ANSI IAPMO Z124.6-2007 Plastic Sinks《塑料洗池》.pdf
《ANSI IAPMO Z124.6-2007 Plastic Sinks《塑料洗池》.pdf》由会员分享,可在线阅读,更多相关《ANSI IAPMO Z124.6-2007 Plastic Sinks《塑料洗池》.pdf(29页珍藏版)》请在麦多课文档分享上搜索。
1、Plastic SinksIAPMO/ANSI Z124.6-2007Revision of ANSI Z124.6-1997A N A M E R I C A N N A T I O N A L S T A N D A R DIAPMO / ANSIZ124.6 - 2007Revision ofANSI Z124.6 - 1997American National Standardfor Plastic SinksSecretariatInternational Association ofPlumbing and Mechanical OfficialsApproved May 8, 2
2、007American National Standards Institute, Inc.Approval of an American National Standard requires verification by ANSI that therequirements for due process, consensus, and other criteria for approval have been met bythe standards developer.Consensus is established when, in the judgement of the ANSI B
3、oard of Standards Review,substantial agreement has been reached by directly and materially affected interests.Substantial agreement means much more than a simple majority, but not necessarily una-nimity. Consensus requires that all views and objections be considered, and that a con-certed effort be
4、made toward their resolution.The use of American National Standards is completely voluntary; their existence does notin any respect preclude anyone, whether he has approved the standards or not, from man-ufacturing, marketing, purchasing, or using products, processes, or procedures not con-forming t
5、o the standards.The American National Standards Institute does not develop standards and will in no cir-cumstances give an interpretation of any American National Standard. Moreover, no per-son shall have the right or authority to issue an interpretation of an American NationalStandard in the name o
6、f the American National Standards Institute. Requests for inter-pretations should be addressed to the secretariat or sponsor whose name appears on thetitle page of this standard.CAUTION NOTICE: This American National Standard may be revised or withdrawn atany time. The procedures of the American Nat
7、ional Standards Institute require that actionbe taken periodically to reaffirm, revise, or withdraw this standard. Purchasers ofAmerican National Standards may receive current information on all standards by callingor writing the American National Standards Institute.Published byInternational Associ
8、ation of Plumbing and Mechanical Officials5001 East Philadelphia Street, Ontario, CA 91761Copyright 2007 by International Association of Plumbing and Mechanical OfficialsAll rights reserved.No part of this publication may be reproduced in anyform, in an electronic retrieval system or otherwise,witho
9、ut prior written permission of the publisher.Printed in the United States of AmericaAmericanNationalStandardContentsPageForeword .iii1 Scope and Purpose 11.1 Scope .11.2 Purpose 11.3 Normative References .11.4 Definitions .12 General Requirements.12.1 Materials12.2 Dimensions and Tolerances 12.3 Uni
10、ts for Testing12.4 Installation Instructions .12.5 Care, and Maintenance Instructions12.6 Identification23 Workmanship and Finish 23.1 Unit Preparation 23.2 Method of Inspection of Unit Surface.23.3 Surface Test.23.4 Subsurface Test .24 Structural Integrity of Complete Units .34.1 Drain Fitting Conn
11、ection (All Sinks) .34.2 Impact Tests 44.2.1 Point Impact (All Sinks).44.2.2 Knife Drop Test (Kitchen and Bar Sinks Only).44.2.3 Skillet Drop Test (Kitchen Sinks Only) .44.3 Load Test (Kitchen, Service, and Laundry Sinks Only).44.4 Vibration Test45. Physical Characteristics of Materials45.1 Colorfas
12、tness and Aging Test (Kitchen and Bar Sinks Only) 45.2 Stain Resistance Test (All Sinks)55.3 Wear and Cleanability Test (All Sinks) 55.3.1 Specimen Preparation.55.3.2 Wear Test .65.3.3 Cleanability Test 65.4 Cigarette Test (All Sinks)75.5 Chemical Resistance Test (All Sinks).75.6 Heated Pan Test (Ki
13、tchen Sinks Only) .75.7 Hot Wax Test (Kitchen Sinks Only).86. Additional Material Tests .86.1 Thermal Shock Resistance Test(Kitchen, Laundry and Service Sinks Only) .86.2 Thermal Shock Resistance Test (Bar Sinks Only ) .87 Provisions for Government Procurement .8Tables1 Test Applicability to Sinks .
