《ASTM D4025-2008a(2013) Standard Practice for Reporting Results of Examination and Analysis of Deposits Formed from Water for Subsurface Injection《报告地下喷射的水中沉积物的检验和分析结果的标准操作规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4025-2008a(2013) Standard Practice for Reporting Results of Examination and Analysis of Deposits Formed from Water for Subsurface Injection《报告地下喷射的水中沉积物的检验和分析结果的标准操作规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4025 08a (Reapproved 2013)Standard Practice forReporting Results of Examination and Analysis of DepositsFormed from Water for Subsurface Injection1This standard is issued under the fixed designation D4025; the number immediately following the designation indicates the year oforiginal a
2、doption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the manner in which the variousresults of examin
3、ation and analysis to determine the composi-tion of deposits formed from water for subsurface injection areto be reported.1.2 All analyses shall be made in accordance with the testmethods of ASTM, unless otherwise specified.NOTE 1While reporting of inorganic constituents in water-formeddeposits as s
4、pecified in Test Methods D4412 is sufficient for certainindustries, this practice provides for the reporting of organic and biologi-cal materials as well as inorganic constituents.NOTE 2Consistent with practices in industries where subsurfaceinjection of water is practiced, reporting includes specif
5、ying of inorganicconstituents as probable molecular combinations of the species for whichanalyses are performed.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety c
6、oncerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D887 Practices for Sampling Water-Fo
7、rmed DepositsD932 Test Method for Iron Bacteria in Water and Water-Formed DepositsD933 Practice for Reporting Results of Examination andAnalysis of Water-Formed DepositsD1129 Terminology Relating to WaterD4412 Test Methods for Sulfate-Reducing Bacteria in Waterand Water-Formed DepositsE29 Practice f
8、or Using Significant Digits in Test Data toDetermine Conformance with Specifications3. Terminology3.1 DefinitionsFor definitions of terms used in thispractice, reference should be made to Terminology D1129 andPractice D887.4. History of Sample4.1 Information regarding the source and history of thesa
9、mple shall be included in the report of the analysis. Thisinformation should be that supplied by the individual submit-ting the sample as follows:4.1.1 Name of company supplying the sample,4.1.2 Name of location of plant, facility, and well,4.1.3 Date and time of sampling,4.1.4 Number of sample,4.1.
10、5 Name and other designation of equipment from whichsample was removed,4.1.6 Precise location from which sample was removed,4.1.7 Operating temperature and pressure of water or brineat location of deposit,4.1.8 Type of treatment applied to the water that formed thedeposit,4.1.9 An account of system
11、operating conditions that mayhave contributed to deposition (for example, filter channeling,chemical pump outage, or increased system temperature),4.1.10 Appearance and extent of deposit prior to removal,4.1.11 Exact method that was used in removing the sampleand notes concerning any contamination t
12、hat might haveoccurred during the process,4.1.12 Specific methods used for preservation of sampleprior to and subsequent to removal,4.1.13 Results of field tests made on the sample or relatedequipment,4.1.14 An analysis of the water from which the deposit wasformed, and4.1.15 Identity of sampler.1Th
13、is practice is under the jurisdiction of ASTM Committee D19 on Water andis the direct responsibility of Subcommittee D19.05 on Inorganic Constituents inWater.Current edition approved June 1, 2013. Published July 2013. Originally approvedin 1981. Last previous edition approved in 2008 as D4025 08a. D
14、OI: 10.1520/D4025-08AR13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Ba
15、rr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15. Significance and Use5.1 This practice sets down the manner in which dataobtained from other test methods should be reported. This isdone in an effort to standardize the report form used.6. Physical Characteristics6.1 Th
16、e macroscopic characteristics of the sample, as ascer-tained by the analyst, including any peculiarities that may bepertinent to the results of the examination, shall be included inthe report.NOTE 3Characteristics such as the following may be recorded: color,form (scaly, slimy, etc.), texture (oily,
17、 smooth, friable, gritty, etc.),magnetic properties (as determined by test with magnet), and apparentstructure (amorphous, crystalline, columnar crystals).NOTE 4Any discrepancies between the physical characteristics ob-served by the analyst and those reported by the sampler should be noted.6.2 Chara
18、cteristics observed during microscopic examina-tion shall be reported and include a description of the grosscharacteristics and homogeneity or heterogeneity of thesample.6.3 Any distinct observable crystal morphology such asmonoclinic, rhombic, etc., shall be reported.NOTE 5Specific note of the pres
19、ence of any biological material in thesample should be made.7. Determinations to Be Reported7.1 The major headings for which determinations shall bereported in a complete analysis are as indicated in Table 1.Specific determinations which shall be reported under some ofthe major headings are listed i
20、n Tables 2-4. In certain instances,knowledge of the operating practices and water chemistry willhave suggested the need to perform additional analyses orindicated the need for a less complete analysis; consequently,results from determinations may not be reported for eachindividual item.8. Reporting
21、of Biological Components8.1 The results of examinations conducted to determine thepresence of microorganisms in the sample, such as thosedelineated by Test Method D932 and Practice D4412, shall bereported. The organisms present should be identified by phylawith the relative abundance noted.NOTE 6In
22、the absence of quantitative measurements, the microbio-logical constituents may be grouped as major, minor, and trace. Incategorizing the constituents, the qualitative nature of the examination andthe subjective appraisal of its proportion must be considered.NOTE 7The results of the examination shou
23、ld be qualified on the basisof any known or suspected effects related to sample handling prior to orduring analysis likely to influence the validity.9. Reporting of Chemical Analyses9.1 The major headings under which chemical analysisdetermination shall be reported are moisture and volatilematerial,
24、 solvent-extractable components, loss at 900C, ash,and inorganic components.9.2 All data shall be reported as weight percent both on anas-received basis and on a dry weight basis, with the exceptionof water and volatile material, which shall be reported on anas-received basis only.TABLE 1 Major Head
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD40252008A2013STANDARDPRACTICEFORREPORTINGRESULTSOFEXAMINATIONANDANALYSISOFDEPOSITSFORMEDFROMWATERFORSUBSURFACEINJECTION

链接地址:http://www.mydoc123.com/p-516085.html