ANSI ICEA P-45-482-2017 SHORT CIRCUIT PERFORMANCE OF METALLIC SHIELDS AND SHEATHS ON INSULATED CABLE.pdf
《ANSI ICEA P-45-482-2017 SHORT CIRCUIT PERFORMANCE OF METALLIC SHIELDS AND SHEATHS ON INSULATED CABLE.pdf》由会员分享,可在线阅读,更多相关《ANSI ICEA P-45-482-2017 SHORT CIRCUIT PERFORMANCE OF METALLIC SHIELDS AND SHEATHS ON INSULATED CABLE.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、ANSI/ICEA P-45-482-2017 Short Circuit Performance of Metallic Shields and Sheaths on Insulated Cable NOTICE AND DISCLAIMER The information in this publication was considered technically sound by the consensus of persons engaged in the development and approval of the document at the time it was devel
2、oped. Consensus does not necessarily mean that there is unanimous agreement among every person participating in the development of this document. The Insulated Cable Engineers Association. Inc. (ICEA) standards and guideline publications, of which the document contained herein is one, are developed
3、through a voluntary consensus standards development process. This process brings together persons who have an interest in the topic covered by this publication. While ICEA administers the process and establishes rules to promote fairness in the development of consensus, it does not independently tes
4、t, evaluate, or verify the accuracy or completeness of any information or the soundness of any judgements contained in its standards and guideline publications. ICEA disclaims liability for personal injury, property, or other damages of any nature whatsoever, whether special, indirect, consequential
5、, or compensatory, directly or indirectly resulting from the publication, use of, application, or reliance on this document. ICEA disclaims and makes no guaranty or warranty, expressed or implied, as to the accuracy or completeness of any information published herein, and disclaims and makes no warr
6、anty that the information in this document will fulfill any of your particular purposes or needs. ICEA does not undertake to guarantee the performance of any individual manufacturer or sellers products or services by virtue of this standard or guide. In publishing and making this document available,
7、 ICEA is not undertaking to render professional or other services for or on behalf of any person or entity, nor is ICEA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this document should rely on his or her own independent judgment or, as appropriate, seek
8、 the advice of a competent professional in determining the exercise of reasonable care in any given circumstances. Information and other standards on the topic covered by this publication may be available from other sources, which the user may wish to consult for additional views or information not
9、covered by this publication. ICEA has no power, nor does it undertake to police or enforce compliance with the contents of this document. ICEA does not certify, test, or inspect products, designs, or installations for safety or health purposes. Any certification or other statement of compliance with
10、 any health or safety-related information in this document shall not be attributable to ICEA and is solely the responsibility of the certifier or maker of the statement. ICEA P-45-482-2017 Page i CONTENTS Page Foreword . ii Section 1 GENERAL 1 1.1 SCOPE . 1 1.2 REFERENCES . 1 Section 2 FORMULAE AND
11、CALCULATIONS . 3 Section 3 Tabulated Parameters . 5 Table 1 Table 2 Table 3 Table 4 Table 5 Table 6 LIST OF TABLES Formulas for Determining Metallic Shield/Sheath Cross-sectional Area . . 4 Parameters for Use in Equations (1 ), (2) or (3) . 5 Values of T1, Approximate Shield or Sheath Operating Temp
12、erature, C at Various Conductor Temperatures 5 Values for Tz, Maximum Allowable Shield or Sheath Transient Temperature, C 6 M Values for Tz Temperature of 200 C . 6 M Values for Tz Temperature of 350 C . 7 Copyright 2017 by the Insulated Cable Engineers Association, Incorporated. ICEA P-45-482-2017
13、Page ii Foreword This publication discusses factors for consideration in approximating the operability of insulated and/or covered wire and cable under the influence of uninterrupted short circuit currents encountered as a result of cable or other equipment faults. The duration of such a fault is co
14、nsidered to be up to approximately 2 seconds. Calculation for single short circuits of longer durations will yield increasingly conservative results. The following items must be considered in order to estimate the short circuit performance of a specific circuit: 1. The magnitude and duration of the
15、fault current including any fault current division due to available conducting paths. 2. The capability of joints, terminations and other accessories in the affected circuit to withstand the thermal and mechanical stresses created by the fault. 3. The interaction between the faulting circuit and sur
16、rounding equipment, such as supports, ties and clamps. 4. The capability of the affected cable circuit, as installed, to withstand the electromagnetic forces created during the fault. 5. The maximum temperature that cable components can withstand without incurring damage due to heating caused by fau
17、lt current flow. 6. Damage to adjacent equipment due to arcing at the site of the fault. 7. For limitations imposed on the short-circuit current in the cable phase conductor see ICEA Publication P-32-382, Short Circuit Characteristics of Insulated Cable. An important simplifying assumption in the fo
18、rmula is the adiabatic nature of the heat generated, i.e., the duration of the fault is so short that all the heat developed by the fault current during this time is assumed to be completely contained within the sheath or shield. The amount of heat dissipated from the sheath or shield during continu
19、ous, single fault occurrences of relatively short duration is small. A significant amount of heat may be dissipated because of the relatively long cooling periods involved for faults interrupted and reestablished with automatic reclosing of circuit protective devices. A non-adiabatic calculation may
20、 be more suitable for these situations and for single. uninterrupted short circuits in excess of 2 seconds requiring close accuracy. Non-adiabatic calculation methods are described in several published works listed in Section 1.2 “References“. The formula (1) described in this publication is based o
21、n the thermal capacity of the metallic sheath/shield material and the transient temperature limit of the adjacent cable component materials. The quantity of heat contained in the metallic sheath/shield is that created by the fault current and is also a function of the temperature rise in the metalli
22、c sheath/shield. The magnitude of the temperature rise is the difference between the upper temperature of the cable material in contact with the sheath/shield and the operating temperature of the sheath/shield immediately prior to the initiation of the fault. The operating temperature of the sheath
23、or shield depends on the temperature of the conductor and the insulation thickness which is determined by the cable voltage rating. See Section 3, Table 3 for suggested estimated values. ICEA P-45-482-2017 Page iii The maximum transient temperature limits of the cable component materials are those w
24、hich cause no significant change in the materials. These limits were extrapolated from laboratory test data. Suggestions for improvements in this publication are welcome, and should be sent to the ICEA website http:/ Copyright 2017 by the Insulated Cable Engineers Association, Incorporated. ICEA P-4
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIICEAP454822017SHORTCIRCUITPERFORMANCEOFMETALLICSHIELDSANDSHEATHSONINSULATEDCABLEPDF

链接地址:http://www.mydoc123.com/p-434902.html