ASTM D494-2004(2010)e1 Standard Test Method for Acetone Extraction of Phenolic Molded or Laminated Products《酚醛模压或层压产品的丙酮萃取标准试验方法》.pdf
《ASTM D494-2004(2010)e1 Standard Test Method for Acetone Extraction of Phenolic Molded or Laminated Products《酚醛模压或层压产品的丙酮萃取标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D494-2004(2010)e1 Standard Test Method for Acetone Extraction of Phenolic Molded or Laminated Products《酚醛模压或层压产品的丙酮萃取标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D494 04 (Reapproved 2010)1Standard Test Method forAcetone Extraction of Phenolic Molded or LaminatedProducts1This standard is issued under the fixed designation D494; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、 year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEReapproved with editorial changes in July 2010.1. Scope*1.1 This test method covers the determination of the amounto
3、f acetone-soluble matter in molded or laminated phenolicproducts.1.2 The values stated in SI units are to be regarded asstandard.1.3 This standard does not purport to address all of thesafety problems, if any, associated with its use. It is theresponsibility of the user of this standard to establish
4、 appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1This test method is similar to ISO 308.2. Referenced Documents2.1 ASTM Standards:2D618 Practice for Conditioning Plastics for TestingD883 Terminology Relating to PlasticsE11 Specif
5、ication for Woven Wire Test Sieve Cloth and TestSievesE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method2.2 ISO Standards:ISO 308 PlasticsPhenolic moulding materialsDetermination of acetone-soluble matter (apparent resincontent of material in the unmould
6、ed state)3. Terminology3.1 All definitions are in accordance with TerminologyD883.4. Significance and Use4.1 For molded phenolic products, acetone extraction shallbe considered solely as a quantitative expression of a propertynormally associated with degree of cure. There is no demon-strably rigorou
7、s relation between the optimum mechanical andelectrical properties of a well-cured piece and the numericalvalue of the acetone test. The amount of acetone-soluble matteris affected by: (1) nature of resin and filler, (2) lubricant, (3)molding temperature, (4) length of cure, (5) thickness of thesect
8、ion from which sample is taken, (6) nature of molded piece,(7) technique used in molding, (8) distribution of fines in thematerial to be extracted, and (9) method of grinding thespecimen. These variations under some conditions will cause adifference of 3 to 4 % in acetone-extractable matter. For thi
9、sreason, the test method shall be used only as a comparative testfor measuring undercure.4.2 For laminated phenolic products, acetone extractionindicates change in stage of cure, change in resin content,change in type of resin used, presence of plasticizers or otheracetone-extractable addition agent
10、s, and is affected in generalby the same factors as stated in 6.15. Apparatus5.1 SievesThe set of sieves used shall consist of sievesNos. 40 (425-m) and 140 (106-m), with a cover andreceiving pan, conforming to the requirements of SpecificationE11.5.2 Extraction ApparatusThe apparatus may be of thet
11、ype shown in Fig. 1, or a Wiley-Richardson type, as shown inFig. 2. The former type is more suitable for use with smallelectric hot plates, while the latter is more suitable for use with1This test method is under the jurisdiction of ASTM Committee D20 on Plasticsand is the direct responsibility of S
12、ubcommittee D20.70 on Analytical Methods.Current edition approved July 1, 2010. Published October 2010. Originallyapproved in 1946. Last previous edition approved in 2004 as D494 - 04. DOI:10.1520/D0494-04R10E01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Cus
13、tomer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocke
14、n, PA 19428-2959, United States.oil or water baths. In either case, it shall be possible to controlthe temperature so that the rate of extraction can be regulatedaccurately.5.3 Drying DishesThe drying dishes shall be lightweightdishes, approximately 63.5 mm 212 in. in diameter and 38.1mm 112 in. in
15、height.6. Preparation of Sample6.1 PrecautionsIt is of utmost importance that extremecare shall be taken during the preparation of the sample forextraction. The sample shall be drillings if possible; however,if not possible, other suitable means of producing particlesequivalent to drillings shall be
16、 used. Drillings taken from alarge molded product shall be truly representative of allsections of the part in proper proportions. The drills forsampling shall be kept sharp and so operated that no undueheating of the material shall occur which will tend to precurethe material.NOTE 2If it is impracti
17、cable to obtain samples by drilling, the partsmay be broken up with a lathe, planer, milling machine, or a suitablegrinder. A mortar and pestle or a pebble mill is considered suitable as agrinder, provided no perceptible heating occurs during the grindingprocedure. A sharp file or rasp may be used f
18、or procuring the samplewhere the size or shape of the part is such that no other method is suitable.6.2 In any case, the particles of the sample shall be of thesmallest size practicable, so that they will pass through the No.40 sieve with the minimum of reworking or grinding. It isimportant in prepa
19、ring the sample that the smallest possiblevolume shall be obtained for a unit weight of the material.6.3 The sample shall be sieved through a No. 40 sieve andthat part which will not pass through shall be reground andblended with the original material passing the sieve. Afterassembling the Nos. 40 a
20、nd 140 sieves and the receiving pan,the sample shall be placed in the top sieve, the cover placed on,and the entire sample shall be resieved either by a mechanicalsieve shaker or hand sieving. If the hand-sieving method isused, the sieve shall be rotated with slight tapping, the periodof rotation be
21、ing 5 min.6.4 After sieving, the sample (that portion which has passedthrough the No. 40 sieve and has been retained on the No. 140sieve) shall be placed immediately in an airtight container toprevent absorption of moisture by the powder and the conse-quent error in results.7. Conditioning7.1 Condit
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD49420042010E1STANDARDTESTMETHODFORACETONEEXTRACTIONOFPHENOLICMOLDEDORLAMINATEDPRODUCTS 酚醛 模压 层压

链接地址:http://www.mydoc123.com/p-511796.html