ASTM C989 C989M-2016e1 Standard Specification for Slag Cement for Use in Concrete and Mortars《混凝土和砂浆中使用的矿渣水泥的标准规格》.pdf
《ASTM C989 C989M-2016e1 Standard Specification for Slag Cement for Use in Concrete and Mortars《混凝土和砂浆中使用的矿渣水泥的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM C989 C989M-2016e1 Standard Specification for Slag Cement for Use in Concrete and Mortars《混凝土和砂浆中使用的矿渣水泥的标准规格》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C989/C989M 161Standard Specification forSlag Cement for Use in Concrete and Mortars1This standard is issued under the fixed designation C989/C989M; the number immediately following the designation indicates the yearof original adoption or, in the case of revision, the year of last revis
2、ion. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1NOTEFootnote 4 was corrected editorially in March 201
3、7.1. Scope*1.1 This specification covers slag cement for use as acementitious material in concrete and mortar.NOTE 1The material described in this specification may be used forblending with portland cement to produce a cement meeting the require-ments of Specification C595/C595M or as a separate ing
4、redient inconcrete or mortar mixtures. The material may also be useful in a varietyof special grouts and mortars, and when used with an appropriateactivator, as the principal cementitious material in some applications.NOTE 2Information on technical aspects of the use of the materialdescribed in this
5、 specification is contained in Appendix X1, Appendix X2,and Appendix X3. More detailed information on that subject is containedin ACI 233R-03.21.2 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. Within the text, theinch-pound units are shown in brac
6、kets. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard. Values are stated in only SI units wheninch-pound units are not used in practice.1.
7、3 The text of this standard references notes and footnotesthat provide explanatory information. These notes and foot-notes (excluding those in tables) shall not be considered asrequirements of this standard.1.4 The following safety hazards caveat pertains only to thetest methods described in this sp
8、ecification. This standard doesnot purport to address all of the safety concerns, if any,associated with its use. It is the responsibility of the user of thisstandard to establish appropriate safety and health practicesand determine the applicability of regulatory limitations priorto use.2. Referenc
9、ed Documents2.1 ASTM Standards:3C109/C109M Test Method for Compressive Strength ofHydraulic Cement Mortars (Using 2-in. or 50-mm CubeSpecimens)C114 Test Methods for Chemical Analysis of HydraulicCementC125 Terminology Relating to Concrete and Concrete Ag-gregatesC150/C150M Specification for Portland
10、 CementC185 Test Method for Air Content of Hydraulic CementMortarC188 Test Method for Density of Hydraulic CementC204 Test Methods for Fineness of Hydraulic Cement byAir-Permeability ApparatusC430 Test Method for Fineness of Hydraulic Cement by the45-m (No. 325) SieveC452 Test Method for Potential E
11、xpansion of Portland-Cement Mortars Exposed to SulfateC465 Specification for Processing Additions for Use in theManufacture of Hydraulic CementsC595/C595M Specification for Blended Hydraulic CementsC670 Practice for Preparing Precision and Bias Statementsfor Test Methods for Construction MaterialsC1
12、012/C1012M Test Method for Length Change ofHydraulic-Cement Mortars Exposed to a Sulfate SolutionC1038/C1038M Test Method for Expansion of HydraulicCement Mortar Bars Stored in WaterC1437 Test Method for Flow of Hydraulic Cement MortarC1778 Guide for Reducing the Risk of Deleterious Alkali-Aggregate
13、 Reaction in Concrete1This specification is under the jurisdiction of ASTM Committee C09 onConcrete and Concrete Aggregates and is the direct responsibility of SubcommitteeC09.27 on Ground Slag.Current edition approved Dec. 15, 2016. Published January 2017. Originallyapproved in 1982. Last previous
14、edition approved in 2014 as C989/C989M 14.DOI: 10.1520/C0989_C0989M-16E01.2ACI 233R-03 Slag Cement in Concrete and Mortar. Available from AmericanConcrete Institute (ACI), P.O. Box 9094, Farmington Hills, MI 48333-9094,http:/www.concrete.org.3For referenced ASTM standards, visit the ASTM website, ww
15、w.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, P
16、O Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued
17、by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1D3665 Practice for Random Sampling of Construction Ma-terials3. Terminology3.1 DefinitionsFor definitions of terms used in this testmethod, refer to Terminology C125.4. Classification4.1 Slag cement is classified by perform
18、ance in the slagactivity test in three grades: Grade 80, Grade 100, and Grade120 (see Table 1).5. Ordering Information5.1 The purchaser shall specify the grade of slag cementdesired and the optional chemical or physical data to bereported.6. Additions6.1 Slag cement covered by this specification sha
19、ll containno additions except as follows:6.1.1 It is permissible to add calcium sulfate to slag cementprovided it has been demonstrated by Test Method C1038/C1038M that a test mixture will not develop expansion inwater exceeding 0.020 % at 14 days. In the test mixture, 50 %of the mass of portland ce
20、ment shall be replaced by an equalmass of slag cement. The portland cement used in the testmixture shall meet the requirements of Specification C150/C150M. When the manufacturer supplies cement under thisprovision, upon request, supporting data shall be supplied tothe purchaser.6.1.2 When processing
21、 additions are used in the manufac-ture of slag cement, the maximum amount used shall complywith the requirements of Specification C465 when tested usinga blend that is 50 % slag cement and 50 % portland cement bymass.7. Chemical Composition7.1 Slag cement shall conform to the chemical requirementsp
22、rescribed in Table 2.8. Physical Properties8.1 Slag cement shall conform to the physical requirementsof Table 1.9. Sampling9.1 The following sampling and testing procedures shall beused by the purchaser to verify compliance with this specifi-cation.NOTE 3Sulfur in granulated blast-furnace slag is pr
23、esent predomi-nantly as sulfide sulfur. In most cases, instrumental analyses, such as x-rayfluorescence, cannot differentiate sulfide sulfur from sulfate. Determineand report the sulfide sulfur content separately, and do not include it in theSO3calculations.9.2 Take random grab samples either from a
24、 delivery unit orat some point in the loading or unloading process so that nosample represents more than 115 Mg 125 tons (Note 4). Ifsamples are taken from rail cars or trucks, take at least twoseparate 2-kg 5-lb portions and thoroughly mix them toobtain a test sample (Note 5). Sample by removing ap
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC989C989M2016E1STANDARDSPECIFICATIONFORSLAGCEMENTFORUSEINCONCRETEANDMORTARS 混凝土 砂浆 使用 矿渣 水泥 标准 规格

链接地址:http://www.mydoc123.com/p-509061.html