the soluble fraction in the residue. The percentage of this fraction in the plastic is determined gravimetrically.5. Significance and Use5.1 The results of this test provide a relative measure of the total soluble fraction of polypropylene homopolyme
16、rs andcopolymers. The soluble fraction approximately correlates to the amorphous fraction in the polypropylene. Xylene is widely usedfor determining the soluble fraction in polypropylene as it is more specific to the atactic fraction than other solvents. Theconcentration of a soluble fraction obtain
17、ed with a specific solvent has been found to relate closely to the performancecharacteristics of a product in certain applications, for example film and fiber. Data obtained by one solvent and at one precipitationtime cannot be compared with data obtained by another solvent or precipitation time, re
18、spectively.6. Interferences6.1 It is possible that materials with solubilities similar to the soluble fraction, such as additives, can interfere with themeasurement of solubles. When present in concentrations that are judged to impart a significant error to the soluble-fraction data,the level of int
19、erference must be determined and corrections made.6.2 It is possible that small-particle fillers and pigments and insoluble gels present in the polymer can pass through the filterand cause errors in the measurement.6.3 The polymer flakes and spheres must be dried before testing to eliminate moisture
20、 that can influence the initial weight ofsample added to the flask.7. Apparatus7.1 Reflux-Condenser Apparatus, Reflux-Condenser Apparatus,minimum 400 mm,mL, with 24/40 glass joint.7.1.1 The use a teflon seal sleeve around the glass joint is an acceptable option provided it has been determined that c
21、omponentsfrom the sleeve or tape are not extracted by the xylene.7.1.2 The use of silicone greases or other greases shall be avoided.7.2 Flat- or Round-Bottom Boiling Flask, Flat-Bottom Boiling Flask,with one or two necks, minimum 400 mLwith 24/40 joint,Erlenmeyer flask, or flat-bottomed cylindrical
22、 bottle.7.3 Insulation Disk, Insulation Disk,made of fiberglass or rock wool.7.4 Electromagnetic Stirrer Unit, Electromagnetic Stirrer Unit,with temperature-controlled heating plate, thermostatted oil bath,or heater blockheater block, or heating mantle capable of maintaining 145 to 150C.7.5 Stirring
23、 Bar.Stirring Bar.7.6 Pipet, Pipet,Class A, 200 mL or equivalent.7.7 Pipet, Pipet,Class A, 100 mL or equivalent.7.8 Glass-Stoppered Volumetric Flask, Glass-Stoppered Volumetric Flask,250 mL.7.9 Thermostatically Controlled Water Bath, Thermostatically Controlled Water Bath,at +25 6 0.5C.7.10 Electrom
24、agnetic Stirrers.Electromagnetic Stirrers.7.11 Filter Paper, Filter Paper,fluted, Whatman No. 4, No. 541,4 or equivalent, at least 125 mm in diameter.7.12 Funnel, Funnel,60, or equivalent, at least 125 mm in diameter.7.13 Heated Vacuum Oven.Heated Vacuum Oven.7.14 Aluminum Aluminum Pans,or stainless
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD54922017STANDARDTESTMETHODFORDETERMINATIONOFXYLENESOLUBLESINPROPYLENEPLASTICS 测定 丙烯 塑料 二甲苯 溶解度 标准

链接地址:http://www.mydoc123.com/p-519947.html