ASTM D1652-2011 Standard Test Method for Epoxy Content of Epoxy Resins 《环氧树脂的环氧含量的标准试验方法》.pdf
《ASTM D1652-2011 Standard Test Method for Epoxy Content of Epoxy Resins 《环氧树脂的环氧含量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1652-2011 Standard Test Method for Epoxy Content of Epoxy Resins 《环氧树脂的环氧含量的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D1652 11Standard Test Method forEpoxy Content of Epoxy Resins1This standard is issued under the fixed designation D1652; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parenthese
2、s indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 This test method covers the procedure for manual andautomatic titration o
3、f epoxy resins for the quantitative deter-mination of the percent epoxide content from 0.1 26 %epoxide.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.3 This standard does not purport to address all of thesafety concerns,
4、 if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardstatements, see Section 6.2. Referenced Documents2.1 ASTM Standards
5、:2D1193 Specification for Reagent Water2.2 Other Documents:OSHA Regulations, 29 CFR paragraphs 1910.1000 and1910.120033. Summary of Test Method3.1 The resin is dissolved in a suitable solvent and theresulting solution is titrated with hydrogen bromide eitherdirectly or in situ. The hydrogen bromide
6、reacts stoichiometri-cally with epoxy groups to form bromohydrins; therefore, thequantity of acid consumed is a measure of the epoxy content.3.1.1 In the Manual Titration Method, the titration is withstandard perchloric acid in the presence of an excess oftetraethylammonium bromide. Hydrogen bromide
7、 generated insitu by the addition of perchloric acid to the quaternaryammonium halide rapidly opens the oxirane ring.3.1.2 In the Automatic Titration Method, the reaction ismeasuring the millivolt (MV) potential as perchloric acid isadded, which combines with the bromide to form the hydro-bromic aci
8、d, which reacts with the epoxide group. As thereaction progresses, the potential will gradually increase untilthe reaction nears completion at which point the potentialincreases very quickly. The titrator measures the rate of thereaction by calculating the change in potential between per-chloric aci
9、d addition increments. When the change in potentialbegins to decrease, the titrator determines that the titration iscomplete. The epoxide content is calculated using the reagentfactor entered by the user during standardization, the weight ofthe sample, and the volume of perchloric acid added duringt
10、itration.4. Significance and Use4.1 The epoxy content of epoxy resins is an importantvariable in determining their reactivity and the properties ofcoatings made from them. These test methods may be used todetermine the epoxy content of manufactured epoxy resins andconfirm the stated epoxy content of
11、 purchased epoxy resins.5. Reagents5.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specificati
12、ons are available.4Other grades may beused, provided it is first ascertained that the reagent is of1This test method is under the jurisdiction of ASTM Committee D01 on Paintand Related Coatings, Materials, and Applications and is the direct responsibility ofSubcommittee D01.33 on Polymers and Resins
13、.Current edition approved Nov. 1, 2011. Published January 2012. Originallyapproved in 1969. Last previous edition approved in 2004 as D1652 04. DOI:10.1520/D1652-11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Bo
14、ok of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from U.S. Government Printing Office Superintendent of Documents,732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401, http:/www.access.gpo.gov.4Reagent Chemicals, American Chem
15、ical Society Specifications, AmericanChemical Society, Washington, DC. For suggestions on the testing of reagents notlisted by the American Chemical Society, see Analar Standards for LaboratoryChemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeiaand National Formulary, U.S. Ph
16、armacopeial Convention, Inc. (USPC), Rockville,MD.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.sufficiently high purity to permit its use without lessening theaccur
17、acy of the determination.5.2 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean reagent water as definedby Type II of Specification D1193.6. Hazards6.1 Hydrogen bromide and glacial acetic acid are corrosive.Chlorobenzene and chloroform are considered hazardous.
18、 Inaddition to other precautions, take care to avoid inhalation andskin or eye contact with these chemicals. Use goggles or a faceshield, or both. Protect skin by use of suitable protectiveclothing. All specimen preparations shall be done in a wellventilated area, such as a fume hood.6.2 Consult cur
19、rent OSHA Regulations, Suppliers MaterialSafety Data Sheets, and local regulations for all materials usedin this test method.Manual Titration for Epoxy Content of Epoxy Resins7. Apparatus7.1 Buret, closed-reservoir type, bottom filling, 25-mL with110-mL division, or potentiometric automatic titrator
20、.7.2 Erlenmeyer Flasks, 100-mL, 250-mL, and 500-mL.7.3 Magnetic Stirrer, adjustable speed.7.4 Magnetic Stirring Bars, polytetrafluoroethylene (PTFE)coated.7.5 Pipets:7.5.1 Measuring Pipet, 25-mL.7.5.2 Volumetric Pipet, 50-mL.7.6 Volumetric Flask,1L.7.7 Bottle, 2 oz wide-mouth, or 100-mL disposable b
21、eaker,or equivalent.8. Reagents8.1 Glacial Acetic Acid (WarningSee Section 6).8.2 Tetraethylammonium Bromide, anhydrous crystals.8.3 Perchloric Acid (HClO4), 0.1 N in Glacial Acetic Acid(WarningSee Section 6).8.4 Acetic Anhydride (WarningSee Section 6).8.5 Methylene Chloride (WarningSee Section 6).8
22、.6 Crystal Violet Indicator, crystals.8.7 Potassium Acid Phthalate(KHC8H4O4) primary stan-dard grade.9. Reagent Preparation9.1 Tetraethylammonium Bromide Solution in Glacial Ace-tic Acid (WarningSee Section 6):9.1.1 Dissolve, with agitation at room temperature, 100 g oftetraethylammonium bromide in
23、400 mL of glacial acetic acid.9.2 Crystal Violet Indicator SolutionPrepare 0.1 % solu-tion of crystal violet indicator in glacial acetic acid(WarningsSee Section 6).10. Standardization of 0.1 N Perchloric Acid Reagent10.1 Standardization with Potassium Acid Phthalate:10.1.1 Dissolve 0.4 g of potassi
24、um acid phthalate, weighedaccurately to the nearest milligram, in 50 mL of glacial aceticacid, and add 6 to 8 drops of crystal violet indicator solution.Insert a clean stirring bar into the sample, and adjust themagnetic stirrer to effect solution. Continue agitation through-out the titration proced
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD16522011STANDARDTESTMETHODFOREPOXYCONTENTOFEPOXYRESINS 环氧树脂 含量 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-510214.html