ASTM C459-1997(2006) Standard Test Methods for Asbestos-Cement Flat Products《石棉水泥板制品的标准试验方法》.pdf
《ASTM C459-1997(2006) Standard Test Methods for Asbestos-Cement Flat Products《石棉水泥板制品的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C459-1997(2006) Standard Test Methods for Asbestos-Cement Flat Products《石棉水泥板制品的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 459 97 (Reapproved 2006)Standard Test Methods forAsbestos-Cement Flat Products1This standard is issued under the fixed designation C 459; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A n
2、umber in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 These test methods cover only asbestos-cement flatshee
3、ts, roofing shingles, siding shingles, and clapboards.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.3 WarningBreathing of asbestos dust is hazardous.Asbestos and asbestos products present demonstrated healthrisks for us
4、ers and for those with whom they come into contact.In addition to other precautions, when working with asbestos-cement products, minimize the dust that results. For informa-tion on the safe use of chrysoltile asbestos, refer to “Safe Useof Chrysotile Asbestos: A Manual on Preventive and ControlMeasu
5、res.”21.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For a sp
6、ecificsafety hazard, see 1.3.2. Referenced Documents2.1 ASTM Standards:3E 177 Practice for Use of the Terms Precision and Bias inASTM Test Methods3. Terminology3.1 Definitions:3.1.1 deflectionthe linear distance that a test specimenbends at the center from no load to maximum breaking loadwhen loaded
7、 as a beam with the load applied equally andsimultaneously at both one-third points of the span.3.1.2 flexural strengththe average breaking load in new-tons (or lbf) of dried specimens loaded as simple beams on aspan of 254 mm (10 in.) with the load applied equally andsimultaneously at both one-thir
8、d points of the span.4. Sampling4.1 From each shipment or fraction thereof representing aproduct of the same kind, a number of sheets or units shall beselected at random. Table 1 and Table 2 show the number ofsheets or units to be selected from shipments of various sizes.5. Preparation of Test Speci
9、mens5.1 Flat SheetsCut a pair of specimens, each 6 6116 in.(152 6 1.6 mm) in width and 12 6116 in. (305 6 1.6 mm) inlength, from the interior area of each sample sheet in such amanner that no edge of a specimen is less than 3 in. (76 mm)from the original edges of the sheet. The longer dimension ofon
10、e of the specimens of each pair shall be parallel to the lengthof the sheet (that is, parallel with the fiber lay), and that of theother shall be at right angles to it. (WarningSee 1.3.)5.2 Roofing Shingles, Siding Shingles, and ClapboardsCut a single specimen 6 6116 in. (152 6 1.6 mm) in width and1
11、2 6116 in. (305 6 1.6 mm) in length from each unit. Cut onehalf of the specimens in such a manner that the 12-in.(304.8-mm) dimension of each specimen is parallel to one edgeof the shingle or clapboard unit; cut one half of the specimensat a right angle thereto. Where the shingle or clapboard unitsh
12、ave one dimension less than 12 in., cut all specimens with the12-in. dimension of each specimen parallel to the long dimen-sion of the shingle or clapboard unit.1These test methods are under the jurisdiction of ASTM Committee C17 onFiber-Reinforced Cement Products and are the direct responsibility o
13、f Subcommit-tee C17.03 on Asbestos-Cement Sheet Products and Accessories.Current edition approved June 1, 2006. Published June 2006. Originallyapproved in 1960. Last previous edition approved in 2002 as C 459 97 (2002)e1.2Available from The Asbestos Institute, http:/ referenced ASTM standards, visit
14、 the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.TABLE 2 Sampling Plan for Roofing Shingles, Siding Shingles,and ClapboardsNumber of Unitsin Shipme
15、ntNumber of Unitsto Be Selectedas SamplesA8 000 and under 108 001 to 64 000 2064 001 to 216 000 30216 001 to 512 000 40512 001 to 1 000 000 50AAdditional units may be taken at the discretion of the inspector.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 194
16、28-2959, United States.5.3 Do not test cracked or otherwise damaged specimens,but obtain substitute specimens.6. Flexural Strength and Deflection Tests6.1 Significance and Use:6.1.1 Flexural StrengthThis is a routine test. The valuesrecorded are applicable only to the product being tested. Thebreaki
17、ng loads specified should be maintained or exceeded toensure successful use.6.1.2 DeflectionThis is not commonly a routine test, but isa reference or referee test. The values recorded are not relative,but are applicable only to the product being tested. The greaterthe deflection, provided the flexur
18、al strength is satisfactory, thelower the breakage hazard will be in use. The limits chosen inthe material specifications are arbitrary, and are based uponexperience.6.2 Procedure:6.2.1 Dry each specimen to constant weight in a ventilatedoven at a temperature of 100 to 105C (212 to 220F), and coolto
19、 room temperature in a desiccator or desiccator-type cabinet.Record the dry weight of each cooled specimen. Determine theflexural strength of each specimen by placing the specimen onsupports that cannot exert longitudinal constraint rocker-typebearing edges or rollers witha3mm(18-in.) minimum and 13
20、mm (12-in.) maximum radius and applying the load equallyand simultaneously at both one-third points of the span throughsimilar edges, bearing against the finished surface of thespecimen. The test span shall be 254 6 1.6 mm (10 6116 in.),and the load lines and ups shall be parallel. Mount a dialmicro
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC45919972006STANDARDTESTMETHODSFORASBESTOSCEMENTFLATPRODUCTS 石棉 水泥板 制品 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-466638.html