ASTM D3675-2008 Standard Test Method for Surface Flammability of Flexible Cellular Materials Using a Radiant Heat Energy Source.pdf
《ASTM D3675-2008 Standard Test Method for Surface Flammability of Flexible Cellular Materials Using a Radiant Heat Energy Source.pdf》由会员分享,可在线阅读,更多相关《ASTM D3675-2008 Standard Test Method for Surface Flammability of Flexible Cellular Materials Using a Radiant Heat Energy Source.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3675 08Standard Test Method forSurface Flammability of Flexible Cellular Materials Using aRadiant Heat Energy Source1This standard is issued under the fixed designation D 3675; the number immediately following the designation indicates the year oforiginal adoption or, in the case of r
2、evision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This is a fire test response standard.1.2 This test method describes the measurement of surfacef
3、lammability of flexible cellular materials.1.3 This standard measures and describes the response ofmaterials, products, or assemblies to heat and flame undercontrolled conditions, but does not, by itself, incorporate allfactors required for fire hazard or fire risk assessment of thematerials, produc
4、ts, or assemblies under actual fire conditions.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regu
5、latory limitations prior to use.1.5 Fire testing of products and materials is inherentlyhazardous, and adequate safeguards for personnel and propertyshall be employed in conducting these tests. This test methodmay involve hazardous materials, operations and equipment.Specific information about hazar
6、ds is given in Section 7.NOTE 1There is no similar or equivalent ISO standard.1.6 The values stated in SI units are to be regarded as thestandard. The values stated in inch-pound units, in brackets, arefor information only and are approximations (see also IEEE/ASTM SI-10).2. Referenced Documents2.1
7、ASTM Standards:2E84 Test Method for Surface Burning Characteristics ofBuilding MaterialsE 162 Test Method for Surface Flammability of MaterialsUsing a Radiant Heat Energy SourceE 176 Terminology of Fire StandardsE 1317 Test Method for Flammability of Marine SurfaceFinishesE 1321 Test Method for Dete
8、rmining Material Ignition andFlame Spread PropertiesE 1546 Guide for Development of Fire-Hazard-AssessmentStandardsIEEE/ASTM SI-10 Standard for Use of the InternationalSystem of Units (SI): The Modern Metric System2.2 ISO Standards:3ISO 13943 Fire SafetyVocabulary3. Terminology3.1 Definitions:3.1.1
9、For definitions of terms used in this test method, referto the terminology contained in Terminology E 176 andISO 13943. In case of conflict, the definitions given in Termi-nology E 176 shall prevail.3.1.2 flame front, nthe leading edge of a flame propagat-ing through a gaseous mixture or across the
10、surface of a liquidor solid.3.2 Definitions of Terms Specific to This Standard:3.2.1 flashing, nflame fronts of three seconds or less induration.3.2.2 radiant panel index, Is, nthe product of the flamespread factor, Fsand the heat evolution factor, Q.4. Summary of Test Method4.1 This test method of
11、measuring surface flammability offlexible cellular materials employs a radiant panel heat sourceconsisting of a 300 by 460-mm (12 by 18-in.) panel in front ofwhich an inclined 150 by 460-mm (6 by 18-in.) specimen ofthe material is placed. The orientation of the specimen is suchthat ignition is force
12、d near its upper edge and the flame frontprogresses downward.4.2 Factors derived from the rate of progress of the flamefront and the rate of heat liberated by the material under test arecombined to provide a radiant panel index.5. Significance and Use5.1 This test method is intended for use when mea
13、suringsurface flammability of flexible cellular materials exposed tofire. The test method provides a laboratory test procedure for1This test method is under the jurisdiction of ASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.30 on Thermal Properties.Current edition
14、 approved Aug. 1, 2008. Published September 2008. Originallyapproved in 1978. Last previous edition approved in 2005 as D 3675 - 05.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume inform
15、ation, refer to the standards Document Summary page onthe ASTM website.3Available from International Standardization Organization, P.O. Box 56,CH-1211; Geneva 20, Switzerland.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Bo
16、x C700, West Conshohocken, PA 19428-2959, United States.measuring and comparing the surface flammability of materialswhen exposed to a prescribed level of radiant heat energy. Thetest is conducted using specimens that are representative, to theextent possible, of the material or assembly being evalu
17、ated.For example, if an assembly is required to be tested, suchspecimens shall replicate the type and thickness of all thelayers present in the assembly being evaluated.5.2 The rate at which flames will travel along surfacesdepends upon the physical and thermal properties of thematerial, product, or
18、 assembly under test, the specimen mount-ing method and orientation, the type and level of fire or heatexposure, the availability of air, and properties of the surround-ing enclosure. (1-6)4, 55.3 Test Method E 162 is a generic version of this testmethod, using an apparatus that is substantially the
19、 same as theone used in this test method. However, Test Method E 162 isnormally intended for application to specimens other thanflexible cellular materials.5.3.1 The pilot burner in this test method is different fromthe pilot burner in Test Method E 162.5.4 In this procedure, the specimens are subje
20、cted to one ormore specific sets of laboratory fire test conditions. If differenttest conditions are substituted or the end-use conditions arechanged, it is not always possible by or from this test to predictchanges in the fire-test-response characteristics measured.Therefore, the results are valid
21、only for the fire test exposureconditions described in this procedure.5.5 If the test results obtained by this test method are to beconsidered as part of an overall assessment of fire hazard in abuilding or structure, then the criteria, concepts and proceduresincorporated into Guide E 1546 shall be
22、taken into consider-ation.6. Apparatus6.1 The apparatus shall be essentially as shown in Fig. 1 andshall include the following:6.1.1 Radiant Panel with Air and Gas SupplyThe radiantpanel shall consist of a porous refractory material verticallymounted in a cast iron frame, exposing a radiating surfac
23、e of300 by 460 mm (12 by 18 in.) and shall be capable of operatingat temperatures up to 820C (1500F). The panel shall beequipped (see Fig. 1) with a venturi-type aspirator for mixinggas and air at approximately atmospheric pressure; a centrifu-gal blower, or equivalent, to provide 47 dm3/s (100 ft3/
24、min) airat a pressure of 0.7 kPa (2.8 in. water); an air filter to preventdust from obstructing the panel pores; a pressure regulator anda control and shut-off valve for the gas supply.6.1.2 Specimen HolderThe specimen holder shall con-form in shape and dimension to Fig. 2 and be constructed fromhea
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD36752008STANDARDTESTMETHODFORSURFACEFLAMMABILITYOFFLEXIBLECELLULARMATERIALSUSINGARADIANTHEATENERGYSOURCEPDF

链接地址:http://www.mydoc123.com/p-515231.html