14、22 Appearance Requirements 33 Reagents Used in Stain Resistance Test.54 Brush Rotation Schedule.6iPageFigures1 Holes for Faucet and Outlet92 Load Test for Drain Fitting Connection .123 Point Impact Locations .124 Brush Holder (Sled) (Z124 Wear Test) 135 Platform 7.0% Ethoxylated-alkyl-phenol(Monsant
15、o Sterox NJ or Rohm and Haas Triton X-100 were used); 8.0%Sodium-xylene sulfonate (Stepan Chemical Co. Stepan SXS was used); 1.5%Ethylene Glycol Monobutyl Ether (2-butoxylethanol) (Union Carbide ButylCellosolve was used); and 75.5% water.3 To hasten drying, surfaces shall be permitted to be wiped wi
16、th a clean chamoisleather or a clean, absorbent, lint-free material (for this test only).4 “A“ weight or dry 600-grit silicon carbide abrasive paper manufactured by 3MCompany was used in preparing this test method.5 Standard dirt shall consists of: 20 parts carbon black (pigment grade); 20 partsiron
17、 black (iron oxide, black); 20 parts calcium stearate; 5 parts 30W motor oil;1 part wetting agent (Rohm and 44 parts tapwater. All parts shall be measured by weight.IAPMO/ANSI Z124.6-2007Table 1 - Test applicability to sinksClass of SinksTest Kitchen Bar Laundry Service3 Workmanship or delamination.
18、Inspection for cracking and crazing shall be made using anink solution as described in Section 3.3.1.7. Provisions for Government ProcurementWhen required by Government procurement documents, theinformation defined in Appendix II shall be specified by thepurchasers.8IAPMO/ANSI Z124.6-20079IAPMO/ANSI
19、 Z124.6-2007 * Providing faucet openingis optionalKitchen Sink Faucet Openings*(spray hole size and location optional)(Number of openings optional)Indicates flat surrounding areafor faucet opening11-1/4“(286 mm)5-5/8“(143 mm)2-1/2“(63 mm)1-3/8“ 1/8“ dia.(34.92 mm 3.18 mm)4“(101.6 mm)4“(101.6 mm)1-1/
20、8“ dia. min.(28.6 mm)* Providing faucet openingis optionalBar sink faucet openings*(number of openings optional)Indicates flat surrounding areafor faucet mounting6-3/4“(171.4 mm)3-3/8“(85.7 mm)2-1/2“(63 mm)2“(50.8 mm)4“(101.6 mm)2-1/2“ dia.(63 mm)1-1/4“ 1/4“ dia.(32 mm 6 mm)* Providing faucet openin
21、gis optionalLaundry tray faucet openings*(number of openings optional)Indicates flat surrounding areafor faucet mounting4“(101.6 mm)4“(101.6 mm)Figure 1 - Holes for faucet and outlet10IAPMO/ANSI Z124.6-20076-3/4“(171.4 mm)1-1/4“ 1/4“ DIA.(32 mm 6 mm)* Providing faucet openingis optionalLaundry tray
22、faucet openings*(number of openings optional)Indicates flat surrounding areafor faucet mounting2“(50.8 mm)4“(101.6 mm)2-1/2“(63 mm)* Providing faucet openingis optionalService sink faucet openings*Indicates flat surrounding areafor faucet mounting8“(203.2 mm)1-1/2“ 1/8“ dia.(38.1 mm 3.18 mm)2-1/2“(6
23、3 mm)3/8“ min. flat(9.53 mm)3/8“ min. flat(9.53 mm)2“ - 2-1/4“ dia.(50.80 mm - 57.15 mm)3-1/2“ - 4“ dia.(88.9 mm - 101.6 mm)Kitchen and/or bar sink outlets Bar sink outletsFigure 1 (continued)11IAPMO/ANSI Z124.6-20073/8“ min. flat(9.53 mm)Service sink outlets3“ - 3-1/4“ dia.(76.20 mm - 82.55 mm)3/8“
24、 min. flat(9.53 mm)Laundry tray outlets1-7/8 “ - 2-1/4“ dia.(47.63 mm - 57.15 mm)15/16“ nom.(23.81 mm)1-1/2“ dia. nom.(38.1 mm)Flat surface7/8“ nom.(22.23 mm)NOTE: Installer to provide throughhole in outletLaundry tray outlets1-1/2“ NPSMSingle hole punchingsNote: All single hole punchings shall be1-
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIIAPMOZ12462007PLASTICSINKS 塑料 PDF