《ASTM C536-1983(2009) Standard Test Method for Continuity of Coatings in Glassed Steel Equipment by Electrical Testing《在锌和镉表面非铬酸涂层试验的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM C536-1983(2009) Standard Test Method for Continuity of Coatings in Glassed Steel Equipment by Electrical Testing《在锌和镉表面非铬酸涂层试验的标准实施规程》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 536 83 (Reapproved 2009)Standard Test Method forContinuity of Coatings in Glassed Steel Equipment byElectrical Testing1This standard is issued under the fixed designation C 536; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the detection of discontinuitiesin the glass coating of glassed steel eq
3、uipment where suchdiscontinuities would result in early failure due to the attack ofthe chemical contents of the vessel on the metal substrate. It isapplicable to (1) provide a manufacturing and inspection test ofglassed-steel equipment designed for relatively mild, low-temperature corrosive service
4、, and (2) the field testing ofsimilar equipment used in more severely corrosive environ-ment.NOTE 1A manufacturing test method for the latter type of equipmentis described in Test Method C 537.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included
5、 in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to us
6、e.2. Referenced Document2.1 ASTM Standards:2C 537 Test Method for Reliability of Glass Coatings onGlassed Steel Reaction Equipment by High Voltage3. Summary of Test Method3.1 The test method consists essentially of grounding themetal structure of the equipment being tested to the ground sideof a vol
7、tage generator and sweeping the surface of the glasswith a suitable probe electrically connected to the other side ofthe generator. Wherever a discontinuity exists, a discharge willgive a positive indication that such a discontinuity exists. Thevoltage is set at 5000 V in order to show existing disc
8、ontinui-ties without breaking through the existing glass coating. Abuilt-in current limiting device ensures electrical safety for theoperator.4. Significance and Use4.1 This test method is designed to detect existing discon-tinuities in the glass coating of glassed steel equipment whilemaintaining a
9、 voltage low enough as to be unlikely to causebreakdown of the coating. The test is adaptable for manufac-turing inspection in the processing of equipment and for fielduse to find existing defects which can be “plugged” or repairedbefore serious damage is done to the equipment. As a means ofpositive
10、 detection, it is applicable to process studies, qualitycontrol, or specification.5. Definition5.1 glassed steel (glass-lined steel or glass-coated steel)designations generally applied to a class of porcelain enamelsthat have high resistance to chemical attack at elevatedtemperatures and pressures.6
11、. Interferences6.1 Since the test method is electrical, it is necessary to havea good ground connection between the instrument and themetal substrate of the equipment being tested. It is alsonecessary that the surfaces of the glass be reasonably clean anddry. A wet surface will conduct enough voltag
12、e to any exposedmetal to give an indication of a “contact” over a large areainstead of at a specific area of discontinuity. Such a capacitancedischarge can be distinguished from a true failure by extendingover a large area instead of at local spots that could beidentified and marked for repair.7. Ap
13、paratus37.1 The test apparatus comprises a voltage stabilizing trans-former, a step-up transformer, a current-limiting resistance, avoltmeter and pilot light, along with a suitably insulated cableand probe handle equipped with interchangeable wire brush-type and point electrodes (see Fig. 1 for a sc
14、hematic wiringdiagram). The current output is limited to 2.5 mA. The wire1This test method is under the jurisdiction ofASTM Committee B08 on Metallicand Inorganic Coatings and is the direct responsibility of Subcommittee B08.12 onMaterials for Porcelain Enamel and Ceramic-Metal Systems.Current editi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC53619832009STANDARDTESTMETHODFORCONTINUITYOFCOATINGSINGLASSEDSTEELEQUIPMENTBYELECTRICALTESTING 表面

链接地址:http://www.mydoc123.com/p-466948.html