《ASTM D495-2014 Standard Test Method for High-Voltage Low-Current Dry Arc Resistance of Solid Electrical Insulation《固体电绝缘材料耐高压低电流干电弧性能的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D495-2014 Standard Test Method for High-Voltage Low-Current Dry Arc Resistance of Solid Electrical Insulation《固体电绝缘材料耐高压低电流干电弧性能的标准试验方法》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D495 14 An American National StandardStandard Test Method forHigh-Voltage, Low-Current, Dry Arc Resistance of SolidElectrical Insulation1This standard is issued under the fixed designation D495; the number immediately following the designation indicates the year oforiginal adoption or,
2、in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scop
3、e1.1 This test method covers, in a preliminary fashion, thedifferentiation of similar materialsresistance to the action of ahigh-voltage, low-current arc close to the surface of insulation,when a conducting path is formed causing the material tobecome conducting due to the localized thermal and chem
4、icaldecomposition and erosion.1.2 The usefulness of this test method is very severelylimited by many restrictions and qualifications, some of whichare described in the following paragraphs and in Section 5.Generally, this test method shall not be used in materialspecifications. Whenever possible, al
5、ternative test methodsshall be used, and their development is encouraged.1.3 This test method will not, in general, permit conclusionsto be drawn concerning the relative arc resistance rankings ofmaterials that are potentially subjected to other types of arcs:for example, high voltage at high curren
6、ts, and low voltage atlow or high currents (promoted by surges or by conductingcontaminants).1.4 The test method is intended, because of its convenienceand the short time required for testing, for preliminary screen-ing of material, for detecting the effects of changes informulation, and for quality
7、 control testing after correlation hasbeen established with other types of simulated service arc testsand field experience. Because this test method is usuallyconducted under clean and dry laboratory conditions rarelyencountered in practice, it is possible that the prediction of amaterials relative
8、performance in typical applications and invarying “clean to dirty” environments will be substantiallyaltered (Note 1). Caution is urged against drawing strongconclusions without corroborating support of simulated servicetests and field testing. Rather, this test method is useful forpreliminary evalu
9、ation of changes in structure and compositionwithout the complicating influence of environmentalconditions, especially dirt and moisture.NOTE 1By changing some of the circuit conditions described hereinit has been found possible to rearrange markedly the order of arcresistance of a group of organic
10、insulating materials consisting ofvulcanized fiber and of molded phenolic and amino plastics, somecontaining organic, and some inorganic, filler.1.5 While this test method uses dry, uncontaminated speci-men surfaces, Test Method D2132, Test Methods D2303, andTest Method D3638 employ wet, contaminate
11、d specimensurfaces. Their use is recommended for engineering purposesand to assist in establishing some degree of significance to thistest method for quality control purposes.21.6 This test method is not applicable to materials that donot produce conductive paths under the action of an electricarc,
12、or that melt or form fluid residues that float conductiveresidues out of the active test area thereby preventing forma-tion of a conductive path.1.7 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are p
13、rovided for information onlyand are not considered standard.1.8 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-b
14、ility of regulatory limitations prior to use. For specificprecautionary statements, see 6.1.14, 6.1.19, Section 7, and10.1.1.2. Referenced Documents2.1 ASTM Standards:3D1711 Terminology Relating to Electrical Insulation1This test method is under the jurisdiction of ASTM Committee D09 onElectrical an
15、d Electronic Insulating Materials and is the direct responsibility ofSubcommittee D09.12 on Electrical Tests.Current edition approved April 1, 2014. Published May 2014. Originallyapproved in 1938. Last previous edition approved in 2004 as D495 94 (2004),which was withdrawn in January 2013 and reinst
16、ated in April 2014. DOI:10.1520/D0495-14.2Also helpful is Test Method D2302 for Wet Tracking Resistance of ElectricalInsulating Materials with Controlled Water-to-Metal Discharges. This test methodwas withdrawn and last appeared in the 1982 Annual Book of ASTM Standards, Part39.3For referenced ASTM
17、standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocke
18、n, PA 19428-2959. United States1D2132 Test Method for Dust-and-Fog Tracking and ErosionResistance of Electrical Insulating MaterialsD2303 Test Methods for Liquid-Contaminant, Inclined-Plane Tracking and Erosion of Insulating MaterialsD3638 Test Method for Comparative Tracking Index ofElectrical Insu
19、lating MaterialsD6054 Practice for Conditioning Electrical Insulating Mate-rials for Testing (Withdrawn 2012)42.2 IEC Standard:IEC 61621 Dry Solid Insulating MaterialsResistance TestTo High-Voltage, Low-Current Arc Discharges5NOTE 2IEC 61621 is technically equivalent to D495, and is directlybased up
20、on Test Method D495. IEC 61621 describes only the tungstenelectrodes, and does not include the stainless steel electrodes.3. Terminology3.1 Definitions:3.1.1 For definitions of terms used in this test method, referto Terminology D1711.3.2 Definitions of Terms Specific to This Standard:3.2.1 arc resi
21、stance, nthe total elapsed time in secondsfrom the start of this test procedure until failure occurs (seeSection 14).3.2.2 failure, nthe end-point of the test procedure em-ployed in this test method (see Section 14).3.2.3 normal orientation, na test condition in which theelectrodes are located on th
22、e upper surface of the specimen.3.2.4 inverted orientation, na test condition in which theelectrodes are located on the under surface of the specimen.3.2.4.1 DiscussionTests made with inverted orientationare more severe than tests made with normal orientation.Reduced data dispersion has been encount
23、ered when testingcertain materials using inverted orientation. With othermaterials, increased data dispersion may be encountered,especially with materials that evolve considerable gas duringtest.3.3 Abbreviations:3.3.1 The stainless steel strip electrodes are referred to ass.s.s. electrodes.4. Signi
24、ficance and Use4.1 The high-voltage, low-current type of arc resistance testis intended to simulate only approximately such service con-ditions as exist in alternating current circuits operating at highvoltage, but at currents limited to units and tens of milliam-peres.4.2 In order to distinguish mo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD4952014STANDARDTESTMETHODFORHIGHVOLTAGELOWCURRENTDRYARCRESISTANCEOFSOLIDELECTRICALINSULATION 固体

链接地址:http://www.mydoc123.com/p-511798.html