《ASTM D4952-2012(2017) Standard Test Method for Qualitative Analysis for Active Sulfur Species in Fuels and Solvents (Doctor Test)《燃料和溶剂中活性硫类物质定性分析的标准试验方法(试硫液试验)》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4952-2012(2017) Standard Test Method for Qualitative Analysis for Active Sulfur Species in Fuels and Solvents (Doctor Test)《燃料和溶剂中活性硫类物质定性分析的标准试验方法(试硫液试验)》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4952 12 (Reapproved 2017)Standard Test Method forQualitative Analysis for Active Sulfur Species in Fuels andSolvents (Doctor Test)1This standard is issued under the fixed designation D4952; the number immediately following the designation indicates the year oforiginal adoption or, in t
2、he case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1
3、 This test method covers and is intended primarily for thedetection of mercaptans in motor fuel, kerosine, and similarpetroleum products. This method may also provide informationon hydrogen sulfide and elemental sulfur that may be present inthese sample types.1.2 The values stated in SI units are to
4、 be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and
5、 determine the applica-bility of regulatory limitations prior to use.1.4 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-m
6、endations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent WaterD3227 Test Method for (Thiol Mercaptan) Sulfur inGasoline, Kerosine, Aviation Turbine, and Distillate Fuels(Potentiometric Metho
7、d)2.2 Energy Institute Standards:3IP 30 Detection of Mercaptans, Hydrogen Sulfide, ElementalSulfur, and Peroxides Doctor Test Method3. Summary of Test Method3.1 The sample is shaken with sodium plumbite solution, asmall quantity of powdered sulfur added, and the mixtureshaken again. The presence of
8、mercaptans or hydrogen sulfideor both is indicated by discoloration of the sulfur floating at theoil-water interface or by discoloration of either of the phases.4. Significance and Use4.1 Sulfur present as mercaptans or as hydrogen sulfide indistillate fuels and solvents can attack many metallic and
9、non-metallic materials in fuel and other distribution systems. Anegative result in the doctor test ensures that the concentrationof these compounds is insufficient to cause such problems innormal use.5. Interferences5.1 This test cannot be used if there are more than traceamounts of peroxides in the
10、 test sample. Peroxides can give afalse positive results where mercaptans are at low level or noteven present.45.2 To check if peroxides are present in sufficient concen-tration to invalidate the test, shake 10 mL 6 0.5 mL of a freshportion of the sample with approximately 2 mL of the potas-sium iod
11、ide solution, add two drops of the acetic acid solution,and two drops of the starch solution. If the aqueous layer turnsa blue color, this confirms the presence of peroxides insufficient quantity to invalidate the test, and the test on thissample should be discontinued. Proceed in accordance with5.4
12、.5.3 Alternatively, one may choose to perform a preliminaryDoctor Test. If a brown precipitate slowly forms, peroxide isprobably present. Proceed in accordance with 5.2 to confirmpresence of peroxides at sufficient quantity to invalidate thetest.5.4 If interference from peroxides is confirmed, proce
13、ed tore-sample and retest. Ensure that sampling and handlingprocedures for the new sample prevent UV light exposures as1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products, Liquid Fuels, and Lubricants and is the direct responsibility ofSubcommittee D02.03 on Elemen
14、tal Analysis.Current edition approved May 1, 2017. Published June 2017. Originallyapproved in 1989. Last previous edition approved in 2012 as D4952 12. DOI:10.1520/D4952-12R17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. Fo
15、r Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Energy Institute, 61 New Cavendish St., London, WIG 7AR,U.K., http:/www.energyinst.org.4Brooks, B. T., “Sodium Plumbite or Doctor Test of Gasolines,” Industrial andEngin
16、eering Chemistry, Vol 16, No. 6, June 1924, p. 588.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the
17、 Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1prescribed in 7.1. None of the normal refinery units or blendingprocesses producing spark ignition motor fuels are kno
18、wn tocreate peroxides under normal operating conditions.6. Reagents and Materials6.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents conform to the specifications of the Committee onAnalytical Reagents of the American C
19、hemical Society wheresuch specifications are available.5Other grades may be used,provided it is first ascertained that the reagent is of sufficientlyhigh purity to permit its use without lessening the accuracy ofthe determination.6.2 Purity of WaterUnless otherwise indicated, referencesto water shal
20、l be understood to mean reagent water as definedby Types II or III of Specification D1193.6.3 Doctor (Sodium Plumbite) Solution(WarningPoisonous and suspect carcinogen.) Dissolve approximately125 g of sodium hydroxide (NaOH) in 1 L of reagent water.Add 60 g of lead monoxide (PbO) and shake vigorousl
21、y for15 min, or let stand with occasional shakings for at least oneday. Allow to settle and decant or siphon off the clear liquid. Ifthe solution does not settle clear, filter it through filter paper.Keep the solution in a tightly sealed bottle and refilter beforeuse if not perfectly clear. As an al
22、ternative, the lab may use acommercially prepared solution that meets the requirements ofthe laboratory preparation.NOTE 1Alternative volumes of the solution may be prepared orpurchased, provided the final solution concentration is equivalent.6.4 SulfurPure, sublimed, stored in a closed container.6.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD495220122017STANDARDTESTMETHODFORQUALITATIVEANALYSISFORACTIVESULFURSPECIESINFUELSANDSOLVENTSDOCTORTEST

链接地址:http://www.mydoc123.com/p-518489.html