《ASTM D5390-1993(2013) Standard Test Method for Open-Channel Flow Measurement of Water with Palmer-Bowlus Flumes《Palmer-Bowlus量水槽测量水的明渠流量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5390-1993(2013) Standard Test Method for Open-Channel Flow Measurement of Water with Palmer-Bowlus Flumes《Palmer-Bowlus量水槽测量水的明渠流量的标准试验方法》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5390 93 (Reapproved 2013)Standard Test Method forOpen-Channel Flow Measurement of Water with Palmer-Bowlus Flumes1This standard is issued under the fixed designation D5390; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisi
2、on, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers measurement of the volumetricflowrate of water and wastewater in sewers and ot
3、her openchannels with Palmer-Bowlus flumes.1.2 The values stated in inch-pound units are to be regardedas the standard. The SI units given in parentheses are forinformation only.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is therespons
4、ibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1129 Terminology Relating to WaterD1941 Test Method for Open Channel Flow Measurementof Water
5、 with the Parshall FlumeD2777 Practice for Determination of Precision and Bias ofApplicable Test Methods of Committee D19 on WaterD3858 Test Method for Open-Channel Flow Measurementof Water by Velocity-Area MethodD5242 Test Method for Open-Channel Flow Measurementof Water with Thin-Plate Weirs2.2 IS
6、O Standards:3ISO 4359 Liquid Flow Measurement in Open ChannelsRectangular, Trapezoidal and U-Shaped FlumesISO 555 Liquid Flow Measurements in Open ChannelsDilution Methods for Measurement of Steady FlowConstant Rate Injection Method32.3 ASME Standard:4Fluid Meters Their Theory and Application3. Term
7、inology3.1 DefinitionsFor definitions of terms used in this testmethod refer to Terminology D1129.3.2 Definitions of Terms Specific to This Standard:3.2.1 boundary layer displacement thickness the bound-ary layer is a layer of fluid flow adjacent to a solid surface (inthis case, the flume throat) in
8、 which, owing to viscous friction,the velocity increases from zero at the stationary surface to anessentially frictionless-flow value at the edge of the layer. Thedisplacement thickness is a distance normal to the solid surfacethat the surface and flow streamlines can be considered to havebeen displ
9、aced by virtue of the boundary-layer formation.3.2.2 critical flowopen channel flow in which the energyexpressed in terms of depth plus velocity head, is a minimumfor a given flowrate and channel. The Froude number is unityat critical flow.3.2.3 Froude numbera dimensionless number expressingthe rati
10、o of inertial to gravity forces in free-surface flow. It isequal to the average velocity divided by the square root of theproduct of the average depth and the acceleration due togravity.3.2.4 headthe depth of flow referenced to the floor of thethroat measured at an appropriate location upstream of t
11、heflume; this depth plus the velocity head is often termed the totalhead or total energy head.3.2.5 hydraulic jumpan abrupt transition from supercriti-cal flow to subcritical or tranquil flow, accompanied byconsiderable turbulence or gravity waves, or both.3.2.6 long-throated flumea flume in which t
12、he prismaticthroat is long enough relative to the head for essentially criticalflow to develop on the crest.3.2.7 primary instrumentthe device (in this case theflume) that creates a hydrodynamic condition that can besensed by the secondary instrument.1This test method is under the jurisdiction of AS
13、TM Committee D19 on Waterand is the direct responsibility of Subcommittee D19.07 on Sediments,Geomorphology, and Open-Channel Flow.Current edition approved Jan. 1, 2013. Published January 2013. Originallyapproved in 1993. Last previous edition approved in 2007 as D5390 93 (2007).DOI: 10.1520/D5390-9
14、3R13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (A
15、NSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.4Available from American Society of Mechanical Engineers (ASME), ASMEInternational Headquarters, Three Park Ave., New York, NY 10016-5990, http:/www.asme.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West
16、Conshohocken, PA 19428-2959. United States13.2.8 Reynolds numbera dimensionless number express-ing the ratio of inertial to viscous forces in a flow. In a flumethroat the pertinent Reynolds number is equal to the (critical)throat velocity multiplied by the throat length and divided bythe kinematic v
17、iscosity of the water.3.2.9 scow floatan in-stream float for depth sensing,usually mounted on a hinged cantilever.3.2.10 secondary instrumentin this case, a device thatmeasures the depth of flow (referenced to the throat elevation)at an appropriate location upstream of the flume. The second-ary inst
18、rument may also convert this measured head to anindicated flowrate, or could totalize flowrate.3.2.11 stilling wella small free-surface reservoir con-nected through a restricted passage to the approach channelupstream of the flume so that a head measurement can be madeunder quiescent conditions.3.2.
19、12 subcritical flowopen channel flow that is deeperand at lower velocity than critical flow for the same flowrate;sometimes called tranquil flow.3.2.13 submergencea condition where the depth of flowimmediately downstream of the flume is large enough to affectthe flow through the flume so that the fl
20、owrate can no longer berelated to a single upstream head.3.2.14 supercritical flowopen channel flow that is shal-lower and at higher velocity than critical flow for the sameflowrate.3.2.15 tailwaterthe water elevation immediately down-stream of the flume.3.2.16 throatthe constricted portion of the f
21、lume.3.2.17 velocity headthe square of the average velocitydivided by twice the acceleration due to gravity.4. Summary of Test Method4.1 In Palmer-Bowlus flumes, critical free-surface flow isdeveloped in a prismatic throat so that the flowrate is a uniquefunction of a single measured upstream head f
22、or a given throatshape and upstream channel geometry. This function can beobtained theoretically for ideal (frictionless) flows and adjust-ments for non-ideal conditions can be obtained experimentallyor estimated from fluid-mechanics considerations.5. Significance and Use5.1 Although Palmer-Bowlus f
23、lumes can be used in manytypes of open channels, they are particularly adaptable forpermanent or temporary installation in circular sewers. Com-mercial flumes are available for use in sewers from 4 in. to 6ft (0.1 to 1.8 m) in diameter.5.2 A properly designed and operated Palmer-Bowlus iscapable of
24、providing accurate flow measurements while intro-ducing a relatively small head loss and exhibiting goodsediment and debris-passing characteristics.6. Interferences6.1 Flumes are applicable only to open-channel flow andbecome inoperative under full-pipe flow conditions.6.2 The flume becomes inoperat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD539019932013STANDARDTESTMETHODFOROPENCHANNELFLOWMEASUREMENTOFWATERWITHPALMERBOWLUSFLUMESPALMERBOWLUS

链接地址:http://www.mydoc123.com/p-519660.html