ASTM C915-1979(2010) Standard Specification for Precast Reinforced Concrete Crib Wall Members《预应力混凝土框架挡土墙构件的标准规范》.pdf
《ASTM C915-1979(2010) Standard Specification for Precast Reinforced Concrete Crib Wall Members《预应力混凝土框架挡土墙构件的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM C915-1979(2010) Standard Specification for Precast Reinforced Concrete Crib Wall Members《预应力混凝土框架挡土墙构件的标准规范》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C915 79 (Reapproved 2010)Standard Specification forPrecast Reinforced Concrete Crib Wall Members1This standard is issued under the fixed designation C915; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of las
2、t revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers open- and closed-face precastreinforced concrete crib walls intended to act as earth-retainings
3、tructures or as protection against stream encroachment.NOTE 1This specification is a manufacturing and purchase specifica-tion only, with examples and suggestions for usage. Successful perfor-mance of this product depends on the proper selection and assembling ofmembers, proper foundation and bearin
4、g material, and consideration ofbackfill heights, backfill material, drainage, and other engineering andconstruction considerations. The purchaser of the crib wall membersspecified herein is cautioned that he must properly correlate the fieldrequirements with the members selected and provide adequat
5、e inspectionat the construction site.1.2 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only.2. Referenced Documents2.1 ASTM Standards:2A370 Test Methods and Definitions for Mechanical Testingof Steel ProductsA615/A615M Spe
6、cification for Deformed and PlainCarbon-Steel Bars for Concrete ReinforcementA616/A616M Specification for Rail-Steel Deformed andPlain Bars for Concrete Reinforcement3A617/A617M Specification for Axle-Steel Deformed andPlain Bars for Concrete Reinforcement3C31/C31M Practice for Making and Curing Con
7、crete TestSpecimens in the FieldC33 Specification for Concrete AggregatesC39/C39M Test Method for Compressive Strength of Cy-lindrical Concrete SpecimensC42/C42M Test Method for Obtaining and Testing DrilledCores and Sawed Beams of ConcreteC94/C94M Specification for Ready-Mixed ConcreteC150 Specific
8、ation for Portland CementC173/C173M Test Method for Air Content of FreshlyMixed Concrete by the Volumetric MethodC231 Test Method for Air Content of Freshly Mixed Con-crete by the Pressure MethodC260 Specification for Air-Entraining Admixtures for Con-creteC309 Specification for Liquid Membrane-Form
9、ing Com-pounds for Curing ConcreteC330 Specification for Lightweight Aggregates for Struc-tural ConcreteC494/C494M Specification for Chemical Admixtures forConcreteC595 Specification for Blended Hydraulic CementsC618 Specification for Coal Fly Ash and Raw or CalcinedNatural Pozzolan for Use in Concr
10、ete3. Classification3.1 Cribbing manufactured in accordance with this specifi-cation shall be of open- or closed-face design and shallconform to the standard designs shown in Figs. 1-4.4. Ordering Information4.1 Acceptability of the crib wall members in all crosssections and lengths produced in acco
11、rdance with Section 6shall be determined by the results of cylinder compression testsof the placed concrete and mill certificates for the reinforcingsteel and cement. A written statement, signed by the manufac-turer, shall verify that the cement, aggregate, admixtures, andreinforcing steel conform t
12、o the specifications for materials inSection 5 and that the preparation of equipment, mixing,conveying, placing, consolidating, and curing meet require-ments of the applicable standard specifications. The concretestrength as determined by the cylinder compression tests shallbe as specified in 6.3, a
13、nd the test method shall conform to the1This specification is under the jurisdiction ofASTM Committee C27 on PrecastConcrete Products and is the direct responsibility of Subcommittee C27.20 onArchitectural and Structural Products.Current edition approved July 1, 2010. Published August 2010. Last pre
14、viousedition approved in 2002 as C915 79 (2002). DOI: 10.1520/C0915-79R10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe
15、ASTM website.3Withdrawn.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.requirements of Test Method C39/C39M. The manufacturersstatement shall also certify adherence to tolerance dimensionsof Section 9.4.2 Acceptability of the concre
16、te strength of completedcribbing produced in accordance with Section 6 may also bedetermined by compressive tests of concrete cores in accor-dance with Test Method C42/C42M.5. Materials5.1 CementPortland cement shall conform to the require-ments of Specification C150 or shall be portland blast-furna
17、ceslag cement or portland-pozzolan cement conforming to therequirements of Specification C595.5.2 AggregatesAggregates shall conform to SpecificationC33 or C330. The nominal maximum size aggregate shall notbe greater than34 in. (19.0 mm).5.3 AdmixturesAir-entraining admixtures shall conformto Specif
18、ication C260. Chemical admixtures shall conform toSpecification C494/C494M. Fly ash or other pozzolanic ad-mixtures shall conform to the requirements of SpecificationC618.5.4 WaterWater used for curing, washing aggregates, andmixing concrete shall be free of oils, organic materials, andother substan
19、ces that may be deleterious to concrete or steel; itshould not contain concentrations of chlorides in excess of1000 ppm or sulfates in excess of 1000 ppm.5.4.1 If water of higher chloride content is used by reason ofnonavailability of water of recommended quality, the manu-facturer must obtain appro
20、val from the user.5.5 Steel ReinforcementSteel reinforcement shall consistof bars conforming to Specifications A615/A615M, A616/A616M,orA617/A617M.NOTE 1Surface drainage should not be permitted to flow directly against the face of the cribbing.NOTE 2Walls should be separated into 96-ft sections by t
21、he provision of double rows of headers.NOTE 3In using these typical sections for designing walls of intermediate height, the drawing should be read from the top down until the desiredheight is reached. Base details are repeated for intermediate heights.NOTE 4In areas of aggressive environment, Type
22、II cement or protective coatings, or both, may need to be used to avoid deterioration of the walls.NOTE 5Metric Conversion: 1 ft = 304.8 1 in. = 25.4 mm 1 lb = 0.453592 kg 1 ft3= 0.028317 m3FIG. 1 Open-Faced Concrete Crib WallC915 79 (2010)26. Design6.1 Precast concrete crib wall members shall confo
23、rm todetails and dimensions prescribed in Figs. 1-4, subject to theprovisions of this section and Section 10.6.2 ReinforcementMinimum reinforcement shall be asshown in Fig. 2 and Fig. 4 and shall be Grade 40 or 60.6.3 ConcreteConcrete shall have a minimum design com-pressive strength of 4000 psi (28
24、 MPa) in 28 days.6.4 Concrete CoverThe minimum concrete cover over thereinforcement shall be 114 in. (32 mm).6.5 Air EntrainmentUnless otherwise specified by thepurchaser, all concrete shall have an air content of 612 6 112% as measured by Test Method C173/C173M or C231.7. Manufacture7.1 Certificati
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC91519792010STANDARDSPECIFICATIONFORPRECASTREINFORCEDCONCRETECRIBWALLMEMBERS 预应力 混凝土 框架 挡土墙 构件 标准规范

链接地址:http://www.mydoc123.com/p-508781.html