ASTM D3354-2015 Standard Test Method for Blocking Load of Plastic Film by the Parallel Plate Method《采用平行板法的塑料薄膜阻挡承载力的标准试验方法》.pdf
《ASTM D3354-2015 Standard Test Method for Blocking Load of Plastic Film by the Parallel Plate Method《采用平行板法的塑料薄膜阻挡承载力的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3354-2015 Standard Test Method for Blocking Load of Plastic Film by the Parallel Plate Method《采用平行板法的塑料薄膜阻挡承载力的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D3354 11D3354 15Standard Test Method forBlocking Load of Plastic Film by the Parallel Plate Method1This standard is issued under the fixed designation D3354; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of
2、last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope Scope*1.1 This test method yields quantitative information regarding the degree of blocking (unwanted adhesion) existing
3、betweenlayers of plastic film. It is not intended to measure susceptibility to blocking.1.2 By this procedure, the film-to-film adhesion, expressed as a blocking load in grams, will cause two layers of film with anarea of contact of 100 cm2 to separate. The test method is limited to a maximum load o
4、f 200 g.1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establ
5、ish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.NOTE 1This test method is similar to ISO 11502 Method B, but is not technically equivalent.2. Referenced Documents2.1 ASTM Standards:2D618 Practice for Conditioning Plastics for TestingD
6、883 Terminology Relating to PlasticsE691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method2.2 ISO Standard:ISO 11502 Determination of Blocking Resistance33. Terminology3.1 DefinitionsFor definitions of terms used in this test method, refer to Terminology D8
7、83.4. Summary of Test Method4.1 Two pieces of film, which are in contact with each other, are placed between two 100-mm (4-in.) square blocks. The endsof the films that extend past the blocks are secured to the respective upper and lower block. The force required to overcome theadhesion (blocking fo
8、rce) between the two pieces of film or until they reach 1.9 cm of separation is measured in grams using aconstant-rate-of-load or a constant-rate-of separation device.5. Significance and Use5.1 Blocking develops in film processing and storage when layers of smooth film are in intimate contact with n
9、early completeexclusion of air. Temperature, or pressure, or both, can induce or change the degree of adhesion of the surfaces.5.2 The procedure of this test method closely simulates the operation of separating film in some end-use applications.6. Apparatus6.1 The parallel block faces shall be squar
10、e and 100 6 0.1 mm (on each edge with a flat and slightly knurled or sand-blastedfinish of root mean square 125). A means must be provided to prevent the blocks from sliding when they are in contact duringloading.1 This test method is under the jurisdiction of ASTM Committee D20 on Plastics and is t
11、he direct responsibility of Subcommittee D20.19 on Film, Sheeting, and MoldedProducts.Current edition approved May 1, 2011April 1, 2015. Published May 2011April 2015. Originally approved in 1974. Last previous edition approved in 20082011 asD3354 - 08.D3354 - 11. DOI: 10.1520/D3354-11.10.1520/D3354-
12、15.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 Available from American National Standards Institute (AN
13、SI), 25 W. 43rd St., 4th Floor, New York, NY 10036, http:/www.ansi.org.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depi
14、ct all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM Internation
15、al, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States16.2 Constant-Rate-of-Load Device4:6.2.1 An instrument with 100-cm2 (4-in.2) blocks which electronically times a loading rate of 90 grams per minute (61) (seeFig. 1). The force required to separate the blocks is d
16、isplayed electronically.NOTE 2On some constant-rate-of load devices, the weight is added by moving a weight axially along the beam with a precision-drive system. Thismay be accomplished using a stepper motor with a digital stepping drive with 60 cycles as its reference control. The load rate must be
17、 90 grams perminute.6.3 Constant-Rate-of-Separation Testing DeviceA testing machine of the constant-rate-of crosshead-movement type andcomprising essentially the following:6.3.1 Fixed MemberA fixed or essentially stationary member carrying one aluminum block 100 by 100 6 1 mm withappropriate rigid a
18、dapter for mounting in a universal testing machine.6.3.2 Movable MemberA movable member carrying a second aluminum block 100 by 100 6 1 mm with rigid coupling formounting in a universal testing machine.6.3.3 Drive MechanismA drive mechanism for imparting to the movable member a uniform, controlled v
19、elocity with respectto the stationary member. The speed of testing, 5.1 mm/min, is the rate of separation of the two blocks when running idle (underno load). This rate of separation shall be maintained within 5 % of the no-load value when running under full-capacity load.6.3.4 Load IndicatorA suitab
20、le load-indicating mechanism capable of showing the tensile load, the greater of 1 % of theindicated force or 5 grams, carried by the test specimen held by the block.6.4 Accessory EquipmentMay include a 100 by 180-mm template or die, double-faced pressure-sensitive tape.7. Test Specimens7.1 Cut unse
21、parated test specimens with a 100 by 180-mm template with the longer length being in the machine direction. Dueto variations in gage and blocking tendencies, it is desirable to select several sample locations across the width of the film. Five4 The sole source of supply of the electro mechanical app
22、aratus known to the committee at this time is Alpha Technologies, 3030 Gilchrist Road, Akron, OH 44305. hasdiscontinued production and the apparatus is no longer available. If you are aware of alternative suppliers, please provide this information to ASTM InternationalHeadquarters. Your comments wil
23、l receive careful consideration at a meeting of the responsible technical committee,1 which you may attend.FIG. 1 Electro-Mechanical DeviceD3354 152specimens shall be tested. If the test specimens are taken from a roll, care should be taken that the roll is in good condition. Bestresults are obtaine
24、d when specimens are taken at least 25 mm below the outer surface of film rolls.8. Conditioning8.1 ConditioningCondition the test specimens at 23 6 2C (73.4 6 3.6F) and 50 6 10 % relative humidity for not less than40 h prior to test in accordance with ProcedureAof Practice D618 unless otherwise spec
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD33542015STANDARDTESTMETHODFORBLOCKINGLOADOFPLASTICFILMBYTHEPARALLELPLATEMETHOD 采用 平行 塑料薄膜 阻挡 承载力

链接地址:http://www.mydoc123.com/p-514646.html