ASTM D4765-2003(2008) Standard Test Method for Fluorides in Workplace Atmospheres《工作场所大气中氟化物的标准试验方法》.pdf
《ASTM D4765-2003(2008) Standard Test Method for Fluorides in Workplace Atmospheres《工作场所大气中氟化物的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4765-2003(2008) Standard Test Method for Fluorides in Workplace Atmospheres《工作场所大气中氟化物的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 4765 03 (Reapproved 2008)Standard Test Method forFluorides in Workplace Atmospheres1This standard is issued under the fixed designation D 4765; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisio
2、n. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the simultaneous collection andseparate measurements of gaseous and particulate fluoridefound in certain i
3、ndustrial workplaces. The gaseous inorganicfluorides collected are reported in terms of fluoride; theprocedure is not applicable to the collection or analysis of otherfluoride-bearing gases (for example, fluorocarbon or fluorosul-fur compounds). This test method covers sample collection,preparation,
4、 and fluoride measurement.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations pr
5、ior to use.2. Referenced Documents2.1 ASTM Standards:2D 1193 Specification for Reagent WaterD 1356 Terminology Relating to Sampling and Analysis ofAtmospheresD 1357 Practice for Planning the Sampling of the AmbientAtmosphereD 5337 Practice for Flow Rate Calibration of PersonalSampling Pumps3. Termin
6、ology3.1 DefinitionsFor definitions of terms used in this testmethod, refer to Terminology D 1356.4. Summary of Test Method4.1 Particulate material from a measured volume of air iscollected by means of a membrane filter. Gaseous fluoride,from the sample of air, is absorbed by an alkali-impregnatedce
7、llulose pad placed immediately behind the membrane filter.The membrane filter and collected solids are made alkaline,ashed, and the residue fused with additional alkali. Finally, thefluoride is determined in a solution of the melt by use of afluoride ion-selective electrode. Gaseous fluoride is dete
8、rminedin an aqueous extract of the cellulose pad, also by means of thefluoride ion-selective electrode.5. Significance and Use5.1 The capability of this test method to collect and quan-titate both particulate and gaseous fluorides over the rangesnormally encountered in industrial atmospheres makes i
9、t ap-plicable for industrial hygiene evaluation and control purposes.The recommended range of this test method is from 0.005 to 5mg F/m3air.6. Interferences6.1 Because an ion-selective electrode responds to ionicactivity, insoluble and complex forms of fluoride must bereleased by appropriate combina
10、tions of fusion, adjustment ofpH, and addition of complexing agents.6.2 Acidity (pH) and ionic strengths of fluoride standardsolutions must be matched to those of samples.6.3 Temperature of sample and standard solutions must becontrolled within 62C.7. Apparatus7.1 Personal Sampling Pump, Equipped wi
11、th a flow-monitoring device (rotameter, critical orifice) or a constant-flow device capable of drawing 2 L/min of air through the0.8-m membrane filter and pad for a period of 8 h.7.2 Filter HolderPlastic holders of the preloaded personalmonitor type, that accept filters of 37-mm diameter, arepreferr
12、ed. The holder is to be numbered for identification.7.3 Membrane Filter, of mixed-cellulose esters, 0.8-mpore size, and of diameter to fit the filter holder (see 7.2).7.4 Cellulose Pad, of size to fit the filter holder (see 7.2).The pad is commercially available as a plain, unpregnated pador as an a
13、lkali-impregnated pad.7.5 Crucibles, 20-mL, nickel, Inconel,3or platinum.7.6 Fluoride Ion-Selective Electrode.7.7 Reference Electrode, calomel type, preferably combinedwith the fluoride ion-selective electrode.1This test method is under the jurisdiction of ASTM Committee D22 on AirQuality and is the
14、 direct responsibility of Subcommittee D22.04 on Workplace AirQuality.Current edition approved April 1, 2008. Published July 2008. Originallyapproved in 1988. Last previous edition approved in 2003 as D 4765 03.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Cust
15、omer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Inconel is a trademark for a group of corrosion-resistant alloys of nickel andchromium.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C
16、700, West Conshohocken, PA 19428-2959, United States.7.8 Electrometer or Expanded Scale pH Meter, with amillivolt scale for measurement of potentials.7.9 Magnetic Stirrer.7.10 Plastic Beakers, 50 and 100-mL capacities.7.11 Beakers, 250-mL capacity.7.12 Volumetric Flasks, 100-mL capacity.8. Reagents8
17、.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available.48.2 Purity of Wat
18、erUnless otherwise indicated, referencesto water shall be understood to mean Type I Reagent Waterconforming to Specification D 1193.8.3 Alkaline Fixative SolutionDissolve 25 g of sodiumcarbonate (Na2CO3) in water, add 20 mLglycerol, and dilute to1L.8.4 Buffer Solution (ALCOA)Dissolve 60 g of citric
19、acidmonohydrate (C2H8O7H2O), 210 g of sodium citrate(Na3C6H5O72H2O) and 53.5 g of ammonium chloride(NH4Cl) in 500 mLwater.Add 67 mLof ammonium hydroxide(NH4OH) (sp gr = 0.90) and dilute to 1 L with water.8.5 Fluoride Solution, Standard (100 g/mL)Dissolve0.2211 g sodium fluoride (NaF, dried at 105C f
20、or 2 h) in waterand dilute to volume in a 1-L volumetric flask.8.6 Ethanol, DenaturedFormula 30 denatured alcohol issatisfactory.8.7 Borate-Carbonate Fusion MixtureIntimately mix a1+2 (w/w) combination of sodium tetraborate (Na2B4O7) andsodium carbonate (Na2CO3).8.8 Hydrochloric Acid (1+1)Mix one pa
21、rt hydrochloricacid to one part distilled water as a solution.9. Sampling9.1 For general information on sampling, refer to PracticeD 1357.9.2 Equip the worker whose exposure is to be evaluatedwith a personal monitor connected by a 75-cm length of hoseto a belt-supported sampling pump. Attach the mon
22、itor to theworkers collar and remove the plug for closed-face sampling.Air is drawn through the filter at the calibrated rate ofapproximately 2.0 L/min and maintained at that rate byoccasional checking and adjustment. On termination of sam-pling, note the duration of sampling, reseal the monitor and
23、return the monitor to the laboratory. Filter a minimum airsample of 250 L.9.3 Total particulate loading may be determined, if required,by pre- and post-weighing of the membrane filter.10. Preparation of Monitors10.1 Disassemble the personal monitor (see 7.2), removingthe membrane filter and cellulos
24、e pads. Moisten the pad with ameasured volume of alkaline fixative solution (see 8.3); 0.8 mLis required for a pad of 37-mm diameter. Dry the pad at 105Cfor 30 to 45 min.NOTE 1Preparation of alkali-impregnated pads must be carried out ina low-fluoride environment with minimum exposure.10.2 Reassembl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD476520032008STANDARDTESTMETHODFORFLUORIDESINWORKPLACEATMOSPHERES 工作 场所 大气 氟化物 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-517923.html