ASTM D3908-2003 Standard Test Method for Hydrogen Chemisorption on Supported Platinum on Alumina Catalysts and Catalyst Carriers By Volumetric Vacuum Method《容量真空法测定氧化铝催化剂和催化剂载体上的铂的.pdf
《ASTM D3908-2003 Standard Test Method for Hydrogen Chemisorption on Supported Platinum on Alumina Catalysts and Catalyst Carriers By Volumetric Vacuum Method《容量真空法测定氧化铝催化剂和催化剂载体上的铂的.pdf》由会员分享,可在线阅读,更多相关《ASTM D3908-2003 Standard Test Method for Hydrogen Chemisorption on Supported Platinum on Alumina Catalysts and Catalyst Carriers By Volumetric Vacuum Method《容量真空法测定氧化铝催化剂和催化剂载体上的铂的.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3908 03Standard Test Method forHydrogen Chemisorption on Supported Platinum Catalystsby Volumetric Vacuum Method1This standard is issued under the fixed designation D 3908; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revis
2、ion, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the chemi-sorption of hydrogen at 298 K (25C) on suppor
3、ted platinumcatalysts that have been reduced in flowing hydrogen at 723 K(450C). It incorporates a static volumetric vacuum techniqueat constant volume.1.2 The test method is intended for use on unused supportedplatinum on alumina catalysts of loadings greater than 0.3weight %. Data on other support
4、s and lower platinum loadingswere not tested.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regula
5、tory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 3766 Terminology Relating to Catalysts and CatalysisE 177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE 456 Terminology Relating to Quality and StatisticsE 691 Practice for Conducting an Interlaborator
6、y Study toDetermine the Precision of a Test Method3. Terminology3.1 DefinitionsSee Terminology D 3766.3.2 Quality and StatisticsSee Terminology E 456.3.3 Precision and BiasSee Practice E 177.3.4 SymbolsThe following symbols are used:Pc= pressure of gas in calibrated bulb, torrPmc= pressure of gas in
7、 calibrated bulb andmanifold, torrPm= pressure in manifold, torrPmd= pressure in manifold and dead space, torrPmx= pressure in manifold prior to expansion intosample tube for X equilibration point, torrPex= equilibrium pressure after expansion forgenerating X equilibrium point, torrVc= volume of cal
8、ibrated bulb, cm3Vm= volume of manifold between stopcocks 12and 2 with only 4 and 1 open, cm3Vd= volume of dead space in sample cell con-taining catalyst (volume between 2 and 3),cm3Vads(STP)x= volume of gas adsorbed at STP, cm3Vads(STP)cx= cumulative volume of gas adsorbedthrough X,cm3VS= monolayer
9、 volume of gas adsorbed at STP,cm3TmAx= temperature representative of the manifoldprior to expansion into the sample cell, KTmBx= temperature representative of the entire sys-tem after equilibrium pressure (Pex) hasbeen established, KTm= temperature of manifold prior to expansioninto sample cell for
10、 dead space determina-tion, KTmD= temperature of entire system after equilib-rium pressure has been established for deadspace determination, KT = average manifold temperature for a givendose, K=(TmAx+ TmBx)/2Wcat= mass of catalyst, gX = weight percent of platinum%D = percent platinum atoms on the su
11、rface1This test method is under the jurisdiction of ASTM Committee D32 onCatalysts and is the direct responsibility of Subcommittee D32.01 on Physical-Chemical Properties.Current edition approved Oct. 1, 2003. Published October 2003. Originallyapproved in 1980. Last previous edition approved in 1999
12、 as D 390899.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor D
13、rive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4. Significance and Use4.1 This test method sets forth a procedure by whichduplicate catalyst samples can be compared either on aninterlaboratory or intralaboratory basis. It is anticipated thatcatalyst producers and users will find
14、this test method of value.4.2 Discrimination of the samples for which this procedureis recommended must be exercised when considering carrier(support) materials that sorb appreciable quantities of hydrogenor could cause an alteration of the state of the catalyst duringpretreatment, or both, (that is
15、, sintering or metal occlusion).These materials must be identified by the user and experi-mented with to determine the most significant conditions ofmeasurement.4.3 This test method provides a measure of the totalhydrogen uptake (volume of hydrogen at STP, cm3/g ofcatalyst) without specifying the na
16、ture of the hydrogen-platinum interaction. Persons interested in using hydrogenuptake data to calculate percent platinum dispersion in aspecific catalyst should be aware of carrier (support) interac-tions, spill-over effects, and other phenomena related to thehydrogen uptake capabilities of the cata
17、lyst in question.5. Apparatus5.1 Gas-Handling System, as shown in Fig. 1. The compo-nents may be either glass or metal. Commercial metal instru-ments are available. The following components are to beincluded in the glass system:5.1.1 Vacuum System, capable of attaining pressures below1 mPa (1 3 105t
18、orr). The vacuum can be monitored with anysuitable vacuum gage. A diffusion pump backed by a mechani-cal pump must be isolated from the system by a trap held atliquid nitrogen temperature. High-vacuum stopcocks using alow-vapor pressure grease can be employed.5.1.2 Pressure-Measuring Device, that op
19、erates at constantvolume and that is capable of reading in the range from 0 to66.7 kPa (0 to 500 torr) to the nearest 0.01 kPa (0.1 torr).5.1.3 Calibration Bulb, whose volume has been carefullydetermined to within 0.1 % prior to attachment to the mainmanifold. Typically one fills the bulb and stopco
20、ck bore withmercury, weighs it, and calculates the volume of the bulb fromthe density of mercury at the temperature of the measurement.Following careful cleaning, the bulb is attached to the mainmanifold. One should make sure that the glass blowing issufficiently far removed from the calibrated volu
21、me to avoiddistortion.5.1.4 Flow-Through Cell, that can be evacuated and that canbe detached from the main manifold as, for example, see Fig.2. This is accomplished by including a removable joint, ifglass, a male cone joint, on the manifold end of the tube. (Othertypes of joints, that is, Swagelok w
22、ith TFE-fluorocarbonfittings, and so forth, are suitable.) Its mate is attached to themain manifold by a glass vacuum stopcock. A stopcock is alsoincluded on the vent side of the cell to allow for vacuum andflow-through procedures.5.1.5 Catalyst Sample, secured by a quartz wool plugupstream of the c
23、atalyst and another quartz wool plug down-stream (Fig. 2). The sample should be in the form of anextrudate, pellets, or powder greater than 20 mesh.5.1.6 Furnace, capable of maintaining a heating rate of5 K/min and a temperature-control mechanism capable ofmaintaining the furnace at temperatures in
24、the range from 673to 773 6 10 K (400 to 500 C).5.1.7 Thermometer or Thermocouple, to monitor the fur-nace temperature to within 65 K and two thermometers toregister the temperature of the manifold system and sample cellduring uptake determination to the nearest 60.1 K.5.1.8 Balance, measuring to the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD39082003STANDARDTESTMETHODFORHYDROGENCHEMISORPTIONONSUPPORTEDPLATINUMONALUMINACATALYSTSANDCATALYSTCARRIERSBYVOLUMETRICVACUUMMETHOD

链接地址:http://www.mydoc123.com/p-515774.html